EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2023 1:00:14 PM
Creation date
11/5/2018 9:19:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2002
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\INSTALL 2002.PDF
QuestysFileName
INSTALL 2002
QuestysRecordDate
7/5/2017 9:39:11 PM
QuestysRecordID
3482255
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYP. T 4 3 34 41 BETWEEN <br /> TO 6" CLEARANCE <br /> 2 H.P. F.E. PETRO TURBINE 4-1 <br /> sr-s-i/z" I z•-°" I SEE FOR PLAN VIEW AND ACCESSORIES BL-I'WEEN CAP AND � <br /> --- <br /> _ - CONTRACTOR TO INSTALL BRASS 30 <br /> Typ, TYP. ER. SEE NOTE 5 <br /> I.D. PLATE w/ ANCHOR BOB. ( <br /> 6" MIN., 12" MAX. FROM 2" CROWN ENGRAVED w/ SIZE OF TANK IN 2" CROWN J D <br /> 7._8,. °'-8•• TURBINE MANHOLE LID SEE NOTE #7 GALLONS & GRADE OF PRODUCT 9 10 15 16 7 SEE NOTE #7 <br /> -- -- -- TO MECH. LEAK DETECTOR 35 „ <br /> ITJ <br /> �P. i/z^ 24 TYP. 24 ' TYP. w 0 <br /> TYP. MIN. MIN. W z <br /> A .� ° ai M13 <br /> 3" MIN. CLEA TO LEVEL GAU E - 0 Ir W U LL <br /> PREMIUM UNL. 92 OCTANE RTYP.) /-3/4" J-BOX 4 BLACK IRON PIPE <br /> ELECTRICAL RISER ALL RISERS TO ��" MIN CLEAR Z � Z �"' Z <br /> 20,000 GALLON 30" ;.ANWAY 3/4" CONDUIT SEAL-OFF (TYP.) BE WRAPPED �P') w o Z J 0 J <br /> 8 16" TANK #3 z^ iz" TURBINE POWER - (SEE NOTE #9) w/10 MIL TAPE. 3/4" J-BOX. J - 1- Q Q <br /> O ` ELECTRICAL 4 Z Ig2 (SEE NOTES #2 & #3) I 18 3/4" CONDUIT SEAL-OFF (TYP.} 3 4„ (� Q <br /> (SEE NOTE #9) SEE NOTE #9) 18 / F- <br /> lo 1 I E F K _ WFT 80 OZ. CONDUIT Q Q <br /> 3/4 ' CONDUIT 18 54 � ('3 <br /> - - - I ti o (SEE NOTE #9) 56 SNUFFER BRACKET 4 V <br /> CROSS CONNECTION i^ MOUNTED (TYP.) (SEE NOTE #4) $ O <br /> BETWEEN UNLEADED 33CONNECTORX 18 3/4" CONDUIT NWFT 80 OZ. Y N (n <br /> I O (SEE NOTE - 56 SNUFFER BRACKET N I (� Q <br /> TANKS. BALL VALVE --J 36 W/ 4" RISER MOUNTED (TYP) CO) <br /> NORMALLY CLOSED -- - AND CAP (I_N O1 7 N 0 <br /> 2 ----- 3 INV ) 4 <br /> ' - BACKGROU D 14 " m <br /> LL <br /> / N <br /> o *NOTE: PIPING IN THIS VIEW --- - 19 SUMP MONITORING m a <br /> a SHOWN FOR CLARITY. LIQUID SENSOR <br /> " SIPHON PIPING NOT SHOWN (SEE ODE #4)MOU12 2" BALL FLOAT N <br /> (8) 2" CLOSE NIPPLES FLUSH TO BOTTOM <br /> (1) 2" x 12" M-NPT x M-NPT SWIVEL FLEX 33 LEVEL GAUGE TURBINE EXTENDS TO 4" DROP TUBE 11 <br /> UNLEADED 87 OCTANE CONNECTOR 2" BLACK STEEL SIPHON <br /> WITHIN 6" OF BOTTOM <br /> 20,000 GALLON MANWAY (2) 2" NP T-100-708 BALL VALVE 54 STINGER. EXTEND TO WITHIN SUMP MONITORING <br /> jf3O- (3) 2" NPT ELBOW 6" OF BOTTOM OF TANK. OF TANK 19 LIQUID SENSOR <br /> 8 TANK #2 (1) 2" NPT TEE (SEE NOTE #4) <br /> MOUNTED <br /> O ( ) O Turbine Sump Section FLUSH TO BOTTOM <br /> ' A2 ENVIRON SMA-2020 2" SWIVEL MALE PIPE 44ADAPTER (Tanks #1 and #2 Only) D Fill Sump Section (All Tanks) <br /> T- (2) ENVIRON SPC-0200 2" SWIVEL PIPE COUPLING 4 NE T - -- - (2) ENVIRON STB-0200 2" STANDARD TEST BOOT(2) ENVIRON GTT-3836 GEOFLEX TEST TUBE 51 T-Z NOT TO SCALE T-Z NOT TO SCALE <br /> B <br /> SEE T-4 FOR PLAN VIEW 37 34 41 AND.ACCESSPETRO <br /> E T O TURBINE <br /> 6" MIN., 12" MAX. FROM 35 24" TYP 2" CROWN F.R.P. RISER TOP <br /> TURBINE MANHOLE LID SEE NOTE #7 *NOTE: <br /> TO MECH. LEAK DETECTOR MIN. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR <br /> REINFORCED CONCRETE SLAB ABOVE ° PROPER INSTALLATION & PREPARATION PER <br /> SEE CIVIL DRAWING FOR SPECIFICATIONS - MANUFACTURERS INSTRUCTIONS AND SHALL <br /> REINSTALL SUMPS IF HYDROSTATIC TESTING <br /> SHOWS LEAKING IN THIS AREA OF THE SUMP. J <br /> DIMF MIN. CLEAR F.R.P. RISER TOP (TURBINE SIDE ONLY) Q L11 O <br /> TO LEVEL GAUGE — 3(TYP.) FIELD SEALED � OD <br /> 0 <br /> UNLEADED 87 OCTANE 3/4" J-BOX JOINT. ADHESIVE <br /> ELECTRICAL SUPPLIED W LLJ � � <br /> 30" MANWAY SEAL-OFF TYP.) 3/4" CONDUIT & J-BOX ( -� <br /> (TYP. 3) 6^ <br /> 20,000 GALLON <br /> A1LON z" 1z^ ( -- KIT) SEE NOTE SLIP ON 0 Q <br /> (SEE NOTE #9) 4 _ (FUTURE TURBINE POWER) ABOVE FRP REDUCER n Q <br /> # 3 4" CONDUIT 18 24 3S 1 /2 <br /> A / g ACCESS OPENING � <br /> (SEE NOTE #9) I _ <br /> -- 54 (SEE #2 & #3) <br /> .,, - - ---------- <br /> f TE INE T K _ 1 2"X12° FLEXQ r - ---- -- - ® J <br /> SLIP ON 0) O <br /> NWFT 80 OZ. RISER Q <br /> SNUFFER BR CKET56 SEE NOTE #9) 48" I.D. W <br /> / \ O I 1� 3/4 ' CONDUIT CONTRACTOR TO INSTALL : � U <br /> 8 MOUNTED ITYP.) I I ( U) O <br /> W/ 4" RISER 36 s:€'= ( FIBER MESH WRAP AT o <br /> 18" MANHOLE C S AND CAP EXTERIOR JOINTS <br /> TO ANNULAR ON R 1 3 > <br /> (TYP.. 3) COLLAR <br /> BONDED TANK <br /> FACTORY TO TANK WALL <br /> *NOTE: PIPING IN THIS VIEW 30" MANWAY LAY-UP <br /> OUTLINE OF CONCRETE CROWN o SHOWN FOR CLARITY. SEE 19 SUMP MONITORING o <br /> 18" MIN. ivJ LIST BELOW. LIQUID SENSOR <br /> (SEE NOTE #4) U_ <br /> (7) 2" CLOSE NIPPLES _ MOUNTED <br /> 7 35 (1) 2" x 12" M-NPT x M-NPT SWIVEL FLEX 33 FLUSH TO BOTTOM -- <br /> 37"x12" DEEP WATER-TIGHT MANWAY WITH 37"x10 3/4" DEEP WATER-TIGHT CONNECTOR TURBINE EXTENDS TO <br /> (2) 5 GALLON SPILL CONTAINERS WITH Tank Plan MANHOLE/LID ASSEMBLY (1) JOMAR T-100-708 BALL VALVE 54 WITHIN 6" OF BOTTOM *NOTE: <br /> INTEGRAL DRAIN ASSEMBLIES AND 1 FOR TURBINE SUMP ENTRY (TYP. 3). (4) 2" NPT ELBOW OF TANK THE RISER SHOWN IN THIS VIEW IS WATERTIGHT AND IS USED IN ALL LOCATIONS <br /> REMOVABLE LIDS FOR EASY ACCESS. (TYP. 3) (t) 2' NPT TEE MODEL WTE48-6 <br /> T-2 NOT TO SCALE (2) ENVIRON SMA-2020 Z" SWIVEL MALE PIPE 44 Turbine Sump Section Turbine and Fill 3 4 <br /> ADAPTER <br /> (2) ENVIRON SPC-0200 2" SWIVEL PIPE COUPLING 42 B (Tank #3 Only) E Sump Riser Standard <br /> (2) ENVIRON STB-0200 2" STANDARD TEST BOOT 48 r <br /> (2) ENVIRON GTT-3836 GEOFLEX TEST TUBE 51 T-Z NOT TO SCALE T-Z NOT TO SCALE <br /> (FUTURE) Sheet Notes <br /> TANK ' TANK TANKS <br /> #3 #3 #1 - 1 . - TANK(S): SHALL BE UNDERWRITERS LABORATORY APPROVED AS CALLED FOR ON THE z <br /> - o <br /> SITE <br /> ING OR AS <br /> ATED ON <br /> HE <br /> ENTAL CONDITIONS <br /> D C B A SHALL BE IDIOUBLEWWALL TANKSOFFIBERGLASS S TREINFORCEDMPLASTIC (FRP) AS AND s <br /> 5 GALLON CONTAINMENT FILL END T-2 T-Z T-Z TURBINE END MANUFACTURED BY FLUID CONTAINMENT INC. INSTALLATION OF TANKS AND PIPING <br /> --------- --------------- SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE INSTALLATION SPECIFICATION N & N o <br /> 8 I I 2" HIGH CROWN TYP. REINFORCED CONCRETE AS PROVIDED BY COSTCO WHOLESALE, AND MANUFACTURERS INSTRUCTIONS. <br /> i6^ I SLAB SEE CIVIL DRAWINGS -- <br /> O 4" DIA. FRP OR SCH. 80 AROUND ALL OPENINGS II <br /> 55 TYP. TYP. 2. - PIPING PENETRATIONS: ALL PENETRATIONS OF THE TANK SUMPS SHALL BE SEALED WITH BULKHEAD m v <br /> PVC RISER SEE NOTE 7 FITTINGS AND NOT EXCEED 15° ANGLE IN ANY DIRECTION TO ENSURE THE PROPER INSTALLATION OF o o 0 < S <br /> ALL BULKHEAD AND COMPRESSION FITTINGS AND RESULTANT WATER- TIGHTNESS. ALL PIPING, CONDUIT <br /> 4'-0" MIN. TO <br /> AND GROUNDS THAT PENETRATE THE . SUMP SIDE WALLS MUST BE SEALED IN SUMPS. SUMPS <br /> SINGLE FLOAT 0 � i TLS 35 � �4L/ J" SHALL BE HYDROSTATIC ALLY TESTED WITH STANDING WATER FOR A PERIOD OF 24 HOURS TO <br /> HYDROSTATIC SENSOR <br /> 7'-0" MAX. COVER I q TO MONITORING INSURE THAT THE SUMPS ARE WATERTIGHT. <br /> Efl <br /> SYSTEM (TYP. 3) 3. - PIPING TESTING: TESTING OF THE SECONDARY CONTAINMENT PIPING IS REQUIRED. THE SEALING = <br /> BRINE R-28 HYDROSTATIC j o BOOT IN THE SUMP IS TO BE INSTALLED WITH THE VALVE TURNED DOWN. AFTER z <br /> RESERVOIR 0 z vW <br /> TESTING THE VALVE IS TO BE OPENED TO ALLOW DRAINAGE OF THE SECONDARY ag <br /> T2�1 MAX. (TYP.) n .r PIPING TO THE SUMP MONITOR PROBE. o <br /> 4. - SUMP SENSORS; SENSOR TO BE MOUNTED AT SIDE OF TANK WHERE PRODUCT PENETRATION w N N NZ <br /> INTO SUMP IS MADE AND BELOW LOWEST PENETRATION FITTING WITHIN SUMP AREA. a Mo N � & <br /> I 1 i t s ::. MOUNT SENSOR FLUSH TO BOTTOM OF SUMP. 00 CO 00 zs <br /> `---- --------- 0 --- - ------- y ; ALL TANK SUMP SENSORS SHALL BE DISCRIMINATING FOR THE PRESENCE OF HYDROCARBONS., N rn I I w <br /> � - FLUID CONTAINMENT 20,000 GALLON 36 Y ' L` w` `� " F ¢ ' n Z <br /> x ,> <br /> tF y <br /> DOUBLE WALL UNDERGROUND IN-TANK GAUGE PROBE. 5. - FILL AND VAPOR CAP HEIGHT TO GRADE: THIS DIMENSION IS CRITICAL AND MUST BE ADHERED T0. L0 N N , z <br /> FIBERGLASS STORAGE TANK „ CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK CHARGED FOR w <br /> W/90% OVERFILL ALARM 1/4" THICK STRIKER EXPENSE TO CORRECT INCONSISTENCIES. 0No w d � <br /> DUAL POINT 11 (SEE NOTE #1 & #8) <br /> CALIBRATION. INSTALL PLATE UNDER ALL OPENINGS <br /> DROP TUBE a,= ''a 6. - DROP TUBE CRITICAL DIMENSION: THIS DIMENSION IS CRITICAL AND MUST BE ADHERED T0. <br /> PER MFR'S REQMNT'S. BY TANK MANUFACTURER (TYP CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK CHARGED <br /> r K FOR EXPENSE TO CORRECT INCONSISTENCIES. <br /> FE-PETRO 2 ISP. „x '; 7. - MANHOLE CROWNS: ALL MANHOLE OPENINGS ON THE, TANK SLAB SHALL BE INSTALLED WITH J i <br /> SUBMERSIBLE PUMP 1f ,t ' h", A 2" CROWN OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. Q w <br /> 45 5-1/2" MAX. 8. - METHANOL COMPATIBILITY: FOR ALL METHANOL COMPATIBLE STORAGE SYSTEMS, ALL READILY = <br /> FE-PETRO INTAKE lJ r <br /> (SEE NOTE #6) 6" : , t. ACCESSIBLE COMPONENTS WHICH ARE NOT METHANOL COMPATIBLE FOR THE IMMEDIATE <br /> FILTER SCREEN INTENDED SERVICE SHALL BE RETROFITTED INTO THE STORAGE SYSTEM. <br /> PEA GRAVEL BED & Ar '' , r, 1 X.;+ , i+ ; Axs ' ar } 1._ (r 8 ac <br /> 0 0 <br /> r; ' `' + >,'� ' ;` • �::' r v / ' ` ? i {'", z�`{, � `3ri:� 9. - U.G. CONDUIT: ALL U.G. CONDUIT TO TANKS AND DISPENSERS SHALL BE RIGID <br /> Rti ( <br /> BACKFILL (TYPICAL) <br /> STEEL GALVANIZED (RSG) SCHEDULE 40. CONDUIT MINIMUM BURY DEPTH IS h o. 9� <br /> NOTE: THE TANK FILL END SHALL BE 24" PER CODE. ALL JUNCTION BOXES SHALL BE CLASS 1 DIV. 2 RATED. -00C <br /> ALL ELECTRICAL CONDUIT IN SUMPS SHALL INCLUDE A SEAL-OFF. tc P . <br /> INSTALLED ONE INCH LOWER IN <br /> ELEVATION THAN THE TANK TURBINE END. 2 Tank Section Turbine Sump Section (Tank #3 Only) <br /> C e N <br /> T-Z NOT TO SCALE Q r ~ <br /> T-Z NOT TO SCALE D 0 N <br />
The URL can be used to link to this page
Your browser does not support the video tag.