My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON BELLOTA
>
17407
>
2300 - Underground Storage Tank Program
>
PR0501540
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 9:48:23 AM
Creation date
11/4/2018 5:11:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0501540
PE
2381
FACILITY_ID
FA0005140
FACILITY_NAME
ESCALON FEED & SUPPLY
STREET_NUMBER
17407
Direction
S
STREET_NAME
ESCALON BELLOTA
STREET_TYPE
RD
City
ESCALON
Zip
95320
APN
22502014
CURRENT_STATUS
02
SITE_LOCATION
17407 S ESCALON BELLOTA RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ESCALON BELLOTA\17407\PR0501540\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
4/5/2013 8:00:00 AM
QuestysRecordID
84121
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION ® b. <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. _ <br /> MARK ONLY F-11 NEW PERMIT ❑3 RENEWALPERMR CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED I <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: b �[Y FARM TANK-YES❑ NO EL� Z <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY 1 <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: (/ <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> W <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. EU440TOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. I UNLEADED ❑ 2 LEADED ❑3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OILODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ BO EMPTY [-]95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF A / <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.# /17 C.A.S.#: / V <br /> All. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOK A,B,C.a D <br /> A TYPE ❑ i DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR UNER 1KNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMEM ❑99 OTHER <br /> ❑ 1 STEBUIRON 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 MEL CLAD W/RBERGUSS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑B 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9BRONZE ❑ fO GALVANIZED STEEL UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR F-11 RUBBER LINED ❑2 ALKYD LINING F-13 EPDXY LINING F-14 PHENOLIC LINING <br /> LINING ❑5 CUSS LINING ❑6 UNLINED KNOWN <br /> ❑ IS UNING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHLENE WRAP ❑2 TARORASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE UNKNOWN 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IFABOVEGROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER (J' U <br /> B.CONSTRUCTION A U i SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL Yfjp5 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 3 VADOBE WELLS P f 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> N ' P S 6 PRECISION TESTING P 8 7 PRESSURE TESTING P 1 NONE P 8 95 UNKNOWN P 8 W OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(M YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 6 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY IDN TANK ID# <br /> EN = = IrInlaI31 -fli <br /> CURRENT LOCAL AGENCY FACILITY IDN APPROVED BY NAME NEN LTH AREA CODE <br /> L <br /> R PERMIT APPROVAL DATE PERM EKPIR ON DATE <br /> PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORMB(3-7-88) THIS FORM MUST BE ACCOMPANI YAFACILITTISREAPPLICATION, FORM'A',UNLESS ACURRENT FORMA' HASBEENFILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.