My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LG 1'13 Vendor/Template Pagel of 2 <br /> me "a <br /> Issue date:August 28, 1998 <br /> Revision Date:April 27,2004 <br /> Veeder-Root <br /> TLS-300, 300i, TLS-350 Series, Red Jacket ProMax and ProPlus with <br /> Discriminating Dispenser Pan Sensor 794380-322., <br /> Discriminating Containment Sump Sensor 794380-352 <br /> LIQUID-PHASE INTERSTITIAL DETECTOR <br /> Detector: <br /> Output type: qualitative <br /> Sampling frequency: continuous <br /> Operating principle: product permeable, reed switch/float <br /> Test Results: <br /> *California requires annual certification of all leak detection equipment. The certification of discriminating <br /> sensors should include functional testing of both water and product detection capabilities. <br /> Model 794380-322 and 794380-352: Currently the SWRCB UST Program staff discourages the use of polymer <br /> strip discriminating sensors at new installations in California. This is due to concerns about the impact that <br /> repeated/prolonged exposure to hydrocarbons may have on the sensor's ability to alarm and recover from <br /> alarm reliably. Since current evaluation protocols do not address this issue, no new polymer strip sensors <br /> should be installed until new evaluation protocols are in place. <br /> pol mmer_strip float switch <br /> unleaded gasoline diesel water <br /> Discriminating Dispenser Pan <br /> Sensor 794380-322 high* low* <br /> Response time (sec) —10 min 2-12 hrs <1 <1 <br /> Recovery time (sec) N/A** N/A <1 <1 <br /> Lower detection limit - height (in) N/D** N/D 7.66 1.37 <br /> Lower detection limit - thickness (in) 0.005 0.005 N/A N/A <br /> Discriminating Containment Sump <br /> Sensor 794380-352 <br /> Response time (sec) —10 min 2-12 hrs <1 <1 <br /> Recovery time (sec) N/A N/A <1 <1 <br /> Lower detection limit - height (in) N/D N/D 12.28 1.35 <br /> Lower detection limit - thickness (in) 0.005 0.005 N/A N/A <br /> *The "high" and "low" refer to high and low level alarm points of float switch sensors. <br /> ** See glossary. <br /> Specificity Results (in addition to above): <br /> Activated: synthetic gasoline, jet-A fuel, n-hexane, toluene, xylene(s) <br /> http://www.swrcb.ca.gov/past/leak_prevention/lgl13Nendor Files/veeder root_o.html 9/9/2004 <br />
The URL can be used to link to this page
Your browser does not support the video tag.