My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007- 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14000
>
2300 - Underground Storage Tank Program
>
PR0231631
>
COMPLIANCE INFO_2007- 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:32 AM
Creation date
11/4/2018 5:26:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007- 2008
RECORD_ID
PR0231631
PE
2361
FACILITY_ID
FA0000091
STREET_NUMBER
14000
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
14000 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\HWY 88\14000\PR0231631\COMPLIANCE INFO 2007- 2008.PDF
QuestysFileName
COMPLIANCE INFO 2007- 2008
QuestysRecordDate
5/18/2017 10:06:39 PM
QuestysRecordID
3388455
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
06/11/2008 WED 8: 15 FAX 2094683433 SJC EHD 01003/007 <br /> 4 • • <br /> • UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORINGPLAN (Page2of2) <br /> VI.UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> 1. UPC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 4�54' <br /> Ur 49040 <br /> 1.CONTINUOUS ELECTRONIC MONITORING ❑2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE <br /> 114.NO DISPENSERS ❑99.OTHER(Scecify): _ <br /> PANEL MANUFACTURER: U 9d90as MODEL aY: Lf f �/ 490w. <br /> LEAK SENSOR MANUFACTURER: V MODEL M(S): 2 490.58 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS a.YES ❑b.NO 490.59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN NYU ❑b.NO 0040. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. jg!YES ❑b.NO 49061 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER GKYES ❑b.NO 49D-62 <br /> 2.UDC CONSTRUCTION IS i.SINGLE-WALLED ❑2.DOUBLE-WALLED 4900 <br /> .IF DOUBLE WALLED: 490,644 <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑1.LIQUID ❑2.PRESSURE [13.VACUUM _ <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑a.YES ❑b.NO 490'64b <br /> VII.PERIODIC SYSTEM TESTING <br /> 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCBD 490.65. <br /> LEAK D MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.(23 C_CR 52644.1) <br /> V2. ECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 49066 <br /> SPILL BUCKETS ARE TESTED ANNUALLY. 090.6 <br /> VIII.RECORDKEEPING <br /> rIlowing monitoring/maintenance records are kept for this facility; ���- <br /> The <br /> 49o-6s. ❑Visual Inspection Records 4% b Wjf nk integrity testing results 4%4sc <br /> WIR testing results(and supporting documentation records). 4W.60e Qr Tank gauging results(and supporting documentation records). 490.6eo <br /> [}J Testing results(and supporting documentation records).49a6er ❑ Corrosion Protection 60-day logs 4X488 <br /> JE Equipment maintenance and calibration records. 490.68h <br /> IX,TRAINING <br /> • Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 4o49a <br /> REPE$ENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> EVEN HIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)~bOPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)49o-694 <br /> e'SQALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 4%696 <br /> [r-3a"�CALIFORNIA UNDERGROUND STORAGE TANK LAW 49x694 <br /> ryJ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR 'TANK OWNERS - MANUAL AND <br /> TATISTICAL INVENTORY RECONCILIATION"490.69r <br /> S WRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490498 <br /> OTHER(Specify):m69k t469t <br /> This is <br /> has a"Designated UST Operator"who has passed the Califomia UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"wilt vain facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> Operation of the UST systems in a manner consistent with the facility's best management practices <br /> D The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> ➢ The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> D Names of contact person(s)for emergencies and monitoring alarms.490.70 <br /> X, COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.4%.71 <br /> OVo2 G�VGL /t/G<yH^ �6/aG G/ /�/�f /L S6% 6V <br /> XL PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that 1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs;2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained property. <br /> The follow�gyerson(s)oe responsible for performing the monitoring end equipment maintenance: <br /> NAME UL C Vi3L2/'2 Oso-n TIME ilJ N G- 490.73 <br /> NAME 490.74 TITLE 490.95 <br /> The Designated Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII.OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to thebest of my knowledge, <br /> APPLICA SIGNATURE15� 490-76 DATE: 490-77 <br /> • � 3/y/o <br /> APPLICANT NAME(print): 490"98 APPLICANT TITLE: 4Y0'19 <br /> 1'1fitn- C et/�G2 <br /> UPCF UST-D(12/2007)3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.