My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT
>
145
>
2300 - Underground Storage Tank Program
>
PR0504311
>
REMOVAL_2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2019 2:22:12 PM
Creation date
11/5/2018 8:51:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2003
RECORD_ID
PR0504311
PE
2381
FACILITY_ID
FA0006161
FACILITY_NAME
MORADA SHOPPING CENTER
STREET_NUMBER
145
Direction
N
STREET_NAME
GRANT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
145 N GRANT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT\145\PR0504311\REMOVAL 2003.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` %001 �Grg'n d Storage Tank Removal Report <br /> 730 E.Channel Street,Stockton,CA <br /> Page 2 <br /> The soil in the excavation generally consisted of dark to medium brown clay. There were no significant <br /> lateral variations in the soil conditions through the extent of the excavation, suggesting that the original <br /> excavation to install the UST was likely backfilled with native material. Soil staining and petroleum <br /> ` odors were noted in the excavation and excavated soil. Groundwater was not encountered in the <br /> excavation. Photographs #4 through #6 show the tank pit. Upon removal of the UST, product started to <br /> drain from the UST. A small pool of product formed at the southern end of the excavation. The pool of <br /> material and soil beneath it were removed and separated from the other soil from the excavation. <br /> ` Photograph#5 shows the small pool of product. <br /> The site is the former location of the Stockton Metropolitan Transit District (1945-1975). The UST had <br /> 6' not been used for many years. Observation of the exterior of the UST indicated that the tank was in poor <br /> condition. Corrosion and holes were noted on the UST. The UST and associated piping were hauled off- <br /> site by West Coast Equipment to Turlock,California. <br /> Approximately 85 feet of piping associated with the UST, previously removed USTs, a dispenser, and a <br /> diesel filter were also removed. The removed piping was observed to generally be in good condition with <br /> only minor corrosion.During the removal of some of the piping extending north from the diesel filter and <br /> east to the dispenser, some diesel product was released from the dispenser. Photograph #7 shows the <br /> dispenser area after the diesel product was released. The excavated soil from the dispenser area was <br /> .. segregated from the other soil.The removed piping was transported off-site by OES. <br /> 3.0 SOIL SAMPLING <br /> ` Following removal of the UST, soil samples were collected from locations directed by Ms. Abate of the <br /> SJCEHD. Soil sample locations are shown in Figure 2 in Appendix A. <br /> ` • Soil sample "NorthTK-8"' was collected from approximately two feet beneath the northern end of <br /> the UST, approximately eight feet below ground surface (bgs). <br /> • Soil sample "SouthTK-8"' was collected from approximately two feet beneath the southern end of <br /> the UST,approximately eight feet bgs. <br /> • Soil sample "Dispenser" was collected from approximately two feet beneath the dispenser, <br /> approximately three feet bgs. <br /> • Soil sample "Filter" was collected from approximately two feet beneath the diesel filter, <br /> approximately three feet bgs. <br /> • Soil sample "Trench-N" was collected from approximately two feet beneath the piping and located <br /> approximately 20 feet north of the building, approximately three feet bgs. <br /> • Soil sample "Trench-E" was collected from approximately two feet beneath the piping and located <br /> approximately 25 feet north and 16 feet west of the building, approximately three feet bgs. <br /> • Soil samples "Stockpile-N" and "Stockpile-S" were collected from the soil excavated from the UST <br /> removal. <br /> The soil samples collected from beneath the UST excavation,piping,dispenser, and diesel were obtained <br /> by manually driving a clean brass tube into soil brought to the surface in the backhoe bucket. The soil <br /> samples collected from the stockpile were obtained by manually driving a clean brass tube into the soil <br /> �. stockpile. The soil samples were immediately sealed with Teflon sheeting, capped, labeled, and placed <br /> in a cooler chilled with ice. The soil samples were delivered under chain-of-custody procedures to Argon <br /> Laboratories of Ceres,California, for analyses. <br /> r <br /> �/� COeNNDODr���0::R�„ <br />
The URL can be used to link to this page
Your browser does not support the video tag.