My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MINIMUM VERIFICATION LABORATORY ANALYSIS <br /> OXYGEN <br /> TANK TANK TPH-G TPH-D BTX&E CL HC TOTAL MTBE ATES MVrAL PCB <br /> # CONTENTS 8015 8015 8020 8010 LEAD 8020 (MTBE. ICRP/ 8270 <br /> 8260 8260 8260 8240 7420 8260 TBA DIPE, AES or 8080 <br /> 8260 7421 ETRE, AA <br /> TAME) <br /> 8260 <br /> LEADED GASNX <br /> rx X X <br /> UNL GAS X <br /> DIESELX <br /> KEROSENE X <br /> UNK FUEL X X X X X <br /> PROD.OIL X X X <br /> CHLOR. X <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTS X X <br /> WASTE\ <br /> USED OIL X X X X X X X <br /> All analysis methods are the designated EPA methods described in EPA SW 846,Third Edition. Those methods not found in SW 846 are <br /> specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix D (B), Table 3-5 on page A20 for minimurn detection <br /> limits for motor vehicle fuel (gasoline and diesel). Refer to "Tri-Regional Board Staff Recommendations for Initial Evaluation and <br /> Investigation of USTs" for the waste and motor oil minimum detection limits. Detection Limits that remain below the MCL,STLC or <br /> Allowable Limit of the contaminant in question will be accepted,however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon,Gasoline,GC/FID(5030)8015 mod or GC/MS 8260 <br /> TPH-D Total Petroleum Hydrocarbon,Diesel,GC/FID(3550),8015 mod or GC/MS 8260 <br /> BTX&EBenzene,Toluene,Xylene&Ethyl Benzene,GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC/HSD 8010,GC/MS 8240 or 8260 <br /> TOTAL LEAD Total lead,AA 7420, AA 7421 or ICP-AES 6010 <br /> OXYGENATES MTBE,ETBE,TAME,DIPE,&TBA GC/MS 8260(For MTBE screen only you may use 8020) <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000. Metals: <br /> Cadmium,Chromium III and VI,Lead,Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls,GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-free solvents are to be used. Fused capillary columns are preferred to packed columns;a <br /> packed column may be used as a"first cut"with"dirty"samples or once the hydrocarbons have been characterized and proper QA/QC is followed. For <br /> drinking water sources,EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the detection <br /> limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination may require further analysis.PHS-EHD <br /> recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 05/09/00) <br />