Laserfiche WebLink
RETAIL AUTOMATION COMPUTER NOTES SURFACE MOUNTED CABLE <br />ON BACK ROOM WALLS <br />1. Workstation Tobte - <br />G7M <br />2. Retail Automation Computer (CPU) <br />3. Monitor [GAS <br />4. Keyboard �COMROLLER}" <br />5. Printer <br />6. Battery <br />7. Router <br />8. Hub <br />9. Modem <br />10. Handheld Cradle <br />11. Optional fan and task light (served by auxiliary duplex outlet) <br />12. New duplex receptacle which receives the following plugs; <br />(1) Battery; (2) Future; <br />13. Computer battery receptacle will receive the following plugs. See Retail <br />Automaton Workstation elevation this sheet. <br />(1) CPU; (2) Cradle; (3) Monitor; (4) Power Strip (Supplied by NCR installer) <br />14. The computer will receive four (4) 100 foot category 5 Systimax LAN cables (3 for registers; <br />one future) run from sales area registers through a one inch roncuit (see <br />Wiring Diagram this sheet) and terminate at a four outlet cable jack with a 4 <br />outlet faceplate which meets category 5 transmission requirements as <br />exemplified by Model MPS10OBH type with corresponding face plate. <br />Register LAN cables will sub up out of the floor at each register locaVan. See <br />Sheet E-1. <br />15. The romputer will receive the following additional data cables. <br />(1) Cheyenne Money Order Cable- Batman cable; (2) Future lottery, safe cables. <br />Data conduit will hove RS232 and DB25 connectors. There are two (2) 1/0 <br />cables from the computer 25 DBA connectors for money order machine. <br />(1 ) :(2) <br />Cables will run form the ISP workstation through a one (1) inch conduit <br />termination at the sales area backwall (see Wiring Diagram this sheet). <br />16. Telephone lines Telephone wiring from telephone panel to dual RJI I <br />receptacle by telephone subcontractor. Location for receptacle is marked by <br />electrical subcontractor. Line #1 is telephone voice line from telephone board. <br />Line #2 is a dedicated computer modem line. <br />Final interface connection'to DMARC board is by telephone contractor. <br />Telephone contractor will label the DMARC with appropriate LEC and IXC <br />circuit carriers. Lobel line #1 and line #2 at the ISR <br />17. Auxiliary duplex receptacle for fon and light only. <br />18. One inch PVC in wall for data cables. See notes 14 and 15 above and wiring <br />diagram on this sheet. <br />19. Cheyenne Money Order Machine. See note 15 above and Wiring Diagram <br />this sheet. <br />7.0. Point of Sale (POS) register, <br />21. Floor mounted 4 plex receptacle with one receptacle accessible ( others <br />covered with outlet caps similar or equal to Levitan No.12777.) Receptacle <br />will be similar or equal to Roca Model No. 192 four (4) square outlet box <br />with a quad cover similar to Roco Model No. 807 with two (2) Hubell <br />Model No. 5252 duplex receptacles, <br />Receptacles required at each POS register location. Receptacles are part of <br />a 20 AMP IDG circuit with separate sub -ups at each register. See Wiring <br />Diagram this sheet and sheets E-1 and E -IA of the construction documents. <br />22. Gasoline Tank Monitor cable and future cobfes for Gas Controller/GRIND <br />Cables run form device to backroom computer with cables fastened <br />to wall. (Conduit not required). <br />23. Telephone panel (see sheet E-1 for location). Local telephone company makes all <br />telephone connections. Orders for new telephone lines are, coorinoted by the local market, <br />If local market needs assistance, nail 214-828-7942, <br />24. Electrical panels. See Sheet E-1 of the construction documents. <br />25. ATM electrical and telephone line by ATM vendor. <br />26. New 6 plex power strip supplied by NCR installer. <br />GAS CONTROLLER CABLE HOOD <br />DB25 FEMALE CONNECTOR AT <br />ISP END AND HOOD D89 MALE <br />CONNECTOR AT GAS CONTROLLER <br />EXISTING D -BOX CABLE <br />ON BACK ROOM WALL <br />EXISTING GAS CONTROLLER <br />----.-- GASOLINE - - PAM - ISDN <br />D-BOX(S) TS1000 TELEPHONE <br />_ LINE <br />SEE NOTES 12 & 3 <br />S <br />EXISTING GA50LINE GRIND CONTROL CABLE(S) -L_ ----- -P <br />CABLE IN TRENCH DISPENSERS1111 JJ lj <br />TO GASOLINE - ... CAT 5 CARL RJ45. <br />DISPENSERS F -.I �_ -.I PATCH <br />CORDS <br />NOTE: <br />1. EXISTING GAS CONTROLLER (GIBARCO MODEL PAM TS1000) <br />WILL REQUIRE ONE OF THE FOLLOWING CHANGES: <br />A. A NEW FIRMWARE CHIP TO BE PLACED <br />IN THE GAS CONTROLLER <br />AN R <br />B. A BOARD ADDITION PLACED <br />IN THE EXISTING GAS CONTROLLER <br />OR <br />C. A NEW GAS CONTROLLER WITH THE <br />NEW CHIP AND BOARD. <br />2. PETROLEUM SYSTEM CONVERSION WALK-THRU <br />FORM WILL BE PERFORMED BY THE ASC <br />3. INSTALLATION OF THE GAS CONTROLLER CHANGES AND <br />NEW GAS CONTROLLER CHIP, BOARD AND CABLE, WILL <br />BE BY ASC CERTIFIED SOUTHLAND GAS MAINTENANCE <br />CONTRACTOR. <br />POS GAS CONT ROLL <br />kREF'S <br />R DIAGRAM <br />NONE <br />a <br />0 <br />M <br />'4 PLEX LAN CABLEs'. <br />DUPLEX RECEPTACLE 12 14 4 LAN CABLES <br />TO BATTERY.'(1) PER REGISTER PLUS FUTURE - <br />1s 2 PLEX FOR CABLES 16 TELEPHONE 2 LINES <br />2 (1) FOR M.O.BATMAN CABLE #2. DEDICATED COMPUTER MODEM LINE <br />(1) FUTURE #1,. TELEPHONE VOICE LINE <br />FROM TELEPHONE BOARD <br />11I a <br />_ a <br />FIN FLR <br />TRANSFORMER PLUGS <br />- <br />26 51X FLEX STRIP '(BY NCR) <br />18 18., <br />NEW STORE RETAIL AUTOMATION <br />(MWORKSTATION ELEVATION <br />EF4 NOT TO SCALE T T2 /..� <br />20' AMP CIRCUIT <br />FOR TSP COMPUT4 PLEX <br />ER <br />20 AMP CIRCUITUR <br />FPOS <br />REGISTER 20 /. <br />RECEPtACLF /'/ IHEET PANEL <br />SP <br />�SHEET E -IA <br />TELEPHONE PANEL <br />NEW STORE RETAIL AUTOMATION <br />COMPUTER WIRING DIAGRAM <br />SCALE NONE <br />4 #3 <br />ELECTRONIC EQUIPMENT <br />nPART PLAN <br />EF4 SCALE <br />ISP BACKROOM <br />COMPUTER <br />ATM RJ45 CONNECTOR <br />SALES COUNTER <br />RJ45 CONNECTOR <br />t ONE IAN CABLE PER REGISTER, 100 FOOT LENGTH WITH NO CONNECTORS. <br />THE RJ45 CONNECTORS WILL BE INSTALLED BY THE NCR INSTALLER. <br />-D625 CONNECTORDB9 CONNECTOR <br />ONE BATMAN MONEY ORDER CABLE FOR CHEYENNE MONEY ORDER <br />MACHINE CABLE INCLUDES CHEYENNE KIT WHICH INCLUDES ONE D89 <br />CONNECTOR FOR THE MONEY ORDER MACHINE: AND ONE 082.5 CONNECTOR <br />FOR THE ISP COMPUTER END WITH A DB9 CONNECTOR, THE BATMAN <br />CABLE IS SHIPPED WITH ONE CONNECTOR IN PLACE; THE BARE END OF <br />THE CABLE IS USED TO PULL THE CABLE AND WILL REQUIRE THE <br />CONNECTOR TO BE PINNED AND INSTALLED, <br />HOOD 0825 HOOD <br />DB9 <br />FEMALE CONNECTOR MALE CONNECTOR <br />TSP END BACKROOM <br />ONE CAS CONTORLI_ER CABLE <br />DB25 GASOLINE TANK <br />FEMALE CONNECTOR MONITOR <br />BACKROOM <br />L BHLIND THIS <br />END <br />INK AS UIM INSTALLATION OF CABLE Bry MALE PINS TO BE CONNECTED <br />IN THE CABLE COVER ELECTRICAL CONTRACTOR. TO DB25 HOOD BY <br />CABLE SUPPLIED BY SOUTHIAND. ELECTRICAL CONTRACTOR <br />CABLE DETAILS <br />EF4 SCALE NONE <br />DATE: 08SEP97 <br />PROJECT NO: <br />3439.10 <br />DRAWN: MSP <br />APPROVED: CL <br />DRAWING <br />FE -2 <br />O <br />m <br />O <br />y <br />o_ <br />F- <br />J <br />N <br />U <br />Q <br />O <br />Za <br />z <br />O <br />Oc <br />w <br />O <br />J <br />W <br />w <br />J <br />$ <br />a <br />U <br />w <br />w <br />� <br />n <br />y <br />z <br />3 <br />a <br />a <br />d) <br />Z <br />4) <br />0Imo- <br />DATE: 08SEP97 <br />PROJECT NO: <br />3439.10 <br />DRAWN: MSP <br />APPROVED: CL <br />DRAWING <br />FE -2 <br />