..S,WRCI3,January 2002 1.01 Page of /If <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: 0 Sump Manufacturer X Industry Standard 0 Professional Engineer <br /> 0 Other(Spec) <br /> Test Method Used: 0 Pressure 0 Vacuum X Hydrostatic <br /> 0 Other(Spec) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: <br /> Sump# f Sump# Sump# Sump# <br /> Sump Diameter: <br /> Sump Depth: y 4' <br /> Sump Material&Manufacturer: Q&fit c, .s Tc t <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: e, <br /> 4 <br /> Height from Tank Top to Lowest c <br /> Electrical Penetration <br /> Condition of sump prior to testing. z'r,' <br /> ' Above highest Above highest Above highest <br /> Portion of Sump TestedAbove highest <br /> penetration enetranon penetration Penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both 0 Yes D No X NA 0 Yes 0 No X NA 0 Yes 0 No X NA 0 Yes 0 No X NA <br /> product and water)?" <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe X Yes 0 No ENA X Yes 0 No DNA X Yes 0 No DNA X Yes 0 No [INA <br /> shutdown?" — — — <br /> Was fail-safe verified to be D Yes X No [INA D Yes X No DNA Dyes X No DNA Dyes _XN0 DNA <br /> operational?" — <br /> Wait time between applying <br /> pressure/vacuum/water and starting 30 minutes 30 minutes 30 minutes 30 minutes <br /> test: <br /> Test Start Time: <br /> Initial Reading(Rr): / S Ski <br /> Test End Time: <br /> Final Reading(RF): /53- $,j /' s oc-s/ <br /> Test Duration: /57 - t <br /> Change in Reading(RF�Ro: tjo U G G!p <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: Pass D Fail ass 0 Fail 0 Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing? X Yes 0 No CNA X Yes 0 No DNA X_Yes 0 No DNA X Yes 0 No DNA. <br /> Was sensor properly replaced and X Yes 0 No DNA X Yes 0 No DNA X Yes 0 No DNA X Yes 0 No DNA <br /> verified functional after testing? <br /> — — <br /> Comments—(include information on repairs made prior to testing and recommended follow-up forfailed tests) <br /> SB 989 3-Year Compliance Testing _ <br /> WO#060310-045 <br /> COSTCO#200737 — <br /> 3250 W Grant Line I Hwy 205 — <br /> Tracy,CA 95304 <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />