My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1995 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 1995 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 1:12:30 PM
Creation date
11/5/2018 9:02:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995 - 2008
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY 76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2420\PR0231580\COMPLIANCE INFO 1995 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 1995 - 2008
QuestysRecordDate
8/10/2018 6:20:10 PM
QuestysRecordID
3960413
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
262
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. In-Tank Gauging/SM Equipment: Z Check this box if tattle gauging is used only for inventory control. <br /> 0 Check this box if no tank gauging or SIR egoipTnent is installed. . <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection. monitoring. <br /> Com tete the following checklist.. <br /> ❑ Yes ❑ No* Has all input wiring been inspected for proper entry and termination,including testing for.ground faults? <br /> ❑ Yes ❑ No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> ❑ Yes ❑ No* Was accuracy of system product level readings tested? <br /> ❑ Yes 0 No* Was accuracy of system water level readings tested? <br /> Cd Yes ❑ No* Were all probes reinstalled properly? <br /> a Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *in the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors (LLD): 0 Check this box if LLDs are not installed. <br /> Com fete the following checklists <br /> vT—Yes 0 No* For equipment start-up or annual equipment ceoificafdon, was a leak simulated to verify LLD performance? <br /> ❑ N/A (Check A that apply) Simulated leak rate: d3 g.p.h.; ❑0.1 g.p.h; ❑0.2 g-p.h. f <br /> cr Yes © No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> Yes ❑ No* Was the testing apparatus properly calibrated? <br /> es 0 No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> ❑ N/A <br /> ❑ Yes Q * For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> O1 NIA <br /> 0 Yes L1 N * For electronic LLD&does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> [ NIA or disconnected? <br /> ❑ Yes ❑ NO For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions <br /> 2"-N/A or fails a test? <br /> 0 Yes O For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> CT NIA <br /> Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> In the Section 11„below,describe how and when these deficiencies were or will he corrected. <br /> H. Comments: <br /> Page 3 of 3 03101 <br />