My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
18662
>
2300 - Underground Storage Tank Program
>
PR0505356
>
COMPLIANCE INFO_2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:32 AM
Creation date
11/4/2018 5:30:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0505356
PE
2361
FACILITY_ID
FA0006733
FACILITY_NAME
GEORGES BP MINI MART
STREET_NUMBER
18662
Direction
N
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
18662 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\HWY 88\18662\PR0505356\COMPLIANCE INFO 2010 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
2/1/2018 7:40:19 PM
QuestysRecordID
3779163
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> GEORGES BP MINI MART 209 727-3064 March 03 2015 <br /> Facility Address: CER S ID: <br /> 18662 N HWY 88 LOCKEFORD CA 95237 10182137 <br /> Inspection Contact: Title: Phone: <br /> Ru finder Padda o erator -97 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION -Operating Permit 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> Inspection Photos Sampling Ru inder Padda operator <br /> Service Technician Onsite Exp.Date: Designated Operator: Exp.Date: <br /> David Winkler 03/03/2016 Alex Jabbari 10/03/2016 <br /> Service Technician Manufacturer's Training <br /> Veeder Root,02/10/16; VMI 11/10/15 <br /> R=California ode of egulations H = eanri antl afeiy Coae CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate ❑V o R a COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V ❑R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted o V ❑R o COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current ❑V c R ❑COS <br /> 105 HSC 25286(c) Current BOE number not submitted o V ❑R ❑COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD o V o R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V a R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notrfy the EHD 48 hours prior to conducting testing o V o R o COS <br /> 109 CCR 2637 Failed to test secondary containment o V a R o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days o V ❑R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V o R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually a V a R a COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ❑V ❑R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down o V o R o COS <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days ❑V o R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V o R o COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1 000'of a public well o V o R o COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test o V o R ❑COS <br /> 119 CCR 2644.1(s)(5) Failed to submit ELD test results within 60 days o V o R o COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after a V o R o COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V ❑R o COS <br /> 122 HSC 25299 Documents were falsified or misrepresented o V �R �COS <br /> 123 CCR 2661 Permit to repair UST system not obtained a V o R a COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification o V o R o COS <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V ❑R o COS <br /> Received by Inspector: Phone: Date: <br /> (initial): ARTS VELOSO, Senior REHS (209) 468-3453 03/03/2015 <br /> Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.