My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1998 PLAN
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
INSTALL_1998 PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 1:04:47 PM
Creation date
11/5/2018 8:55:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1998 PLAN
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2360\PR0507204\INSTALL PLAN 1998.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 H.P STP, UPM <br />21, VENT <br />T <br />GALVANIZED SCH 40 <br />8 MPD'$ 4-10,000 :,AL. <br />12" DIA, x 2'-U" CONCRETE . RISER AT 12' ABOVE" GRADE <br />BURIED SASE (TTP,) (VACUUM VENT PER LOCAL CODE) FROM TANK TO 1 ST MPO IISE 2 1/2' PRIMARY pROOU_T LINE. <br />2" DIA. x -8'-D' GALVANIZED AND USE 1 1/2' PRIMARY PRODUCT _INF TO REST OF MPDS. <br />SCH 40 SUPPORTS <br />7'-0" ABOVE GRADE (TTP.) <br />2' U.-CLAMP—STAGE 11 <br />(TTP.) �3 FILL VAPOR RECOVERY <br />------ TANK MONITOR <br />TANK—.—SUB-PUMP <br />INTERSTICE pG <br />U -CLAMP (TYP.)� VENT RISERS ` SIPHON "BAR <br />STEEL PLATE <br />2' OTA. - 90. AT 3'. AND 5' 1 2 <br />ABOVE GRADE - 3 <br />GALVANIZED ELL `� / o! 7 p0 <br />2" FRP -G <br />GASOLINE <br />GASOLINE VENT TSCOp ` -10000" - \'ry' 2•' F.0 \ \� �„/.' <br />I/8.UNLEADED \ F <br />2 SLOPE VENTS DOWN 1/8 " RE FT. / SLAVE 0 <br />TO TANKS TTP. ALL LINES) ? P0� / UNLEADED TANK "_:1' l/ <br />MIN <br />SID\� _� <br />p`�--; FLEX CONNECTOR <br />/a"/ /T� �_ �' IT (TYP.) ti <br />2' DIA. MALE ADAPTER / ""�✓..rG,.. �`'�. ``^",."_='„_ 2 �„ ,,, v V��% <br />VENT RISER DETAIL <br />NOT TO SCALE <br />V. STEEL VENT <br />SUPPORT <br />PAINTED <br />DARK BRONZE <br />7' GALV. 90-- <br />VENT <br />0— <br />CLAMPS <br />(TYP.) <br />NOTE <br />PRIOR TO PAINTING, <br />ALL GALV METAL <br />MUST- BE PREP, <br />FREE—STANDING VENT DETAIL <br />NOT TO SCALE <br />NOTES: <br />1. VENT RISER TO EXTEND A MINIMUM OF 12' ABOVE GRADE WHEN <br />LOCATED IN REMOTE AREA <br />2. ALL STEEL PIPE & CLAMPS ABOVE GRADE PAINTEDDARK CITGO <br />BRONZE, PAINT FURNISHED BY SOUTHLAND TO THE CONTRACTOR. <br />b" THK.(4000 P.S.I.) CONCRETE <br />PAVING W/ H3'S ® 12" O.C. <br />BOTH WAYS. APPLY CONCRETE <br />SEALANT PER SPECS <br />VAPOR RECOVERY <br />LINE <br />FIBERGLASS PIPIN <br />ENVIROFLEX — <br />SECONDARY <br />PIPING <br />NOTE: <br />PEA GRAVEL <br />BEDDING <br />0 <br />SPECIFIED FILL <br />0 0 0 <br />ENVIROFLEX <br />WIDE TRENCH <br />ELECTRICAL <br />CONDUITS <br />ENVIROFLEX <br />PRODUCT LIN£ <br />PEAGRAVEL <br />SECTION THRU PIPING TRENCH <br />.NOT TO SCALE <br />NOTE: IF CONDUIT OR WATER NEEDS TO CROSS TRENCH IT <br />SHOULD DO SO PERPENDICULAR. TO PRODUCT PIPE. <br />PREMIUM1 <br />^=^ <br />10000 TANK.-.. ? X2` \IN• <br />MID GRADE <br />1 2 `\.. •. TANK Mlry. SCO <br />rA8 <br />Nkg rD 5 <br />rQWAROeFCC, SCOA <br />PIPING SCHEMATIC EIGHT ISLAND MPD'S) <br />NOTE: SEE SITE PLAN FOR PUMP AND VENT LOCATIONS <br />UPM <br />T <br />FILL STAGE II <br />VAPOR RECOVERY 6 MPD'S 2-10,000 & 1-15,000 GAL I 1/2 H.P. STP <br />TANI<r Y' FROM EACH TANK 1 1/2" PRIMARY PRODUCT LINE TO <br />INTERSTICE 1 .2 THREE MPG'S EACH. 4 <br />--- VENT RISERS <br />1 2 <br />TANK MONITOR <br />S SUB -PUMP 2 F. <br />� F <br />/AT � 1U� l '' \ F G ' <br />�so G V <br />UNLADoDED \I�, (TLEX YP.)CONNECTORS <br />10000 <br />PREMIUM....., k <br />10000 TANK. <br />�.` MID-GRADE�- <br />1 2TANK MN PO �- <br />rOwORDRFLCS LOPe <br />PIPING SCHEMATIC (SIX ISLAND MPD'S) <br />NOTE: SEE SITE PLAN FOR PUMP AND VENT LOCATIONS <br />FILL STAGE II - <br />v VAPOR RECOVERY TANK 4 "APD S 3-10,000 GAL. 1 1/2. H,P STP - <br />INTERSTICE FROM TANK TO T ST MPO USE 2 1/2 PRIMARY. PRODUCT LINE <br />-- VENT RISERSI' 2 AND USE 1 1/2 " PRIMARY PRODUCT LINE TO REST OF MPO'S <br />UPM <br />UPM <br />PEN,488 <br />TEE W/2 PLUG F- ,� 6 ..� <br />2" UNION THEN NIPPLE cc u I. <br />4" x 2'DOUBLE & 90' ELBOW O {. <br />TAP BUSHING 0.. <br />2" FIBERGLASS cc € ! is S <br />PIPE "W/3" SECONDARY CONTAINMENT PIPE U $ p <br />2" APOLLO BALL VALVE #76-,108-01 <br />OR EQUAL, MUST BE RATED FOR USE Z a 4 <br />STAVE TANK WITH ALCOHOL BLEND FUELS. Q - 0 <br />J d <br />END 2" NIPPLE <br />& UNION THEN <br />NIPPLE O m A A <br />99 DROP I o <br />TUBE I <br />BUSH NO LL w' <br />3/8 " COPPER TO = <br />FUNCTIONAL ELEMENT OF.� 2" x 2" x 2" F- O <br />SUBMERSIBLE II TEE W/2" PLUG pG <br />4" x 2"DOUBLE <br />2" NIPPLE ii TAP BUSHING y - <br />SUB PUMP END II <br />TUBE <br />I <br />II <br />U- w <br />Y <br />!n <br />W <br />NOTE: U <br />- ALL FITTINGS TO B,� J <br />CONTAINED INSIDE 42 RISER a <br />TURBINEESIIDE. m <br />SIPHON DETAIL <br />NOT TO SCALE <br />NOTE: <br />ALL SUMPS TO BE WATER TESTED <br />AS PER T.C.I. SPECIFICATIONS. <br />2 DTANK MONITOR - 4 <br />1 <br />/ •SUB -PUMP 6 <br />.NOTE: FOR VAPOR VAC INSTALLATION, <br />MIN c� / rT //z' MPU STAGE II VAPOR RECOVERY LINE <br />/�• jf°pFh N ,jl SHALL BE 2" FIBERGLASS PIPE WHEN <br />THERE ARE TWO DISPENSERS OR LESS, <br />AND 3" FIBERGLASS PIPE WHEN THERE <br />lkF.c <br />/FpP � � � � %� �. �`'� `�- ARE THREE DISPENSERS OR MORE. <br />2" <br />INV. <br />: UNLEADED <br />/a/Frpf�TANKF L—F,LETX CONNECTOR SEG Z <br />2 <br />GENERAL N <br />OTES <br />_ TANK-._=.-� Ela VAPOR UNE;' <br />00 i': PIPING TO BE TESTED UNDER PRESSURE DURING BACKFILL PROCEDURE <br />MID-GRAADEM\, F TO ASSURE NO BREACH IN SYSTEM - CHECK OFTEN DURING BACKFILL <br />1 2 TANK N AND COMPACTION. <br />r k 2. STAGE U VAPOR RECOVERY PIPING TO BE PRESSURE TESTED FOR DECAY <br />% 9 - AND BLOCKAGE PRIOR TO BACKFILLING. <br />rOw RDfFCLS3(.Ope 3 . PIPING TO BE CHECKED FOR CONTINUOUS SLOPE BACK TO THE TANKS. <br />PIPING SCHEMATIC (FOUR ISLAND MPDS) <br />NOTE: SEE SITE PLAN. FOR PUMP AND VENT LOCATIONS <br />w <br />�a <br />O <br />P <br />sa- <br />a- <br />EQUIPMENT SCHEDULE <br />ITEM <br />ca > > <br />DESCRIPTION <br />z <br />_ <br />MANUFACTURER, PART NO. <br />FURNISHED BY <br />O1 <br />FLEX CONNECTOR 2" <br />X 24" M X M <br />TITEFLEX PART NO. 110165-32-0240 <br />SOUTHLAND <br />N <br />TCI <br />,FLEX BOOT <br />TCI PART #FJO032S <br />SOUTHLAND <br />O <br />2" <br />VAPOR VENT CAP <br />(VAPOR VAC) <br />OPW PART NO. 523 LPS-2253 <br />SOUTHLAND <br />2" <br />VAPOR VENT CAP <br />(BALANCE) <br />EMCO-WHEATON PART NO. A 84-009 <br />SOUTHLAND <br />4 <br />4-1/2" ENVIROFLEX <br />SECONDARY <br />TOTAL CONTAINMENT NO. SP4500 <br />SOUTHLAND <br />5 <br />3" <br />FIBERGLASS PIPE <br />RED THREAD II OR AMERON <br />G. C. <br />0 <br />2" <br />FIBERGLASS PIPE <br />RED THREAD II OR AMERON <br />G. C. <br />7 <br />D <br />12" <br />MANHOLE ASSEMBLY <br />UNIVERSAL PART NO. 60-1280 <br />SOUTHLAND <br />-80 <br />4" <br />X 4" X 3" X 2" <br />EXTRACTOR <br />EMCO WHEATON PART NO. A 79-019 <br />SOUTHLAND <br />0 <br />GEOTECH MATERIAL <br />SEE SPEC. SECT. IIT' 2.2 <br />G.0 <br />2 DTANK MONITOR - 4 <br />1 <br />/ •SUB -PUMP 6 <br />.NOTE: FOR VAPOR VAC INSTALLATION, <br />MIN c� / rT //z' MPU STAGE II VAPOR RECOVERY LINE <br />/�• jf°pFh N ,jl SHALL BE 2" FIBERGLASS PIPE WHEN <br />THERE ARE TWO DISPENSERS OR LESS, <br />AND 3" FIBERGLASS PIPE WHEN THERE <br />lkF.c <br />/FpP � � � � %� �. �`'� `�- ARE THREE DISPENSERS OR MORE. <br />2" <br />INV. <br />: UNLEADED <br />/a/Frpf�TANKF L—F,LETX CONNECTOR SEG Z <br />2 <br />GENERAL N <br />OTES <br />_ TANK-._=.-� Ela VAPOR UNE;' <br />00 i': PIPING TO BE TESTED UNDER PRESSURE DURING BACKFILL PROCEDURE <br />MID-GRAADEM\, F TO ASSURE NO BREACH IN SYSTEM - CHECK OFTEN DURING BACKFILL <br />1 2 TANK N AND COMPACTION. <br />r k 2. STAGE U VAPOR RECOVERY PIPING TO BE PRESSURE TESTED FOR DECAY <br />% 9 - AND BLOCKAGE PRIOR TO BACKFILLING. <br />rOw RDfFCLS3(.Ope 3 . PIPING TO BE CHECKED FOR CONTINUOUS SLOPE BACK TO THE TANKS. <br />PIPING SCHEMATIC (FOUR ISLAND MPDS) <br />NOTE: SEE SITE PLAN. FOR PUMP AND VENT LOCATIONS <br />w <br />�a <br />O <br />P <br />sa- <br />a- <br />m <br />ca > > <br />z <br />a z <br />-a <br />a <br />o <br />0 <br />J <br />DATE: 08SEP97 <br />PROJECT NO: <br />3439.10 <br />DRAWN: MSP <br />APPROVED: CL <br />DRAWING <br />G-1® <br />O <br />m <br />Y <br />o <br />0 <br />J <br />F- <br />a <br />� <br />w <br />o za <br />o � <br />a <br />w <br />z a <br />U <br />a <br />h <br />z <br />Z y <br />Q <br />0 <br />V) <br />to <br />DATE: 08SEP97 <br />PROJECT NO: <br />3439.10 <br />DRAWN: MSP <br />APPROVED: CL <br />DRAWING <br />G-1® <br />
The URL can be used to link to this page
Your browser does not support the video tag.