My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAK 2 0 2006 <br /> 2006 1MAR 23 Pt; 2: 58 <br /> r <br /> FASTECH, INC. <br /> Construction, Compliance Testing, Engineering, &Station Maintenance <br /> March 17,2006 <br /> Mr. Doug Wilson 989 3 YEAR COMPLIANCE TEST <br /> San Joaquin County Environmental Health Division <br /> 304 East Weber <br /> Stockton,CA 95202 <br /> SUBJECT: SB 989 COMPLIANCE TESTING AT COSTCO STATION 3250 W. GRANT LINE & HWY. 205, <br /> TRACY,CA 95304. SITE NUMBER 658. <br /> Dear Mr. Wilson: <br /> Below please find the secondary containment testing results for the above-referenced site. These results are being sent to <br /> you per the requirement of SB 989. In accordance with SB 989, Costco last tested the above-referenced site's secondary <br /> containment components on 3/26/03. Costco is now retesting the secondary containment components within 36 months <br /> as required by SB 989. San Joaquin County Environmental Health Division (SJCEHD) was notified for the current <br /> testing on 1/18/06. If any of the secondary containment components failed or were not tested at this facility, repairs will <br /> be made within 30 to 120 days. If, for some reason, the repairs will take more than 120 days, your Agency will be <br /> immediately notified. A summary of the components tested is listed in the table below. <br /> CONTRACTOR: FASTECH.;License No: 794519 <br /> TECHNICIAN: Cesar Plascencia <br /> • SB 989 Testing Results <br /> Components Tested Component Date Tested Type of Test Pass/ <br /> Manufacturer Performed Fail <br /> Regular Annular—T 1 Owens Corning NA—Wet Annular NA NA <br /> Regular Annular—T2 Owens Coming NA—Wet Annular NA NA <br /> Premium Annular Owens Coming NA—Wet Annular NA NA <br /> Regular Secondary Product Line Environ 3/14/06 Pressure Pass <br /> Regular Secondary Product Line—Siphon AO Smith 3/14/06 Pressure Pass <br /> Premium Secondary Product Line Environ 3/14/06 Pressure Pass <br /> Manifolded Gasoline Secondary Vent & Vapor AO Smith 3/14/06 Pressure Fail <br /> Line <br /> Regular Turbine Sum —Tl Total Containment 3/14/06 Hydrostatic Pass <br /> Regular Turbine Sum —T2 Total Containment 3/14/06 Hydrostatic Pass <br /> Premium Turbine Sump Total Containment 3/14/06 Hydrostatic Pass <br /> Regular Fill Sum —TI Total Containment 3/14/06 Hydrostatic Pass <br /> Regular Fill Sum —T2 Total Containment 3/14/06 Hy drostatic Pass <br /> 7050 Village Drive, Suite D Buena Park,California 90621 Phone(714)523-0194 Fax(714)5234235 <br />
The URL can be used to link to this page
Your browser does not support the video tag.