My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14000
>
2300 - Underground Storage Tank Program
>
PR0231631
>
COMPLIANCE INFO_1992 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:32 AM
Creation date
11/4/2018 5:25:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992 - 2006
RECORD_ID
PR0231631
PE
2361
FACILITY_ID
FA0000091
STREET_NUMBER
14000
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
14000 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\HWY 88\14000\PR0231631\COMPLIANCE INFO 1992 - 2006 .PDF
QuestysFileName
COMPLIANCE INFO 1992 - 2006
QuestysRecordDate
3/16/2017 4:23:12 PM
QuestysRecordID
3355446
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 <br /> F. In-Tank Gauging I SIR Equipment: 0 Check this box if tank gauging is used only for inventory control. <br /> ❑ Check this box if no tank gauginv or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is use erPorm leak detection monitoring. <br /> C fete the followin checklist: <br /> ❑ Yes Q No- Has all input wiring been inspected for per entry and termination,including testing for ground faults? <br /> D Yes I D Noy I Were all tank gaagmg probes vipzffiy inspected fordamage and residue btdldup? <br /> D Yes D NoY Was accuracy of system pEdauct level readings tested? <br /> ❑ Yes ❑ No* Was accuracy of syeern water level readings tested? <br /> 11 Yes ❑ Nor Were all ppbft reinstalled properly? <br /> D Yes LI No' Were items on We equipment manufacturer's maintenance checklist completed? <br /> a in the se=akDeteaors <br /> ow,describe how and when these deficiencies were or win be corrected. <br /> G. Line (LLD): ❑ Check this box if LLDs are not installed. <br /> Com le the following checklist: <br /> es D No* For equipment start-up or annual equipment certification, was a leak simulated to verify I.LD performance? <br /> O NIA (Check all altar apply) Simulared leak rate:,%eg_p-hD 0.t g ph: D U g p h. <br /> Yes ❑ No* Were all LLDs omfirmed operational and accurate within regulatory requirements" <br /> ❑ Nem Was the testing apparatus properly calibrated? <br /> Yes ❑ Ne For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> ❑ NIA <br /> ❑ Yes u7 Nor For electronic LLAs,does the turbine automatically shut offif the LLD detects a leak? <br /> ❑ NIA <br /> ❑ Yes ❑ No' For electronic LLDs,rites the turbine automatically shun off if any portion of the monitoring system is disabled <br /> a NIA or diwuanected? <br /> D Yes D No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions <br /> D NIA or fails a test? <br /> Q Yes ❑ No* For electronic LLDs,have all accessible wiring connections been vitmally inspected? <br /> ❑ NIA <br /> Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected_ <br /> H. Comments: <br /> Page 3 of 3 03/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.