BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FLOOD
>
23390
>
2300 - Underground Storage Tank Program
>
PR0503070
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2021 2:51:34 PM
Creation date
11/5/2018 9:45:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0503070
PE
2381
FACILITY_ID
FA0005674
FACILITY_NAME
OM SCOTT & SONS/HYPONEX CORP
STREET_NUMBER
23390
Direction
E
STREET_NAME
FLOOD
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
093-100-17
CURRENT_STATUS
02
SITE_LOCATION
23390 E FLOOD RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FLOOD\23390\PR0503070\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/3/2013 8:00:00 AM
QuestysRecordID
153129
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. .� <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWALPERMIT ❑5 CHANGE OF INFORMATION ❑7 ERMANENTLY CLOSED TANK 10 <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE 6 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ( iry4,01, FARM TANK-YES❑ NO <br /> EgN <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY N <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ i MOTOR VEHICLE FUEL ❑2 PETROLEUM B. C. ❑1 UNLEADED ❑2 LEADED ❑3 DIESEL <br /> F-13 CHEMICAL PRODUCT ❑4 OIL ❑ 1 PRODUCT <br /> ❑4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> F-15 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN REM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A.B,C,&D <br /> A TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> F-1I STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CUD W/FIBERGLASS REINFORCED PUISTIC <br /> B.TANK ❑ <br /> MATERIAL5 CONCRETE ❑6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑8100%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C.INTERIOR ❑ I RUBBER LINED ❑2 ALKYD LINING ❑3 EPDXY LINING ❑4 PHE14OUCLINING <br /> LINING ❑5 GLASS LINING ❑6 UNUNED ❑ 95 UNKNOWN <br /> ❑IS UNING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYEIHLENE WRAP ❑2 TARORASPHALT ❑3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U / SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLEWALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U S ALUMINUM A U 6 CONCRETE A U 7 STEELCLAD W/FRP A U 6 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZEDSTEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S t VISUALCHECK P 8 2 INVENTORY RECONCIUATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P 3 6 PRECISION TESTING P 8 7 PRESSURE TESTING P 8 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OF3.WAS TANK FILLED WITH <br /> GALLONS <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> Eql = <br /> CURRENTLOCAL AGENCY 2 FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CXECKX PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FDRM B(6-29-66) THIS FORM MUST BE ACCOMPANIED BY A' (TY/SIiE APPLICATION, FORM'A',UNLESS A CURRE FORMA' HAS BEEN FILED <br /> `� DATA PROCESSING COPY <br />