My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14000
>
2300 - Underground Storage Tank Program
>
PR0231631
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:27 AM
Creation date
11/4/2018 5:26:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231631
PE
2361
FACILITY_ID
FA0000091
STREET_NUMBER
14000
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
14000 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\HWY 88\14000\PR0231631\BILLING 2010- 2015 .PDF
QuestysFileName
BILLING 2010- 2015
QuestysRecordDate
5/18/2017 9:56:03 PM
QuestysRecordID
3388301
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
*ED IED PROGRAM CONSOLIDATED FO <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN — Pae 2 of 2) <br /> VI. UNDER DISPENSER CONTAINMENT (UDC) MONITORING (Check all <br /> that apply) <br /> UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> ® L CONTINUOUS ELECTRONIC MONITORING ® 2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE 490-540,. <br /> ❑ 4.NO DISPENSERS ❑ 99.OTHER(Specify) 490-54b. <br /> LEAK MONITOR MANUFACTURER.Veeder-Root 490-57 MODEL#:TLS-350 496am <br /> LEAK SENSOR MANUFACTURER: OPW/Bravo 450-57' MODEL#(S):Float&Chain/208 Sensors 49458. <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ® a.YES ❑ b.NO 49059. <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 49w- <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490,61• <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. ® a.YES [Ib.NO 49x61. <br /> __.._—______________- <br /> UDC CONSTRUCTION IS: ® 1.SINGLE WALL ❑ 2.DOUBLE WALL 490,3. <br /> IF DOUBLE WALL: 490,44% <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: Cl a.LIQUID ❑ b.PRESSURE ❑ c.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ❑ a.YES ❑ b.NO 490,44 <br /> VII. PERIODIC SYSTEM TESTING <br /> 1.ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 4`0-65. <br /> LEAK T D MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 23 M 1644,1 <br /> ® 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 49046. <br /> ® 3.SPILL BUCKETS ARE TESTED ANNUALLY. 490'67, <br /> VIII. RECORD KEEPING <br /> The following monitoring/maintenance records are kept for this facility: 490.69. <br /> ® a.ALARM LOGS ❑ b.VISUAL INSPECTION RECORDS ❑ c.TANK INTEGRITY TESTING RESULTS <br /> ❑ d.SIR TESTING RESULTS(and supporting documentation records) ❑ e.TANK GAUGING RESULTS(and supporting documentation records) <br /> ❑ f.ATG TESTING RESULTS(and supporting documentation records) ❑ g.CORROSION PROTECTION 60-DAY LOGS <br /> ® <br /> It.EQUIPMENT MAINTENANCE AND CALIBRATION RECORDS <br /> IX. TRAINING <br /> Personnel with UST monitoring responsibilities arc familiar with all of the following documents relevant to their job duties: 490694. <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apptv) <br /> ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) 490,96 <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) 490690. <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 49069& <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 49069.. <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND 490,9t <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 490698, <br /> ❑ OTHER(Specify): 49M9h. <br /> 490,91. <br /> This facility has a-Designated UST Operator'who has passed the California UST System Operator Exam administered by the International Cade Council 490,70. <br /> (ICC). The "Designated UST Operator'will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 <br /> days of hire.This training will include,but is not limited to,the following: <br /> • Operation of the UST systems in a manner consistent with the facility's bat management practices. <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br /> • The facility employee's role with regard to spills and overfills as specified in the facility's UST Response Plan. <br /> r Name(s)of contact person(s)for emergencies and monitoring alarm. <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. 49071. <br /> Overfill mehanical flapper set at 95% <br /> XI. PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that: 1.)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered <br /> b�this_plan occurs;�all conditions that indicate a possible release are ms estigated_anil ill monitorrds arcmaintained pmpe ly.. <br /> THE FOLLOWING PERSON(S)ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAINTENANCE: <br /> NAME, Mohammad Aftal 490-72. TITLE:Store Manager 490-73, <br /> NAME: George Sisson 4961 TITLE:Zone Manager 49075. <br /> The Designated UST Operator shall perform a monthly visual inspection of the facility,provide a report to die owner/operator,mrd inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION: I certify that the information pXovided herein is true and accurate to the hest of my knowledge. <br /> APPLICANT SIGNATURE: � � DATE- 49077. <br /> 04/21/10 <br /> REPRESENMiG,0 lj� goree.r ®2,Facihl">u or❑3.a0rhor¢M R.murotaliee o[(hrrmr 49076. <br /> APPLICANT NAME(print): 490,78 APPLICANT TITLE: 49x79' <br /> Paul Chevalier Maintenance Manager <br /> UPCF UST-D(12/2007)-314 www.unidoes.org <br />