My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1988 PLAN
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
INSTALL_1988 PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 3:27:58 PM
Creation date
11/5/2018 8:54:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1988 PLAN
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\INSTALL PLAN 1988.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k <br /> 6, Foundation Excavation: Excavate for foundation as shown D. Workmanship <br /> on drawings. Form all surfaces except where earth forms 1 . Concrete footings: <br /> are specifically approved by the Owner. Trim excavation walls and a. Place reinforcing bars as designated on drawings with cover, laps <br /> bottoms to smooth, uniform line and grade, Provide sumps, drains and bends as indicated. Maintain a minimum clear distance of 3 <br /> and pumps as necessary to keep excavation dry at all times. Remove inches between reinforcing and bottom and sides of excavation <br /> soft soots and unsuitable material as directed by the Owner and and fasten bars securely in place to prevent displacement. g <br /> shore and brace excavation in accordance with OSHA requirements b. Cleaning: Remove all debris and loose earth from forms . Stand „j <br /> and as necessary to prevent caving and erosion. ing water shall be removed from forms before pouring conrete. : <br /> 7, Earth Forms: Where earth forms are approved, excavate foundations c . Wetting: Moisten earth and wood form surfaces lust prior to <br /> to neat line and grade shown on drawings. Trim walls and bottom placing concrete . <br /> smooth and uniform. Where walls tend to slough, overexcavate , d. Inspection: Notify Architect for inspection of footing excava- ` <br /> form and brace. tion and reinforcing before casting any concrete . When possible <br /> give 48 hours notice for all inspections. <br /> 8. After prime coat and paint binder has been approved, spread and e. Pipe and Conduit : Electrical conduit only may be placed in <br /> compact asphalt concrete paving t0 compacted thickness Shown on footings where SUCK conduit SIZe and IOC2tlon is approved by the '71, <br /> drawings in accordance with CSS Section 39. Architect . Place conduit and pipe running through or beneath <br /> 9, Defective Base and Paving: Where the paving is not placed t0 ootings as indicated. Do not embed aluminum conduit in concrete <br /> ARCHITECTS <br /> correct grade, or is otherwise judged to be defective, remove unless corrosion protection is provided, <br /> and replace at no cost to the Owner, f . Construction Joints: Form construction joints only in locations <br /> shown or approved. Key and form all joints as indicated. Clean <br /> 02800 SITE IMPROVEMENTS and roughen joint surfaces before casting adjacent concrete. <br /> g. Vibrating: Compact concrete immediately after placing with <br /> 810 Irrigation Systems - This section Shown on Landscape Drawings. mechanical vibrators, taking care not to mar form surfaces. <br /> N. Curing: Keep all exposed concrete surfaces continuously moist <br /> for at least 7 days after placing. or spray with an approved <br /> 02900 LANDSCAPING curing compound. 940 TYLER STREET. 15FUDIO 23 'i <br /> This Section shown on Landscape Drawings. 2. Concrete slabs on grade: <br /> `f <br /> a. Reinforcement: Place accurately where shown. 1302 i (415)682-0302l <br /> b. Wetting: Moisten wood form surfaces just prior to placing <br /> concrete. <br /> d, Placing: Place concrete In one continuous operation for each <br /> area cast and vibrate or spade to a dense uniform consistency <br /> DIVISION 3 — Concrete free of void spaces and rock pockets. <br /> e. Construction Joints: Conform to details shown. No panel size <br /> 03200 CONCRETE REINFORCEMENT greater than 501 sq. ft. or greater than 20 feet In any dimension. <br /> anddalait the site, Report,K% <br /> ernxs discrepancies or questions to <br /> 210 Reinforcing Steel r. Screeding: Screed to a true surface with a maximum deviation of # <br /> A. Codes and Standards x <br /> 114 Inch in an/ 10 foot length. constructiongark forconfrictP <br /> and <br /> 1. Uniform Building Code, 1982 Edition. <br /> 't <br /> 2. ACI Standard 318-83, "Building Code Requlrements for Reinforced e. Curing: Cure slab Witt, white polyethylene film or sprayed permisstom <br /> Concrete. ' oRmbrane, applied imme(lately after finish operations. Cure 7 R <br /> B. Materials: days maximum. Seal edges of polyethylene film. .. <br /> 1 . Reinforcement: <br /> a. Bars: Conform to ASTM A 615-72, Grade 40 s, Wncrete temperature during piacement shall not exceed 90 degrees F. <br /> b. Wire Fabric: Conform to ASTM A 185. or be below 40 degrees F. FOOD CJS LIQUOR 37 ' <br /> 2• Tying Wire: ASTM A 82-72 , 4• Place concrete in a manlier which avoids segregation. <br /> C. Workmanship. Steel Fabrication and Placement: Place steel , supporting Luncrete shall not be used beyond (1) hour of adding mixing water. T <br /> and wiring in accordance with Reference Standards. Bar reinforcing Additional mixing water; is not allowed after initial batching. 15 West G r a ntline <br /> shall be wire tied at all intersections and at all splices. <br /> Tracy, Ca <br /> 03300 CAST - IN-?LACE-CONCRETE <br /> 310 structural Concrete the Customer Co '. <br /> A. Codes and Standards <br /> 1 . Uniform Building Code. 1982 Edition, P O. Box 886 Benicia, Gq <br /> 2. ACI Standard 301-83. "Specifications for Structural Concrete fo)r <br /> Buildings. " I <br /> B. Materials 3 <br /> 1 . Portland Cement: Type II conforming to ASTM C 150, low alkali . <br /> 2. Aggregate: <br /> a. Course Aggregate: Conform to ASTM C 33, Refer t0 Paragrap)h C <br /> for maximum size. <br /> b. Fine Aggregate: Conform to ASTM C 33, SHEET TITLE <br /> SPECIFICATIONS I <br /> S. Wetel: Clean and free from deleterious tefioUS amounts Of fOfel9n matter . <br /> 4. Sand: Conform to ASTM C33. <br /> 5. Curing Materials: ASTM C 309 for compounds and white polyethylene <br /> ,i <br /> film. Clear or black not acceptable, <br /> C. Concrete Design , <br /> REVISIONS DATE <br /> 1 , Minimum 28-day ultimate compressive strength: 2500 psi ; maxlmium <br /> aggregate size 3/4"; and maximum slump: 40; transit-mixed concrete: <br /> 'i <br /> conform to ASTM C 94 <br /> 2. Weighmaster' s certificate required for all concrete. <br /> 5. All concrete shall be reinforced unless noted, "Not Reinforced <br /> 4. Contractor shall submit a mix design for approval for each tyoie of <br /> concrete used stamped and signed by a licensed testing lab or icivil Dace Drawn By <br /> engineer. Mix designs shall list all elements used by weight, : <br /> Job No. Checked By <br /> including any admixtures. i <br /> SHEET <br /> D <br /> IL <br /> O <br /> 1 <br /> OF SHEETS <br /> i <br />