Laserfiche WebLink
Sao r/ <br /> SAN J(DAQLJI N LOCAL_ I =AJ .TH DI =FZI CT <br /> _ MININUM VERIFICATION LABORATORY ANALYSIS <br /> p�a <br /> j TANK CONTENTS TPH-G ITPH-D TEPH BTX&E CL HC TEL EDB , <br /> Waste Product ' GC-FID GC-FIDI (3550) 1 (8020) 1 (8010) ! (D 0 H S) ; (ICP-METALS. (8270)� <br /> (5030) 1 (5030) (3540)_ ; (8240) ' _ �--AES) + (8080) <br /> LEADED GASOLINE X X X 1 X j <br /> U4 GASOLINE X I X i --- ---� — <br /> DIESEL j I X X I j <br /> KEROSENE I X I I X <br /> —�_— <br /> ( UNKNOWN FUEL —� X —i—�X X I X X <br /> OIL X I X <br /> II -- ------- ---- <br /> CHLOR. SOLVENTS I X I X I I <br /> NONQ-QAR. SOLVTS I X - —1�— <br /> I <br /> WASTE/USED OIL X X X X X <br /> MINIMUM VERIFICATION LABORATORY ANALYSES TERMINOLOGY <br /> The following listing of laboratory analyses abbreviations is provided as a guide so that <br /> terminology used will be more familiar. All analyses methods are designated EPA methods as <br /> described in EPA SW 846, Third Edition. Those methods not found in SW 846, are <br /> specifically noted. <br /> TPH G Total Petroleum Hydrocarbon, Gasoline <br /> Total Petroleum Hydrocarbon, Diesel <br /> TEWL Total Extractable Petroleum Hydrocarbon (8015) <br /> 6 (8020) Benzene, Toluene, Xylene S Ethyl Benzene (8020) <br /> 10 OR 8240 Chlorinated Hydrocarbon 8010 or 8240 <br /> (DOHS-LUFT) Tetraethyl Lead (DOHS-LUFT) <br /> CRIME IDOHS-Ay 1803) Ethylene dibromide (DOHS-AB 1803) <br /> Gas Chromatography Flame Ionization Detector <br /> ICP-AES OR AA Inductively Coupled Plasma Atomic Emission Spectrometry or Atomic <br /> Absorption Spectrometry <br /> Method 5030 Purge and Trap Sample Preparation <br /> Method 3550 Sonication Sample Preparation <br /> Method 3540 Soxhlet Sample Preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene, benzene-free solvents are to be used. <br /> Fused capillary columns are preferred to packed columns; a packed column may be used as a <br /> first cutff with fodirty samples or once the hydrocarbons have been characterized and <br /> proper QA/QC is llowed. <br /> For Drinking Water Sources EPA recommends that the 500 series for volatile <br /> organics be used in preference to Ehe 600 series because the detection limits are lover and <br /> the QA/QC is better. <br /> :r:��.r.+•r:aswsnarrmctt•!a^...as'P.+aWa. .. KaFn�+'IJ.a_'LK4z'�.FAii iT1`n1F.77§���4NCS+ki'.A+3?F¢a:�':Rv-5f'"1::A.F55F�CiH'FY.7i i.x10.'.:..4'�AL�F.'€k`.; :5+^..4"_:7:T..., <br />