Laserfiche WebLink
CONCRETE SLAB REINFORCEMENT TANK BURIAL <br /> CONCRETE SLAB REINFORCEMENT - - <br /> 1/4" MAX GAP #3 REBAR #4 REBARS 10" ON CENTER (2 SEPARATE MATS) \ <br /> #3 REBAR ON ,JOINT SEALER #5 REBAR PINS 30" LONG ON 18" CENTERS TYPICAL 1 1/2" CROWN <br /> 18" CENTERS 1"DEEP ON 48" CENTERS BOTH DIRECTIONS M1" MOUND CONC t 1J2" <br /> BOTH DIRECTIONS IN LOWER THIRD 5" MIN. G 8" CONC SLAB <br /> OF SLAB 7" MAX. 24" 8" CONC SLAB AROUND ALL BOXES <br /> - — <br /> 8" CONC 4%5" DESIGN NOMINAL <br /> SLAB :..,.,,,. ,. <br /> I <br /> FRP SUMP T 45 ° <br /> KEY CK - <br /> ° I IJOINT (TYP) <br /> OVERLAP MAT AND BARS I I <br /> ALUM OR PLASTIC KEYLOCK II - BY 12" MIN ALL EDGES BENCH, SLOPE, 36' <br /> FORMS W/ 2"x 5/8" LUGS — 2"TO 3" OR SHORE PER . +' DOUBLEWALL JTiNATURAL <br /> �+ <br /> CENTERED BETWEEN TANKS OSHA CODE. FIBERGLASS TANK4'-0" MINIMUM TANKS <br /> TANK 4'-5" DESIGN NOMINAL <br /> T-0" MAXIMUM MAX - <br /> I I <br /> L LINE EXCAVATION WITH I <br /> FILTER FABRIC <br /> PROD7SYMBOL0,G IF USED, FILTER FABRIC 70 BE DUPONT "TYPAR" SPUNBONDED POLYPROPYLENE STYLE 3401-4 OZ/SY OR EQUAL. <br /> ROLLS ARE AVAILABLE IN 15'-7" WIDTH AND 100, 300, OR 1000 YARD LENGTHS. INDIVIDUAL STRIPS MUST OVERLAP WELL <br /> �\ BY AT LEAST 18". FOR 3-12 THOUSAND GALLON TANKS, ESTIMATE 130 YARDS ARE REQUIRED. ALTERNATE (TYP) TYPICAL <br /> NT API PRODUCT 4' SQ #4 REBARS 10" ON MATERIALS INCLUDE PHILLIPS FIBERS CORPORATION "SUPAW 4.1 OZJSY, MONSANTO "BIDIM"C-22 4 OZ/SY, SEE TANK SLAB <br /> DE COLOR ON LID ��CENTER (BOTH WAYS) IN D9902102, XIV-9. <br /> D 2" ONTO SLAB / % UPPER THIRD OF SAB <br /> SLAB ACCESS BOX 'SHOWN WITHOUT LID j ID COLLAR Q _ <br /> TEXT SYMBOL COLORS 3 3 <br /> 8' sq. 48" D!A FRP SUMP 36 4'-5" DESIGN NOMINAL SOILPINS (TYP) <br /> MEDIUM HELVETICA TEXT & SYMBOLS i :. ., ; ;..,•... n•r• :..,•t,.•,, - - - <br /> FONTS % � - - - - <br /> crr- - - - - -- - I <br /> PREMIUM UNLEADED WHITE ON RED <br /> GASOLINE 38" DIA ACCESS BOX I _ T -� <br /> 36" } NATURAL r - 0 <br /> MID-GRADE UNLEADED r� NATURAL �v SOIL- <br /> GASOLINE `� WHITE ON BLUE SOIL C9 18" OVERLAP <br /> 8' X 8' REINFORCEMENT MATS OVER ALL TANK SUMPS DOUBLE WALL FIBERGLASS TANKS 1 <br /> 4 t 2 ALL COMMON <br /> REGULAR UNLEADED - FILTER FABRIC- \ EDGES. <br /> GASOLINE + BACK ON WHITE IF USED .d - - - - - - - - - - u <br /> DIESAUT BLACK ON YELLOW --- -- ` <br /> 1 (1 WHITE ON ORANGE - <br /> RECOVERY -� <br /> VAPORO � r � D AREAS SHOW WHERE PEAGRAVEL OR APPROVED ALTERNATE BACKFILL MATER <br /> SHADE S O IAL WILL NOT -TOP TOP EDGE HOLE <br /> (2) SIDES AND ENDCAPS OR APPROXIMATELY THE FIRST 18" TO 24"OF ABOVE THE BASE LAYER, BOTTOM EDGE HOLE <br /> OBSERVATION WELL ® BACK ON WHITE FIELD 1.5" TO INSURE PROPER BEDDING OF THIS CRITICAL AREA, PUSH A POLE OR SHOVEL HANDLE THROUGH <br /> FLOW THE BACKFILL AT A 45 DEGREE ANGLE AT 18" INTERVALS AND ROTATE TO WORK THE MATERIAL RECOMMENDED LAYOUT <br /> WASTE OIL NONE PURPLE DOWN INTO ALL VOIDS. <br /> FOR FILTER FABRIC <br /> FILTER FABRIC REQUIRED FOR LOOSFJFINE GROUND SOILS OR I <br /> /�1 WHEREVER FLUCTUATING GROUND WATER IS POSSIBLE. <br /> HEATING {I�/JI WHITE ONGREEN <br /> f a <br /> I FUEL OIL <br /> 0 X/ 9. <br /> 2.0 0 <br /> KEROSENE BROWN MPD U_ <br /> 2.0 <br /> (1) COAXIAL: SUBSTITUTE PRODUCT COLOR & SYMBOL WITHIN <br /> WHITE CIRCLE, ALTERNATE VR AND PRODUCT TEXTS MOUND CONCRETE AROUND ANY/ALL SLAB <br /> PENETRATIONS 1-1/2" TO 2 <br /> I FOR MID-GRADE, BLACK CROSS AND CIRCLE WITH WHITE CIRCLE FLOW <br /> I EXTEND MOUNDED AREA OUT FAR <br /> (2) PAINT ACCESS BOX LID BLACK. 0.0 — — ENOUGH TO INSURE DIVERTING SURFACE \ <br /> WATER WITHOUT CREATING"SPEED BUMP" <br /> SCORE LINES SCORE <br /> O (2„� LINES x,g + r t,"y,.a- <br /> (2 ) CONCRETE SLABI� ,;44 , Kky�y . CONCRETE SLAB <br /> u?F. ;tiSb; ANY SLAB ACCESS BOX <br /> REF: API 1637 PRODUCT SYMBOLS -- <br /> 0 <br /> / TANK SLAB MOUNDING <br /> GRADES LOOKING DOWN ON <br /> GRADE MOUNTED MPD <br /> i <br /> i <br /> These drawings and specifications are the confidential and ■ APPROVALS <br /> proprietary property of Shelf Oil Products US and shall not be Shell Oil Products ISS 0 0 0 CALIFORNIA U .S.T. STAN®ARDS <br /> DISTRICT MANAGER <br /> cooled, reproduced, disclosed, or used without Shell Oil p �p� { p q/'+ C TANKS <br /> Products US written authorization. They are intended as DOUBI-.EWALL FIBERGLASS <br /> contract documents for use on this specific project in AREA TECHNICAL MANAGER <br /> conjunction with its issue date and ore not suitable for use on Motiva Enterprises LLC GRAPHIC SCALE MISCELLANEOUS DETAILS <br /> ° different project or oto later date. PREV <br /> WDATE <br /> Clarification/Changes jjR ❑ TERMINAL MANAGER <br /> ICATION CHANGES ADRY 12700 Northborough Drivq SCALE: SAP/WIC # DATE: DRAWN: REQUESTED BY: <br /> Shell Oil Products US. All Ri hts Reserved 2002 / Houston TX 77067-2508 ENGINEER NONE 800062 03 MAY 2002 RABAGO HOVAN!� E0103 900 <br /> g DESCRIPTION OF REVISION BY APP <br /> I <br />