My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1360
>
2300 - Underground Storage Tank Program
>
PR0231486
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 11:09:28 AM
Creation date
11/4/2018 5:09:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231486
PE
2381
FACILITY_ID
FA0009157
FACILITY_NAME
McDowell & Davis Towing & Auto Repair
STREET_NUMBER
1360
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22706108
CURRENT_STATUS
02
SITE_LOCATION
1360 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ESCALON\1360\PR0231486\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
4/4/2013 8:00:00 AM
QuestysRecordID
93891
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA — ,�'t6 c t <br /> STATE WATER RESOURCES CONTROL BOARD ,ems e <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B 30 �, o <br /> ro <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED SfTE <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ s TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: /3 G O TS ; 0 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY F UNKNOWN <br /> A. OWNER'S TANK I.D.# B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAWYEAR) 6 D. TANK CAPACITY IN GALLONS: S OO <br /> II.TANK CONTENTS IFA-1 IS MARKED.COMPLETE ITEM C. <br /> OTOR VEHICLE FUEL ❑ 4 OIL B. C. tAUNLEADED e REGULAR 3 DIESEL ❑ g AVIATION GAS <br /> A. 6 GASAHOL <br /> ❑ 2 PETROLEUM ❑ 80 FlAPTY 1 PRODUCT ❑ 1bPREMIUMUNLEADED 8 5 JET FUEL ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED 99 OTHER (DESCRIBE IN ITEM D.BELOW) <br /> D. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.S: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.ANDC.ANOALLTHATAPPLIES INBOXD <br /> A. TYPEOF ❑ 1 OOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEMSINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ e POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (PAmaryTank) ❑ 9 BRONZE ❑ 10 GALVANUED STEEL UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC UNNG <br /> C.INTERIOR ❑ 5 GLASS LINING ❑ 8 UNLINED e1-95 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES_ NO— <br /> D.CORROSION ❑ I POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE UNKNOWN ❑ N OTHER <br /> IV.PIPING INFORMATION CIRCLE A IFASOVEGROUNDOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U I SUCTION A PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A& 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U I RARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 8 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A fW36 UNKNOWN A U N OTHER <br /> D. LEAK DETECTION I OMATIC LINE LEAK DETECTOR Q..9-tNETIGHTNESSTESTING ❑ J INCT) NG ❑ N OTHER <br /> V.TANK LEAK DETECTIO—NI�� <br /> F-1 �� ••-VE1 VISUAL CHECK NTORY RECONCILIATION ❑ 3 VAPOR MONITORING❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br /> K TESTING ❑ 7 INTERSTMALMONRORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ N OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED OUANTITY OF 3.WAS TANK FILLED WITH VES ❑ NO❑ <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> IvwxrEOasicnZE <br /> 77 <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW ��22 <br /> COUNTY# JURISDICTION# FACILITY# PJ TANK# µl L.OJo4J LJ <br /> STATE I.D.# <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> FORM B (9-90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. IP <br /> Fgi0NI8At <br />
The URL can be used to link to this page
Your browser does not support the video tag.