Laserfiche WebLink
NOSINIL1I MMCATION L kBOR-ATORY ANALYSIS <br /> yu i 097412NATLF <br /> TANK TANK TPH-G I TPH-D j BTX&E CL HC TOTAL MBE NTB3, NLTAa% PCB <br /> COY-ENTS 8015 8015 j 8020 8C 10 LEAD 8020 T3AFree <br /> 60 1P rd , 82-0 <br /> 8260 8260 460 82W 7u 8260 ) or <br /> AA ( 8080 <br /> 82 <br /> LEADED GAS X i x I I % X <br /> LNL GAS X I x I I x <br /> x x j <br /> X. <br /> DIESEL , <br /> KEROSENE I X X X <br /> ji <br /> �t UYK=FUEL X X :C X i x <br /> PROD. CIL X X I x <br /> CHiOR. R X i x <br /> SOLVE ITS <br /> NORCHLOR �' n <br /> SOLVENTS X X <br /> I <br /> ,k ASTE% X <br /> I <br /> USED OIL X I X X X I � I i X :[ <br /> All analysis medtods are the designated EPA methods descri3ed;n EPA SW 3a5. Third Edition. Those methods not fownd in <br /> SW 846 are 5pee,ncatly noted below. Rzfer to the 'SIYRCB LETT Field Manual% Appandix D (B),Tiolc 3a on page AN for <br /> minian;m de:ecrion liraita tor motor vehicle A el f9asoline aid diesel). Refer to "Tri-Regional 3odzd Staff Recotncendadons far <br /> initial Evaluation and Iavestigadcn Cf UST 13" for the waste and motor oil minim=detecrlon lisps. <br /> Detection Limits that remain below the 31CL. STLC or Allowable Limit of the contaminant in question will be accepted, <br /> however laboratory sball utilize the most conservative metbod. ' <br /> LABOlLAT-ORY ANALYSES TERM„^''OLOGY, <br /> 7?H-G Total pencteurs Hydrocarbon, Gasoline. G'-'FID(5030) 8015 mod or GC!"S 3260 <br /> 'j?F.D Taal pccraleum Hydrocaroon, Close.. GCFC (1550). 5015 mod or GONIS 3260 <br /> Brix&E Bcnzene.Toiucne.Xylene 3c Ethyl 3enzera. C/PID gG20 or GCGMS 8260 <br /> CL HC Chloriratad Hydrocarbon, GC.'HSD 8010, GGhLS 8240 or 3260 <br /> TOTAL LEAD Tota:ieid.AA 7420, AA 7921 or ICP•A_S 6010 <br /> OXYGE.NA115 MTBE, ETB'e.TA.YIE.DIM.do MA GCNS 8257 !For MTBL scroen x v you rnac use 5020) <br /> METALS ICA?or,1A Inluctively Coupled?lasera Abaco:Emitaidd Spectromcty 6C10 or Atomic Abscrprton Stxctromet-"v 7C00- <br /> Metals- Cadmium, Chromium III and N7,Lzsd, Zinc and`ric'sal. <br /> .CB poly:Yforinated Biphenyls. G0NIS Ki M or 8 80 <br /> GC-FIC Gas Ctlrematogtaphy,F.a=e Ionization nott-tion <br /> Msthod 3050 Acid digestion <br /> Method 3W Soahla sample pr..paracon <br /> Method 3550 Sonication wrnp'e preoaratbn,eztracdon method <br /> ufethcd 5030 purge and trap sample preparation <br /> QA/QC Q'aa1Ly Assura.1=!Qwiity Control <br /> Notes: To avoid false positive defection of beazerc. ter--n&-ft=salvena are to be used. Fused raninary columns are 3re!- cd to packea <br /> ='lutnns:a packed co umr.may be used as a"first out'with "dirty"samples or once the hydrecarhans have been characterized sod proper <br /> QA!QC is fa o'xed. r-fereix to the 6}0 series xause the <br /> Fcr drwi in:waw sources.EFA recommends Cta:crs 50o serer for volatile organic should be u.:d in p - <br /> deteetiaa Arrau bre lower and die Q,44C 1s 0 tier. SarnpleS exnibiarg any ;evel of heavy metal cd-raatiradoo may req'_re Former analysi1. <br /> pEE•E`D rr ontmans Bolding those samples omni d!sPolal is indicated <br /> EH 23 ?6 iA sed 06!;3i9T, Pagc 8 <br />