Laserfiche WebLink
MAK 2 0 2006 <br /> 2006 1MAR 23 Pt; 2: 58 <br /> r <br /> FASTECH, INC. <br /> Construction, Compliance Testing, Engineering, &Station Maintenance <br /> March 17,2006 <br /> Mr. Doug Wilson 989 3 YEAR COMPLIANCE TEST <br /> San Joaquin County Environmental Health Division <br /> 304 East Weber <br /> Stockton,CA 95202 <br /> SUBJECT: SB 989 COMPLIANCE TESTING AT COSTCO STATION 3250 W. GRANT LINE & HWY. 205, <br /> TRACY,CA 95304. SITE NUMBER 658. <br /> Dear Mr. Wilson: <br /> Below please find the secondary containment testing results for the above-referenced site. These results are being sent to <br /> you per the requirement of SB 989. In accordance with SB 989, Costco last tested the above-referenced site's secondary <br /> containment components on 3/26/03. Costco is now retesting the secondary containment components within 36 months <br /> as required by SB 989. San Joaquin County Environmental Health Division (SJCEHD) was notified for the current <br /> testing on 1/18/06. If any of the secondary containment components failed or were not tested at this facility, repairs will <br /> be made within 30 to 120 days. If, for some reason, the repairs will take more than 120 days, your Agency will be <br /> immediately notified. A summary of the components tested is listed in the table below. <br /> CONTRACTOR: FASTECH.;License No: 794519 <br /> TECHNICIAN: Cesar Plascencia <br /> • SB 989 Testing Results <br /> Components Tested Component Date Tested Type of Test Pass/ <br /> Manufacturer Performed Fail <br /> Regular Annular—T 1 Owens Corning NA—Wet Annular NA NA <br /> Regular Annular—T2 Owens Coming NA—Wet Annular NA NA <br /> Premium Annular Owens Coming NA—Wet Annular NA NA <br /> Regular Secondary Product Line Environ 3/14/06 Pressure Pass <br /> Regular Secondary Product Line—Siphon AO Smith 3/14/06 Pressure Pass <br /> Premium Secondary Product Line Environ 3/14/06 Pressure Pass <br /> Manifolded Gasoline Secondary Vent & Vapor AO Smith 3/14/06 Pressure Fail <br /> Line <br /> Regular Turbine Sum —Tl Total Containment 3/14/06 Hydrostatic Pass <br /> Regular Turbine Sum —T2 Total Containment 3/14/06 Hydrostatic Pass <br /> Premium Turbine Sump Total Containment 3/14/06 Hydrostatic Pass <br /> Regular Fill Sum —TI Total Containment 3/14/06 Hydrostatic Pass <br /> Regular Fill Sum —T2 Total Containment 3/14/06 Hy drostatic Pass <br /> 7050 Village Drive, Suite D Buena Park,California 90621 Phone(714)523-0194 Fax(714)5234235 <br />