My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2023 1:00:14 PM
Creation date
11/5/2018 9:19:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2002
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\INSTALL 2002.PDF
QuestysFileName
INSTALL 2002
QuestysRecordDate
7/5/2017 9:39:11 PM
QuestysRecordID
3482255
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CROSS CONNECTION BETWEEN <br /> UNLEADED TANKS, BALL VALVE JOMAR JOM100-700 2" <br /> NORMALLY CLOSED BALL VALVE (TYP.) 54 1g 3/4" RIGID CONDUIT <br /> 30' MANWAY- -- 54 2' BALL VALVE <br /> ONLY (1 ) BALL VALVE O 3) FULL PORT <br /> REQD. BETWEEN TANK (TYP. 2" NPT ELBOW (TYP. *NOTE: ELECTRICAL SEAL-OFF _j m <br /> 48" FIBERGLASSO ) SHOWN IN PLAN VIEW TYP. OF (3) Q <br /> REINFORCED PLASTIC ENVIRON SMA-202044 FOR CLARITY <br /> CONTAINMENT SUMP FE PETRO FEPIST-3 <br /> 41 34 3 2"X2" NPT SWIVEL MALE ADAPTER 2"x12" FLEX CONNECTOR <br /> ENVIRON FEB-3075 2 HP TURBINE (TYP. OF 2) <br /> 33 MALE NPT X MALE SWIVEL NPT w Q <br /> 3/4 FLEX ENTRY® ENVIRON SPC-0200 (TYP.) <br /> BOOT TYP. OF (2) 44 ENVIRON SMA-2020 2" GEOFLEX SWIVEL® Q <br /> 2"X2" NPT SWIVEL MALE ADAPTER PIPE COUPLING (TYP. OF 2) 34 37 ZE HP TRO FE ET- <br /> IS3 2) Z 0 V LL <br /> 3/4 "RIGID CONDUIT 18 (NP ) ENVIRON GDP-45001 40 <br /> ENVIRON SPC-0200 4' GEODUCT (TYP.)O <br /> ELECTRICAL SEAL-OFF 2 SWIVEL COUPLING 30" MANWAY <br /> TYP. OF (2) <br /> (TYP-) ENVIRON GFP-2200 p Z -� Q J <br /> 2" GEOFLEX D 39 O 0 <br /> O0 p 46 ENVIRON GDB-4520 PRODUCT PIPING (TYP.) VEEDER-ROOT Q <br /> 2" NPT ELBOW (TYP.) O O 4"X2' GEODUCT O 36 MAG. 1 PROBE <br /> ENTRY BOOT 2" NPT TEE (TYP.) `� <br /> 2" OVER 3" FRP (TYP. OF (3) ENVIRON GDB-4520 O O FUTURE TURBINE V <br /> '�-4 SIPHON PRODUCT LINE 5 O LOCATION <br /> BETWEEN TANKS #1 & # p ENVIRON GFP-2200 4 ' X 2" GEODUCT46 O <br /> ONLY (1 ) BALL VALVE RE D. O 39 2" GEOFLEX D ENTRY BOOT <br /> FOR ISOLATION O o PRODUCT PIPING (TYP.) (TYP. OF (2) O z <br /> 0 0O O <br /> 0 0 0 p <br /> *NOTE: O ENVIRON GDP-45001 ENVIRON STB 0200 2" 48 ~ V <br /> SHOWN IN PLAN VIEW O 4O 4 GEODUCT (TYP.) TEST BOOT (TYP. OF 2) N <br /> FOR CLARITY ENVIRO GTT-3836 51 <br /> O O ENVIRON GTT-3836 TESTING TUBE TYP. OF 2) N 8 <br /> 2"x12" MALE NPT X MALE SWIVEL 33 51 TESTING TUBE (TYP. OF 3) VEEDER-ROOT <br /> FLEX CONNECTOR 794380-35219 48" FIBERGLASS Q <br /> 3/8" COPPER TUBINGENVIRON STB-0200 DISCRIMINATING SUMP SENSOR 3 REINFORCED PLASTIC <br /> 48 2" TEST BOOT ENVIRON FEB-3075 CONTAINMENT SUMP <br /> (TANK #1 ONLY) TYP, OF (3) 3/4" FLEX ENTRY BOOT 4 <br /> SIPHO CHECK 38 VEEDER-ROOT MAG. (TYP. OF 4) 18 3/4"RIGID CONDUIT <br /> VALVE (TANK1 ONLY) 36 1 PROBE <br /> *TURBINE FITTED WITH "RED JACKET" *ALL SUMPS SHALL BE 56 <br /> 3 GPH MECHANICAL LEAK DETECTOR EQUIPPED WITH AUTOMATIC 80 OZ. <br /> 19 VEEDER-ROOT 794380-352 SNUFFER FIRE EXTINGUISHERS <br /> DISCRIMINATING SUMP SENSOR *CONTRACTOR TO PROVIDE ALL *ALL CONDUIT ENTERING <br /> *ALL CONDUIT ENTERING *ALL SUMPS SHALL BE 56 *CONTRACTOR TO PROVIDE ALL NPT FITTINGS AND NIPPLES SUMPS SHALL HAVE <br /> FOR CONNECTION TO TURBINES SEAL-OFFS INSTALLED. <br /> SUMPS SHALL HAVE EQUIPPED WITH AUTOMATIC 80 OZ. NPT FITTINGS AND NIPPLES <br /> SEAL-OFFS INSTALLED. SNUFFER FIRE EXTINGUISHERS FOR CONNECTION TO TURBINE Tank 3 Turbine Sump Plan *ALL SUMP ENTRIES SHALL <br /> *ALL SUMP ENTRIES SHALL B BE SEALED WITH BULKHEAD FITTINGS <br /> VN <br /> anks #1 and #Z Turbine Sump Plan BE SEALED WITH BULKHEAD FITTINGSNO *PIPE ANGLE AT ENTRY <br /> *PIPE ANGLE AT ENTRY BOOT SHALL NOT EXCEED <br /> OT TO SCALE BOOT SHALL NOT EXCEED A 15 DEG. ANGLE IN ANY <br /> A 15 DEG. ANGLE IN ANY DIRECTION <br /> DIRECTION <br /> 3" BLACK STEEL ELBOWS 3" BLACK STEEL FITTINGS <br /> & NIPPLES (TYP.) <br /> 54 2" BALL VALVE 1 " RIGID CONDUIT 17 14 12 AND BALL3FLOAT VA EXTRACTOR FITTING IN <br /> VALVE NORMALLY OPEN <br /> ENVIRON FEB-3100 1 " 3" BELL X FEMALE NPT <br /> 33 <br /> 2N12" FLEX FLEX ENTRY BOOT TYP. OF 3 7 ADAPTER (TYP.) <br /> 2' x12' FLEX CONNECTOR (TYP.) W <br /> CONNECTOR (TYP.) 33 1/2" BLACK IRON (1 ) PER SUMP \ CJ <br /> 9 0 ELBOW 2" BELL X FEMALE NPT 21 REDUCERT�TMPNjTION TEST _j CJ <br /> W <br /> 2" BELL X FEMALE NPT ADAPTER (TYP.) ENVIRON FEB-7400 Cf) > 00 <br /> ADAPTER (TYP.) 3l8" COPPER TUBING 2" BLACK STEEL ELBOW, 150 LB. SCR'D 3" X 2" TERMINATION TEST 4 ' FLEX ENTRY BOOT W ® Q <br /> TOO SIPHON CHECK 21 TYP. <br /> 3" X 2" TERMINATION TEST 21 VALVE AT MASTER TURBINE REDUCER (TYP. <br /> REDUCER (TYP. ) <br /> „ENVIRON FEB-6300 2" X 1/2" HEX BUSHING ENVIRON FEB-6300 BO © 2 W <br /> 3 FLEX ENTRY BOOT 2 AND CLOSE NIPPE 3" FLEX ENTRY BOOT VEEDER-ROOT A.O. SMITH 3" FIBERGLASS Q = <br /> TYP. TYP DISCRIMINATING SUMP SENSOR / VAPOR RETURN LINE INSIDE <br /> 4 ' FIBERGLASS SECONDARY 0 -I <br /> CONTAINMENT (TYP.) U 0 <br /> -*---- 2" TEE, 150 LB. SCR'D, GALV. <br /> 48" FIBERGLASS 3 5 A.O. SMITH 2" FIBERGLASS 3/4" RIGID CONDUIT 18 J ® � <br /> A.O. SMITH 2" FIBERGLASS 5 -_ 36 3 48" FIBERGLASS REINFORCED PLASTIC SIPHON LINE , INSIDE 3" <br /> s CONTAINMENT SUMP <br /> SIPHON LINE INSIDE 3" REINFORCED PLASTIC FIBERGLASS SECONDARY 28 3"X18" MALE NPT X MALE NPT <br /> FIBERGLASS <br /> TSECONDARY <br /> CONTAINMENT SUMP FROM TANK #1 4 FLEX CONNECTOR <br /> \ / — <br /> 7---- 11 4" FILL TUBE OPENING <br /> i 3" UNION 48" FIBERGLASS <br /> 4"x2" DOUBLE 52 2" BLACK STEEL SIPHON 4 REINFORCED PLASTIC <br /> 4"x2" DOUBLE 52 2" BLACK STEEL SIPHON TAPPED BUSHING STINGER. EXTEND TO WITHIN CONTAINMENT SUMP <br /> tL <br /> TAPPED BUSHING STINGER. EXTEND TO WITHIN 6" OF BOTTOM OF TANK. <br /> 6" OF BOTTOM OF TANK. <br /> *ALL SUMPS SHALL <br /> BE <br /> NOTE: NOTE M C <br /> EQUIPPED WITH AUTOMATIC S <br /> SLOPE SIPHON LINE OZ. <br /> 2 * SLOPE SIPHON LINE <br /> DOWN T TANK SNUFFER FIRE EXTINGUISHERS <br /> # CONTRACTOR TO PROVIDE ALL UP TO TANK 1 <br /> " *ALL CONDUIT ENTERING <br /> MINIMUM OF 4" NPT FITTINGS, NIPPLES AND TUBING MINIMUM OF <br /> SUMPS SHALL HAVE <br /> FOR CONNECTIONS TO SIPHON <br /> SEAL-OFFS INSTALLED. <br /> *ALL SUMP <br /> 1 <br /> ES SHALL <br /> Tank 1 Siphon Detail 2 Tank 2 Siphon Detail E Fill End Sump Plan (All Tanks) BE SEALED WITH IBU BULKHEAD FITTINGS <br /> T-4 NOT TO SCALE T-4 NOT TO SCALE *PIPE ANGLE AT ENTRY <br /> T-4 NOT TO SCALE BOOT SHALL NOT EXCEED <br /> A 15 DEG. ANGLE IN ANY <br /> DIRECTION <br /> A.D. SMITH 4" <br /> a <br /> "CLAMSHELL" TEE <br /> NOTE: <br /> OR 90' WHERE z > z <br /> INSTALL 4"X3" TESTAPPLICABLE <br /> . REDUCERS AT FILL SUMPS A.O. SMITH 2" FIBER- <br /> FOR TESTING SECONDARY 13 OPW 523 VENT CAP GLASS VAPOR RETURN <br /> LINE INSIDE 3" FIBERGLASS 25 0 o vs g <br /> SECONDARY (TYP.) $ o <br /> 9 N <br /> 3"0 GALV. SCH. 40 VENT PIPE 3" FIBERGLASS VAPOR <br /> RETURN LINE INSIDE 6 ENVIRON 2" GEOFLEX D PRODUCT <br /> z o <br /> PAINT PER G-70-150-AE WHITE 4" FIBERGLASS SECONDARY 39 40 SUPPLY LINE INSIDE 4" GEODUCT (TYP.) <br /> 3" BLACK STEEL USE ITR-3020 FOR SPACERS ° <br /> RISER (PAINT N GALV. UNI-STRUT SUPPORT AS REQUIRED A.O. SMITH 4" TO 3" <br /> WHITE) BRACKET PAINT WHITE COMPACTED BACK FILL PAVING VARIES F.R.P. CONCENTRIC <br /> AS SPECIFIED REDUCER N <br /> 20 MIL. WRAP TO6"-6'x40 GALV. STEEL POST <br /> 12" ABOVE GRADE PAINT WHITE A.O. SMITH 3" FIBERGLASS <br /> NYLON BAND CLAMP <br /> _.._ VAPOR RETURN LINE INSIDE 26 0 ? � <br /> EXPLOSION PROOF J-BOX w 4' FIBERGLASS SECONDARY a <br /> GRADE d MOUNTED TO POST O Z (TYP.) _ o <br /> 4"X3" REDUCER Zs o 0 0 0 0 0 0 <br /> DONUT SEAL OFF ED 00(�0� ) OU <br /> ��, nnD�,oDonn ,,onn ,,o Z � <br /> GRADE [Ifo o o o o`er 0 0`0 'CLDo 00 ( 00 z <br /> LL� 00 0 000 000 00000 <br /> 28 3"X18" MALE X MALE � c�- z ° I Ww <br /> O�O O o O V O 1-bo N ¢ t� tf7 Z <br /> UD Ln <br /> FLEX CONNECTOR n ,, (� � (�,(� n nr, <br /> 3" FRP VENT LINE INSIDE 4" FRP xa 0000 0 0 000 00000 A.O. SMITH 4" 9 w a zZ <br /> 3" BLACK STEEt 26 ECONDARY. SLOPE TO TANK AT D + AID0 ` oO V O OCCo ORP0 0 "CLAMSHELL° ELLC.11 z <br /> COUPLING 4"X36" FLEX BOOT / w: 0000 0000 O 00 O oO00 0 OR 90' WHERE o ° 00 Y � N <br /> 1 4' PER FOOT o o n ,, APPLICABLE. <br /> "CRUSHPROOF" 450036 "j o 0000 00000 <br /> NYLON BAND CLAMP 3/4" CONDUIT w PULL STRING z� � z Oon0,,0n-,,0n0,,0n0 n0,-,000 0n00n0�,0 ! <br /> TO CONTROLLED ENCLOSURE o CY014P01 P0`� 0�0`1000 0`0 0 o ° VN �N� 's <br /> 3 BELL X FEMALE 6�� <br /> NPT FRP FITTING TO TANKS 12"0x3' CONC. POST FOOTING I—I —III-11I III II III-1I —III—III- o ? <br /> ° o Q <br /> 4' 90° CLAMSHELL ELEVATION TANK #3 PRODUCT LINE _ <br /> TANKS #1 AND #2 PRODUCT <br /> 3" PRIMARY FRP PLAN LINE UNDISTURBED SOIL OR COMPACT TO 95% <br /> Q <br /> 4" SECONDARY FRP �OA��BAS, q b8 o coos <br /> SECTION 15" 15" NOTE: ALL PIPING TO SLOPE TO TANKS 1/8" PER FOOT yQ�P`' y Ey <br /> 30,> w °' iso ; m <br /> G Typical Piping Burial H Typical Fiberglass Reinforced Pipe Fittings P <br /> p Vent Stack Detail - T-4 NOT TO SCALE <br /> T-Q NOT TO SCALEg7r C1V11 , xP O f1- <br /> T-4 NOT TO SCALE �Cp�Fc� � T <br />
The URL can be used to link to this page