Laserfiche WebLink
STATE OF CALIFORNIA "� <br /> STATE WATER RESOURCES CONTROL BOARD 05 <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B "�°8 e° <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON E <br /> ONE ITEM ❑ 2 INTERIM PERMIT F-14 AMENDED PERMIT ❑ 8 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK 1.0.♦ S. MANUFACTURED BY: <br /> C. DATE INSTALLED(MOMAY/YEAR) . D. TANK CAPACITY IN GALLONS: a <br /> If.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A_ �1 MOTOR VEHICLE FUEL ❑ 6 OIL B. ���----yBR� C, ib REGUfM UNLEADED ❑ 3 DIESEL ❑ 6 AVIATIONGAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ ib PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ED 85 UNKNOWN 2 WASTE ❑ to MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> 2 LEADED ❑ 99 OTHER(DESCRIBE8I REMD.BELOW) <br /> D. IF(Al)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A S.# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (po-"Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL 5 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 8 UNUNED 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? S_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN O 99 OTHER <br /> E.SPILL AND OVERFILL,BB:. SPILL CONTAINMENT INSTALLED(YEAR) OQkRRU.PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE YES NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A(%iE5 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U B CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION vvillUNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION 1 MECCTOR IME LENK 2 WE TIGI11M;35 3 COY9NMdlE Mi 1!IIIAL 4 EIECIRONC UNE 5 Al1iGMA11C PWP <br /> ❑ OETECiGR ❑ 1E811NG ❑ MOH WJW ❑ LEV(9EIECfOR ❑ EHUTWWN 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 REECCOUAL NCIUATIONQRY ❑ 3 VADOZEMONITORING ❑ 4 GAUGING AUTOMATIC TANK [:]5 GROUND MONITORING WATER ❑ 6 ANNUALTESTING <br /> ❑ 7 <br /> MONITORING INTERSTITIAL ❑ B SIR ❑ 9 WANK WEEKLYMANUAL ❑10 MONTHLY TANK g5 UNIOJOWN ❑99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATED DATE LAST USED(MC/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES [:D NO❑ <br /> SUBSTANCE REMAINING GALLONS I INERTMATERIAL7 <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> (PRWTED a SIGNAN <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# DO-7,9TANK <br /> STATE I.D.# D T I olt I7 I re <br /> PERMIT NUMBER OERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PL7LE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE-' -9RGROUND STORAGE TANK REGULATIONS <br /> FORM (6-95) 1� <br />