My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1995 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 1995 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 1:12:30 PM
Creation date
11/5/2018 9:02:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995 - 2008
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY 76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2420\PR0231580\COMPLIANCE INFO 1995 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 1995 - 2008
QuestysRecordDate
8/10/2018 6:20:10 PM
QuestysRecordID
3960413
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
262
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Coder Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: Roshan Valero Service Station No.: <br /> Site Address: 2420 Grant Line Rd City: Tracy Zip: <br /> Facility Contact Person: Roshan Minhas Contact Phone No.: 209-832-8273 <br /> Make/Model of Monitoring System: ��/,� ' -.� -1s2 r Date of Testing/Service: <br /> B. Inventory of Equipment Tested/Certified <br /> Check the apprTriate boxes to indicatespecific a ui ment ins ected/serviced: <br /> Tank ID: Tank ID: <br /> On-Tank Probe: Model: Mit-Tank Gauging Pro e: Model: e 0 <br /> QAnnular Space or Vault Sensor: Model ,4y31 a- yA62 ❑Annular Space or Vault Sensor Model: <br /> Mping Sump/Trench Sensor(s): Model: W=,t- ;.2c6 ' ENNping Sump/Trench Sensor(s): Model: Z 43c'0 d <br /> ❑Fill Sump Sensor(s): Model: ❑Fill Sump Sensor(s): Model: <br /> EII�Acchanical Line Leak Detector. Model: n QMechanical Line Leak Detector. Model 447 2,V67v <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank OverfiliN igh-level Sensor: Model: ❑Tank Overfill/High-level Sensor: Model: <br /> ❑Other, Smalf suiz and model in Section E on Pae 2 ❑Other, S ui . and model in Section E on Pae 2 <br /> Tank ID: Tank ID: <br /> TA-Tank Gauging Probe: Model: /' 7. y ❑In-Tank Gauging Probe: Model: <br /> @'Annular Space or Vault Sensor: Model: 7.9v3jo_ ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s): Model: c?3 ❑Piping Sump/Trench Sensor(s): Model: <br /> ❑Fill Sump Sensor(s): Model: ❑Fill Sump Sensor(s): Model: <br /> (Mechanical Line Leak Detector. Model: Z []Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank Overfill/Mgh-level Sensor: Model: <br /> ❑Other, S fui . and model in Section E on Pae 2 ❑Other, Specffy Speceguip. type and model in Section E on Pa e 2 <br /> Dispenser ID: —2 Dispenser ID: <br /> ❑Dispenser Containment Sensors: Model: ❑Dispenser Containment Sensor(s): Model: <br /> lWShear Valve(s). VKhear Valve(s). <br /> UWi nscr Containment Float(s)and Chains) Mis nser Containment Float(s)and Cham(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensors: Model: ❑Dispenser Containment Sensor(s): Model: <br /> f'Sbear Valve(s). ❑ Shear Valve(s). <br /> EWispenser Containment Float(s)and Chain(s) ODispenser Containment Float s)and Cham(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensors: Model: ❑Dispenser Containment Sensor(s): Model: <br /> &9hear Valve(s). ❑ Shear Valve(s). <br /> UWispenser Containment Float(s)and Cham(s) 013ispenser Containment Float(s)and Chains) <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at this facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipmeyt capable of generating such <br /> reports,I have also attached a copy of the report; (check all that apply): fB System Sete army to report <br /> Technician Name(Print): Keith Huston Signature: <br /> Certification No.: e�,�r 4 G g^x-2. 7 License No.: <br /> Testing Company Name: Champion Precision Testing, Inc Phone No.: (916)927-1557 <br /> Pacer 1 of.3 nasal <br />