Laserfiche WebLink
STATE OF CAU FORMA <br /> STATE WATER RESOURCES CONTROL BOARD _ <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br /> MARK ONLY 1 N PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION a 7 PERMANENTL SITE <br /> ONE REM ❑ 2 RIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ e TANK REMO D <br /> DBA OR FACILITY HERE TANK IS INSTALLED: .ST S O 15111 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNERS TANK I.D.6 -f it 8. MANUFACTURED BY: V--t N <br /> C. DATE INSTALLED(MO/WY/YEAR) I 0�-1 D. TANK CAPACITY M GALLONS: <br /> II.TANKg6NTENTs IFA4ISMARKED,COMPLETE ITEM C. <br /> 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. IIIREGULAR 3 DIESEL E] S AVIATION GAS <br /> UNLEADED <br /> A ❑ 2 PETROLEUM 60 EMPTY ❑ 1 PRODUCT E31b PREMIUM El 4 GASAHOL 7 METHANOL <br /> UNLEADED 5 JETFUEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN 2 WASTE ❑ 2 LEADED 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.v: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B,AND C.AND ALL THAT APPLIES IN BOX <br /> A. TYPE OF ,❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER 95 UNKNOWN <br /> IJ/ <br /> SYSTEM 2 SI LE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK 1 BARESTEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS E:] 4 STEEL CLAD W1 FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ B 100% METHANOL COMPATIBLE W/FRP <br /> (Primary TaMt) ❑ 9 BRONZE 110,,,`(((GALVANIZED STEEL ❑ 96 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED -"KYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR O 5 GLASS LINING 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER I f Il <br /> LINING <br /> c <br /> 13 LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2,qQAfING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U N OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH U as UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 6 100% METHANOL OOMPATIBLEW/FRP <br /> PROTECTION A U B GALVANIZED STEEL A U 10 CATHODIC PROTECTION 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIOHTNESSTESTING ❑ 3 NTERORNG C::]99 OTHER <br /> MONV.TANK LEAK DETECTION <br />//'� <br /> ((ff F-11 VISUAL CHECK 2 INVENTORY RECONCILIATION ❑ 3 VAPOR MONITORING❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br />< KI <br /> 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ W OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST (MO/DAWY{i) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES NO� <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL] <br /> THIS FORM HAS BEE COMPLETED UNDER PENAL TV OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> IrM9NTED4BIDN nMI, <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY N JURISDICTION 6 FACILITY 6 TANK 6 <br /> STToo' G 0 ® = LOJ0111 %01;P� <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE J/7 g PERMIT EXPIRATION DATE I' 1 <br /> FORM B (aqm THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. '^1 <br /> FORUCAB M <br /> ..i�f /oh (5� <br />