G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 1995 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 1:12:30 PM
Creation date
11/5/2018 9:02:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995 - 2008
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY 76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2420\PR0231580\COMPLIANCE INFO 1995 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 1995 - 2008
QuestysRecordDate
8/10/2018 6:20:10 PM
QuestysRecordID
3960413
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
262
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' SAN JOAQUIN COUNTY <br /> t ONVIRONMENTAL HEALTH DEPARTMENT 40 <br /> 304 East Weber Avenue, 3rd Floor, Stockton,CA 95202= 708 <br /> tr Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sij4ov.org/ch <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> 6apa'r, lel we VAL&(Lo STN(iRlJ S 3-�-Oto <br /> Facility address: UST# C , <br /> �.L}-10 w. &M r` k-ANE: R o Product <br /> Facility Contact: Title: Phone: <br /> i4p„J M(N4" A(ztN(:�Q' - S 32-It <br /> Monirt�orrr�n}¢-fP,anel: , ^,,' `yP'ping system: O•erfrll prevention: <br /> W�•"�+ G"�`-' /UPressurized ❑Suction ❑Gravity Mechanical ❑Audible/visual <br /> Inspection type: �� Violations: <br /> ❑Routine L2 Monitoring Certification El Installation Other: ❑MI-RDetect ❑M2-RPrev ❑M-3 Both <br /> # Code Section <br /> VIOLATIONS) HSC=Califomia Health&Safety Code;CCR=Califomia Code of Regulations V R V=Violation;RV=Re eat Violation V <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 6 &(c) Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632(c)(2)(D) Monitoring&response plan is current and filed with the local agency <br /> _ <br /> 6 CCR 2712(i) Monitoring&response p Tan is onsite <br /> 7 CCR 2712(b) Maintenance&monitoring records (Ml) <br /> 8 CCR 2643 (d) Daily monitoring of suction piping(pre-January, 1, 1984 <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present Ml <br /> 11 CCR 2630(d) UST system monitoring equipment is properly located to detect a leak Ml <br /> 12 HSC 25291 (b) UST system monitoring equipment p isoperational M2 <br /> 13 CCR 2636(n(l) Continuous monitoring system for underground piping&UDC is present Ml <br /> 14 CCR 2631 (a) Priminry containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> . 16 CCR 2636(c)(1) All releases in secondpipingpflow to a collection sum <br /> 17 HSC 25291 (t) Line leak detectors are installed Ml <br /> 18 CCR 2635(b)(1) Spill container (M2) <br /> 19 CCR 2635(b)(2) Overfill prevention system M2 <br /> 120 CCR 2636(a) Conventional suction piping shall have continuous monitoring&20 containment <br /> 21 HSC 25291 (e) Water in 20 containment analyzed&properly disposed of <br /> 22 CCR 2650 Recordingtreporting of unauthorized releases Ml <br /> 23 CCR 2715 Desi nated Operator: a)Statement from UST owner; (c-e)Monthly inspection;(t)Employee training <br /> 24 CCR 2638 a) Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (M 1) <br /> 26 HSC 25284.2 .Annuals ill containment testing <br /> 27 CCR 2636(n(4) Annual line tightness test Ml <br /> 28 CCR 2661 (f) Repair for tank/piping has had tightness test M2 <br /> 29 CCR 2643(e) Biennial tightness test ofgravity piping re-Janus 1, 1984 <br /> 30 CCR 2643 d Triennial line test for conventional suction ppipingg(pre-January 1, 1984 (MI) <br /> 31 HSC 25292.5 Double walls stem located within 1000'ofpublic well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a) Permit to alter monitoring system <br /> 34 HSC 25298(b) Permit to temporarily close UST system <br /> 35 HSC 25298(c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disablin leak detection devices <br /> 37 HSC 25298 a) Ille al abandonment of UST s stem <br /> 38 Other: C,o+++PUPAjCk- <br /> EHD INSPECTOR: PHONE: UIC <br /> LLQ. qb g-_-51% 0b Septic system: <br /> _N(Al. l ❑Serves>_20 people/day <br /> RECEIVED BY: TITLE: ❑Receives other than sanitary waste <br /> t Other disposal methods: <br /> ❑Dry wells/French Drains <br /> FHD 23-02-002 <br />