Laserfiche WebLink
i . . . i <br /> SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 E. Main St. • Stockton, CA 95202-3029 • Phone(209)468-3420 <br /> Donna Heran,R.E.H.S.,Director <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> Program Permit Permit <br /> Record to Number Program Code and Description Valid <br /> PRO518165 PT0011882 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 1/112011 To 12/3112011 <br /> Hazardous Waste Generator Program: <br /> In order to maintain t t.to-pperate,Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20,Chap.6.5,Art.2-13, <br /> Sec.261q0-et .q,_and Title 22, Cali o 'a Code of Regulations,Chap.20, <br /> '------- ----t CaVd-- ------ -------- ----- ----'---------------------------------'-------------------------------- <br /> 2300-UN ERGROUND STORAGE TANK FACILITY 1/112011 To 1213112011 <br /> oder round Stor a <br /> California Health and Safety Code,Div.20,Chap.6.7 and Title 23,California Code_of Regulations, Chap, 16__ <br /> P/E Tank 4 Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection <br /> 2362 1 390005053560505357 PT0007940 10,000 DIESEL Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 2 390005053560505358 PT0007937 6,000 MIDGRADE UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 3 390005053560505359 PT0007938 4,000 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 4 390005053560505360 PT0007939 10,000 REGULAR UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> DQE ID#:..44036334 <br /> Underground Storage Tank Permit CondiCions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions. <br /> 2) In order to maintain the operating permit,the owner and operator shag comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions <br /> established by San Joaquin Comity. <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. <br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EfID)and are considererd UST Permit Conditions. The approved <br /> monitoring,response,and plot plans shall be maintained onsite with the pest. <br /> 5) The Permittee shall comply will)the monitoring procedures referenced inthis permit. <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and <br /> provide documentation ofsuch servicing to this office. <br /> 7) In the event of a spill,leak,or other unauthorized release,the Pernitee shall comply with the requirements of Title 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan. <br /> 8) Written records ofall monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was <br /> performed. <br /> 9) The SED shall be notified of any change in ownership or operation of the UST system within 30 days of such change. <br /> 10) Upon any change in equipment,design or operation of the UST system(including change m tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> revocation. <br /> 1.1) Construction,repair and/or removal permits are requited from the EHD prior many change,repair or removal of UST system equipment. <br /> 12) The Pennihee shall submit an annual-report docmmenting compliance with the UST Permit Conditions within 30 days of the date of the issuance of this permit. <br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency. <br /> 14) A"Conditional'Permit may be revoked if corrections specified on the inspection repos are not completed by the date(s) indicated, <br /> ----------------------------"-'-------._-------------------------------------------_._____ --------- ----- -------- ----------- __._____ -------------- _.____-._______. <br /> PERMITS TO OPERATE may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s)Valid only for: PADDA, RUPINDER/SODHI,HOSHIAN <br /> DBA: GEORGE'S BP MINI MART <br /> Tank Owner: GALATSATOS, GEORGE <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> GEORGES BP MINI MART FacilitylD FA0006733 <br /> Regulated Facility: <br /> 18662 N HWY 88 Account ID AR0009174 <br /> LOCKEFORD CA 95237 Issued 21412011 <br /> 7028.rpt <br />