'-.* I <br /> 0 <br /> t e. 7 Invoice Numbpr__ 7- S7 <br /> AES PILT-10OR <br /> HYDROSTPI*ric PRODUC-r LINE TEST WORK SHEET <br /> I TEST - 1 PRODUCT I START I END I START I END I TEST VOL. <br /> I NO. I I TIME I TIME I VOL. (ML) I VOL. (ML) I Dlla'F. (ML) <br /> L) oz' I S 1 67 , 301 <br /> Qe <br /> 7 s9 <br /> Divide the volume differential by the test time 15 minutes) , and <br /> multipl'y by 0. 0158311 cl]� will - corivert th*e vola-ohe diffdrential ' " <br /> from milliliters per Minute to gallons per, hour. <br /> The conversion constant is found by <br /> (60 min/hr) / (3790 ml/gal ) = 0. 0158311 (min/hr) (qal/ml ) <br /> 'rhe conversion constant causes the milliliters and minutes to <br /> cancel QlAt. <br /> Ex. If the level dropped 3ml in 15 atinutes then : <br /> 3/15 ml. /min. X 0. 0158311 (min/hr) (gal/ml ) := 0. 003 gal/hr. <br /> RESUL-r5 OF THIS WORK SHEET TO BE COMPILED ON RESULTS SHEET. <br />