MINIt%,,,,M VERIFICATION LABORATORY ANArCSIS
<br />analysts methods are the designated EPA methods described in EPA SW 846, Third Edition. Those methods not found in SW
<br />846 are specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix D (B), Table 3-5 on page A20 for
<br />minimum detection limits for motor vehicle fuel (gasoline and diesel). Refer to "Tri -Regional Board Staff Recommendations for
<br />Initial Evaluation and Investigation of UST's" for the waste and motor oil minimum detection limits.
<br />Detection Limits that remain below the MCL, STLC or Allowable Limit of the contaminant in question will be accepted,
<br />however laboratory shall utilize the most conservative method.
<br />LABORATORY ANALYSES TERMINOLOGY
<br />TPH-G
<br />Total Petroleum Hydrocarbon, Gasoline, GC/FID (5030) 8015 mod or GUMS 8260
<br />TPH-D
<br />Total Petroleum Hydrocarbon, Diesel, GC/FID (3550), 8015 mod or GUMS 8260
<br />BTX & E
<br />Benzene, Toluene, Xylene & Ethyl Benzene, GC(PID 8020 or GC/MS 8260
<br />CL HC
<br />Chlorinated Hydrocarbon, GC/HSD 8010, GC/MS 8240 or 8260
<br />OXYGENATES
<br />Total lead, AA 7420, AA 7421 or ICP -AES 6010
<br />OXYGENATES
<br />TANK
<br />TANK
<br />TPH-G
<br />TPH-D
<br />BTX & E
<br />CL HC
<br />TOTAL
<br />MTBE
<br />(MTBE,
<br />METALS
<br />PCB
<br />#
<br />CONTENTS
<br />8015
<br />8015
<br />8020
<br />8010
<br />LEAD
<br />8020
<br />TBA,DIPE,
<br />ICAP/
<br />8270
<br />8260
<br />8260
<br />8260
<br />8240
<br />7420
<br />8260
<br />TAME)
<br />S or
<br />AA
<br />8080
<br />8260
<br />7421
<br />8260
<br />LEADED GAS
<br />X
<br />X
<br />X
<br />X
<br />UNL GAS
<br />X
<br />X
<br />X
<br />DIESEL
<br />X
<br />X
<br />ROSENE
<br />X
<br />X
<br />X
<br />UNK FUEL
<br />X
<br />X
<br />X
<br />X
<br />X
<br />rlton—o—,L-�
<br />I X
<br />X
<br />X
<br />CHLOR.
<br />SOLVENTS
<br />X
<br />X
<br />X
<br />NONCHLOR
<br />SOLVENTS
<br />X
<br />X'
<br />X
<br />STE\
<br />FUWSI
<br />L
<br />ED OIL
<br />X
<br />X
<br />X
<br />X
<br />X
<br />X
<br />X
<br />analysts methods are the designated EPA methods described in EPA SW 846, Third Edition. Those methods not found in SW
<br />846 are specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix D (B), Table 3-5 on page A20 for
<br />minimum detection limits for motor vehicle fuel (gasoline and diesel). Refer to "Tri -Regional Board Staff Recommendations for
<br />Initial Evaluation and Investigation of UST's" for the waste and motor oil minimum detection limits.
<br />Detection Limits that remain below the MCL, STLC or Allowable Limit of the contaminant in question will be accepted,
<br />however laboratory shall utilize the most conservative method.
<br />LABORATORY ANALYSES TERMINOLOGY
<br />TPH-G
<br />Total Petroleum Hydrocarbon, Gasoline, GC/FID (5030) 8015 mod or GUMS 8260
<br />TPH-D
<br />Total Petroleum Hydrocarbon, Diesel, GC/FID (3550), 8015 mod or GUMS 8260
<br />BTX & E
<br />Benzene, Toluene, Xylene & Ethyl Benzene, GC(PID 8020 or GC/MS 8260
<br />CL HC
<br />Chlorinated Hydrocarbon, GC/HSD 8010, GC/MS 8240 or 8260
<br />TOTAL LEAD
<br />Total lead, AA 7420, AA 7421 or ICP -AES 6010
<br />OXYGENATES
<br />MTBE, ETBE, TAME, D1PE, & TBA GC/MS 8260 (For MTBE screen not you may use 8020)
<br />METALS ICAP or AA
<br />Inductively Coupled Plasma Atomic Emission Spectrometry6010 or Atomic Absorption Spectrometry 7000.
<br />Metals: Cadmium, Chromium III and VI, Lead, Zinc and Nickel.
<br />PCB
<br />Polychlorinated Biphenyls, GUMS 8270 or 8080
<br />GC -FID
<br />Gas Chromatography, Flamc Ionization Detection
<br />Method 3050
<br />Acid digestion
<br />Method 3540
<br />Soxhlet sample preparation
<br />Method 3550
<br />Sonication sample preparation, extraction method
<br />Method 5030
<br />Purge and trap sample preparation
<br />QA/QC
<br />Quality Assurance/Quality Control
<br />Noles; To avoid ftll5c positive dejec11011 orbeize le, benzene -Bee 301"1113 Ole to be used. Fused cbpilluty culuuuls ure plererreJ to puekcJ
<br />columns; a packed column maybe used as a "Orsi cut" with "dirty"
<br />is followed. samples or once the hydrocarbons have been characterized and proper QA/QC
<br />For drinking water sources, EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the
<br />detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination may require further analysis. EHD
<br />recommends holding those samples until diiposal is indicated.
<br />EH 23 046 (Revised 3/15/02) Page 8
<br />
|