My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1994
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1401
>
2300 - Underground Storage Tank Program
>
PR0231782
>
REMOVAL_1994
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2021 1:02:06 PM
Creation date
11/5/2018 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1994
RECORD_ID
PR0231782
PE
2381
FACILITY_ID
FA0003820
FACILITY_NAME
VALLEY WHOLESALE DRUG
STREET_NUMBER
1401
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13525031
CURRENT_STATUS
02
SITE_LOCATION
1401 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\1401\PR0231782\REMOVAL 1994.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN CCn,n i PUBLIC HEALTH SERVICES/ENVIRONMENTAL HEAL n. JIVISION <br /> 1. UGST WORKSHEET FOR SITE CLOSURE EVALUATIONDATE -7 _Z _9Lf <br /> NAME OF FACILITY vt � d,V% SWEEPS CODE M Z3 <br /> ADDRESS ll - ,�y,�, TANK ID # <br /> TANK SIZE ` V FUEL TYPE Y u, 1 <br /> 11. GENERAL SITE HISTORY <br /> set <br /> Is permit current? Yes No Permit # - /�-�; Z Facility Status Code 0 D00.SOLI/GW Cont Yes No <br /> Number of Tanks at facility � Age of Tanks(if available) 2 p (5 Type of Tank Steel Fbrgl Sngl Dual <br /> III. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test 7 Yes No V If yes, give date(s) <br /> Was a repair made to the tank system? Yes No If yes, what was repaired? Uln /i/; <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No STXE TPH-G TPH•D Pb/EDB <br /> TYpe of failure/discharge catastrophic long-term leakage overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INS P#TION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes N Depth to Ground Water I D Ref/Year r; 8 Average Annual Precipitation A= 14 10-25 <br /> On-Site WetL(s) Yes No 14 Number & Type Irr Dom Pub <br /> S Score 5 Score S Score <br /> Distance to WeLL(s) from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is met E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) /C) (Z1�2' -100 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase Vertical migration <br /> of leachate (i.e., septic systems, water wells, ponds) None Unknown Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least More than <br /> XxxxxX None one one <br /> air / mntfi� C4 - <br /> - COLUMN TOTALS>>>TOTAL POINTS + + - <br /> SanpLa Result: (B T % OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or less <br /> NlceS{ are; <br /> 7�h1 85ff" )( "12OOep`A B T % E B T X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. I. <br /> NA\3 <br /> Sample Result: GASOLINE 1000 100 10 <br /> MAXIMUM ALLOWABLE TPH LEVELS (PPM) <br /> TPH DIESEL 10,000 1000 100 <br /> FOOTNOTES: ...If documented soil and/or ground water contamination is present, do not complete the Leaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. S7AF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX & E or TPN Concentrations > Al owable Levels 'Yes No T= <br /> E: ISaFFb JJ G(�f <br /> 2. Recommend Site Closure Yes No `If Yes, Refer to Site Mitigation for Evaluation x lBD A ' <br /> VII. REVIEW EVALUATION . TO BE COMPLETED BY A SUPERVISOR/SENIOR , 1�71f= U l(/ M <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES INC[' REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / 2/ DATE-CLOSURE LETTER MAILED <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.