�. City of Stockton o TL# 394-0192-01 <br /> t <br /> September 16, 1994 'I'r Page 13 <br /> :Ir <br />' Samples will be delivered to Twining's �cheiAstry laboratory in <br /> Fresno, California. Analytical methods with corresponding method <br /> detection limits and copies of the chain-of-custody records will be <br /> provided in the technical report. <br /> A-7 Laboratory Quality Assurance ualit :. Control (QA/OC)-: This <br /> section describes the laboratory QA/QC Procedures which will be <br /> followed during the analyses of the soil and groundwater samples by <br /> Twining's analytical chemistry laboratory,'. <br /> The QA/QC procedures will be developed to minimize outside <br /> interferences during analyses for each ;sample. The laboratory <br /> manager will be in charge of creating and aintaining the program. <br /> In general, QA/QC proposed for this investigation are summarized as <br /> { follows: <br /> ■, Analytical instruments are serviced on ', a regular basis to <br /> monitor accurate calibration; !# <br /> ■ Organic-free water will be monitoredIdai y for quality; <br /> ■ Gas chromatographs will be calibrate' dally; <br /> ■ Method blanks will be tested to check whether the glassware <br /> and reagents are free of interference from chemicals that <br /> would invalidate the analyses; and 'I <br /> I'f ■ Standards will be prepared using the applicable reference <br /> materials. <br /> ' Ifi 4 <br /> A-8 standard ORerating Procedures for Using Photoionization <br /> Detector(PID) and/or Drager® Tubes: The PID will be calibrated in <br /> accordance with the manufacture's recommendations prior to use in <br /> the field. Upon arrival p ri al at the project s.xte, ,the PID will be used <br /> to monitor concentrations background g r tions of, organic vapors in the <br /> atmosphere at the site. The background con'centrations will be <br /> 1 measured in a location upwind and removed �:as possible from sources <br /> of organic vapors on the site. When background concentrations of <br /> organic vapors register as 110. 0" on the PTD, subsequent readings of <br /> "0. 0" registered from samples tested in the field will be recorded <br /> as "ND" (not detected) . When background concentrations of organic <br /> vapors register at some quantity above 1101; 011 , �� subsequent readings <br /> +, registered from samples tested in the field at or below this value <br /> 1 will be recorded as "B/G" (background) . <br /> The Drager® tubes used will be consistent vithlthe type of analyte <br /> which is suspected as being present on the project site (i.e. for <br /> gasoline product use the benzene tube, for" diesel product use the <br /> petrol-hydrocarbon tube, etc. ) . <br /> i <br /> �,l <br />