Laserfiche WebLink
ISD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL ACCEPT HIGH ORVR: <br /> ALL:DEGRD COLLECT FAIL DISABLED <br /> OUTPUT RELAY SETUP I ALL:FLOW COLLECT FAIL ISD HOSE TABLE <br /> - R 4:DIESEL ID FP FL HL AA RR <br /> TYPE: ----------- - ----------- <br /> R 1 '87 STANDARD 01 01 01 02 01 UU <br /> TYPE: ( NORMALLY CLOSED 02 02 02 02 01 UU <br /> STANDARD 03 03 03 02 02 UU <br /> NORMALLY CLOSED TANK N: 4 04 04 04 02 02 UU <br /> TANK t<: 1 05 05 05 02 03 UU <br /> 06 06 06 02 03 UU <br /> IN-TANK ALARMS 07 07 07 02 04 UU <br /> IN-TANK ALARMS T 4[LOW PRODUCT ALARM 08 08 08 02 04 UU <br /> T 1 :LOW PRODUCT ALARM LIQUID SENSOR ALMS <br /> LIQUID SENSOR ALMS L 4:FUEL ALARM ISD AIRFLOW METER MAP <br /> L 1 :F'UEL ALARM L 4:SENSOR OUT ALARM ID SERIAL NUM LABEL <br /> L 1 :SENSOR OUT ALARM L 4:SHOR'T ALARM - -1 2296--------,------- <br /> L 1 :SHORT ALARM 1 22960 DI1-2 F <br /> 2 58056 DISP F 3-4 F <br /> ISD SITE ALARMS 3 30415 DISP 5-6 F <br /> ISD GROSS PRES FAIL 4 18981 DISF 7-8 F <br /> ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL ISD FUEL GRADE HOSE MAP <br /> ISD HOSE ALARMS 1 2 3 4 <br /> ALL:GROSS COLLECT FAIL FP MHH MHH MHH MHH AA <br /> ------------------------- <br /> ALL:DEGRD COLLECT FAIL 01 001 201 101 U U 1 <br /> ALL:FLOW COLLECT FAIL SMARTSENSOR SETUP 02 002 202 102 U U 1 <br /> 03 003 203 103 U U 2 <br /> R 2:89 04 004 204 104 U U 2 <br /> TYPE: s 1 :DISP 1-2 FLOWMETER 05 005 205 105 U U 3 <br /> STANDARD CATEGORY AIR FLOW METER 06 006 206 106 U U 3 <br /> NORMALLY CLOSED 07 007 207 107 U U 4 <br /> TANK #: . 2 ' s 2:DISP 3-4 FLOWMETER 08 008 208 108 U U 4 <br /> CATEGORY AIR FLOW METER 09 O D U U U U U U 0 <br /> 10 0 U U U U U U U 0 <br /> IN-TANK ALARMS s 3:DISP 5-6 FLOWMETER <br /> T 2:LOW PRODUCT ALARM CATEGORY AIR FLOW METER LABEL-TABLE <br /> LIQUID SENSOR'ALMS s 4:DISP 7-8 FLOWMETER <br /> L -:FUEL ALARMCATEGORY AIR FLOW METER 1 : UNASSIGNED <br /> L -:SENSOR OUT ALARM 2: BLEND3 <br /> L '-:SHORT ALARM s 5:PRESSER SEN. 3: REGULAR <br /> CATEGORY VAPOR PRESSURE 4: MID GRADE <br /> ISD SITE ALARMS 5: PREMIUM <br /> ISD GROSS PRES FAIL 6: GOLD <br /> ISD DEGRD PRES FAIL 7: BRONZE <br /> ISD VAPOR LEAK FAIL 8: SILVER <br /> 9: BLEND2 <br /> ISD HOSE ALARMS 10: BLEND4 <br /> ALL:GROSS COLLECT FAIL. <br /> ALL:DEGRD COLLECT FAIL <br /> ALL:FLOW COLLECT FAIL <br /> R 3:91 <br /> TYPE: <br /> STANDARD <br /> NORMALLY CLOSED EVR.'ISD SETUP <br /> TANK 0: 3 PMC SETUP <br /> IN-TANK ALARMS EVR TYPE: VACUUM ASSIST PMC VERSION: 01 .02 <br /> T '3:LOW PRODUCT ALARM VACUUM ASSIST TYPE <br /> T 3:HIGH WATER WARNING HEALY VAC �VIAAPOR PROCESSOR TYPE <br /> ONE <br /> LIQUID SENSOR ALMS NOZZLE A/L RANGE <br /> L 3:FUEL ALARM MAX: 1 .15 MIN: 0.95 PROCESSOR CONTROL LEVEL: <br /> L 3:SENSOR OUT ALARM NONE <br /> L 3:SHORT ALARM VAPOR PROCESSOR TYPE <br /> NONE <br /> ISD SITE ALARMS <br /> ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL ANALYSIS TIMES <br /> ISD VAPOR LEAK FAIL TIME: MINUTES:AM 1 <br />