Laserfiche WebLink
ENVIROENTAL HEALTADEPARTMENT <br /> pU N SAN JOAQUIN COUNTY <br /> OP O <br /> Donna K. Heran, R.E.H.S. Unit Supervisors <br /> Director 304 East Weber Avenue,Third Floor Carl Borgman,R.E.H.S. <br /> y. At Olsen, R.E.H.S. Stockton,California 95202-2708 Mike Huggins, R.E.H.S., R.D.1. <br /> CqC F p0.N�P Program Manager Telephone: (209)468-3420 Douglas W.Wilson,R.E.H.S. <br /> Laurie A. Cotuna, R.E.H.S. Margaret Lagorio,R.E.H.S. <br /> Program Manager Fax: (209)464-0138 Robert McClellon, R.E.H.S. <br /> August 3, 2005 Website:www.sjgov.org/ehd/ Jeff Canuesco, R.E.H.S. <br /> ROSHAN MINHAS <br /> VALERO <br /> 2420 W GRANT LINE RD <br /> TRACY CA 95376 <br /> RE: VALERO,2420 W. Grant Line Rd, Tracy, CA 95376 <br /> The San Joaquin County Environmental Health Department(SJCEHD)has received the permit to <br /> replace existing spill buckets and install overfill prevention device at the above referenced location. <br /> The permit has been approved with the following conditions: <br /> 1. Contact the local fire department, and the San Joaquin Valley Air Pollution Control District <br /> for applicable permits and requirements. <br /> 2. Any changes in information or scope of work must be submitted to SJCEHD prior to <br /> commencing work. <br /> 3. At least one person who holds the International Code Council"UST Installer/Retrofitter" <br /> certification must be onsite AT ALL TIMES when work is performed. <br /> 4. A "Certificate of Compliance for Underground Storage Tank Installation Form C" shall be <br /> submitted by the owner or the owners'agent [pursuant to California Code of Regulation <br /> (CCR)2635(d)]before this upgrade will be considered complete by SJCEHD. <br /> 5. Contact Willy Ng at(209)468-3448 to arrange the following inspection appointments; a 48- <br /> hour notice for inspection appointments is required. <br /> a. Corrosion protection: prior to backfilling around the spill buckets, corrosion protection <br /> of the risers must be verified. <br /> b. Overfill prevention: overfill prevention system in compliance with CCR 2635 (b)(2) <br /> must be verified. <br /> c. Spill Bucket: after concrete is poured, verify minimum 5-gallon capacity and conduct a <br /> 30-minute lake test in compliance with CCR 2635(b)(1). Proper drainage must also be <br /> verified. <br /> d. Third party tank integrity tests must be performed once concrete is poured,prior to the <br /> contractor signing off of the jobsite. The test results must be submitted to SJCEHD <br /> within 7 days of completing this project. <br /> 6. Permit expires 90 days from the approval date. Note: if an extension to the expiration date is <br /> required, this office must receive a written request prior to the expiration date. <br /> Thapk you, <br /> Willy Ng, S . <br /> San Joaquin County <br /> Environmental Health Department <br />