Laserfiche WebLink
� ma <br /> — REVISIONS BY �A <br /> �X . <br /> f�r <br /> T1 <br /> ELECTRICALELECTRiCAL INSTALLATION SHALL BE IN ACCORDANCE WITH MOST <br /> RECENTLY ADOPTED EDITION OF N.E C., STATE OF CALIFORNIA TITLE 24• PART EXISTING JOINT UTILITY POLE <br /> 3• AND ALL APPLICABLE LOCAL_ CODES. )-y-A2� --- <br /> 2. ELECTRICAL CONTRACTOR SHALL VERIFY POWER AND PHONE SERVICES AT <br /> 517E PRIOR r0 BIDDING. SERVICE TO CONFORM TO UTILITY CO. REQUIREMENTS. <br /> ELECTRICAL CONTRACTOR SHALL ARRANGE FOR SERVICE INSTALLATION PER <br /> J <br /> UTILITY COMPANY REQUIREMENTS AND PAY ALL CUSTOMER CHARGED SERVICE <br /> COST5. / LOCKABLE MANUAL <br /> MOTOR DISCONNECT/� r - <br /> / �_ r ^At xx <br /> 3. ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, STARTER <br /> ""11» 12 <br /> LICENSES, ETC. REQUIRED 'f0 CARR'( ON AND COMPLETE THE WORK. 24 <br /> 4. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, G_ t<s ap ` <br /> fCIDENT L TION AND PERFORM ALL OPERATIONS NECESSARY "EL ANY REASONABLE I t .. <br /> INCIDENTAL TO PROPER EXECUTION AND COMPLETION OF ALL "ELECTRICAL WORK" <br /> /— .PR!PAN2EFUEL TANK <br /> WHETHER SPECIFICALLY MENTIONED OR NOT; ALL AS INDICATED, SPECIFIED WITH METERING PUMP <br /> HEREIN, AND/OR IMPLIED THEREBY iO CARRY OUT THE APPARENT INTENT P'L <br /> THEREOF <br /> Px <br /> s/Al b <br /> 5 ALL ELECTRICAL MATERIALS SHALL BE NEW AND USTED WITH THE <br /> UNDERWRITERS LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND c is <br /> SHALL BEAR THEIR LABEL WHEREVER STANDARDS HAVE BEEN ESTABLISHED AND . <br /> LABEL SERVICE IS REGULARLY FURNISHED BY THAT AGENCY, <br /> 6. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE f <br /> S1ZE AND LOCATIONS OF EQUIPMENT ARE SHOWN i0 SCALE WHEREVER POSSIBLE. - (! EXISTING 041LOWC WITH <br /> CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND EXISTING BUILDING <br /> IT I1 <br /> VERIFY THIS INFORMATION AT THE SITE CONTRACTOR SHALL BE RESPONSIBLE THE ELECTRICAL. CONTRACTOR 1 REMAIN IN OPERATION <br /> FOR LAYING OUT AND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH I SHALL COORDINATE WITH THE - <br /> OTHER TRADES. - OWNER AND UTILITIES TO DISCONECT <br /> SERVICES TO BUILDING AND CONNECT - e <br /> 1. CONDUCTORS SHALL U COPPER CONDUCTORS TYPE THHN/THWN FOR #B OR - — Y NEW BUILDING i0 MINIMAE OUTAGES - <br /> SMALLER AND COPPER GONDI�CTORS NPF. iHW FOR )J6 OR LARGER UNLESS OTHERWISE - <br /> o1 <br /> NOTED OR REQUIRED BY CODE. - �p <br /> �._. . <br /> B. ALL LUMINAIRES AND BALLASTS SHALL BE CERTIFIED BY THE MANUFACTURER <br /> TO THE CALIFORNIA ENERGY COMMISSION. ALL FLUORESCENT FIXTURES TO BE <br /> LAMPED WITH ENERGY SAVING LAMPS OR APPROVED EQUAL, AND HAVE AN ENERGY I - <br /> SAVING °A" SOUND RATED ELECTROMAGNETIC BALLAST OR APPROVED EQUAL UNLESS I , T <br /> OTHERWISE SHOWN. ALI_ HID LIGHT FIXTURES SHALL HAVE HIGH POWER FACTOR <br /> BALLASTS. - __._..._._... _. _..,.-...._ <br /> .4 <br /> 9. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL PLANS FOR .SEE E--2 FOR � �{: L2-2# <br /> EXACT LOCATION OF ALL HVAC UNITS AND DEVICES. FURNISH AND INSTALL_ ALLSEE <br /> PLAN I <br /> CONDUITS AND LANE VOLTAGE WIRING (LOW VOLTAGE WIRING BY OTHERS) TO HVAC OF GAS ISLANDS AND --t <br /> EQUIPMENT AND ASSOCIATED CONTROLS AND DEVICES AS SHOWN ON THE ELECTRICAL. I t M <br /> AND MECHANICAL- PLANS UNLESS OTHERWISE NOTED. LIGHT-INC, EXISTING <br /> BUILDING <br /> 10- FLASH AND COIJNTERFlASH ALL ITEMS PAS5ING THROUGH THE ROOF. TO BE <br /> I DEMOLISHED <br /> IT. WORK SHOWN ON THE DRAWINGS TO BE INSTALLED UNDERGROUND SHALL BE <br /> INSTALLED AT LEA.Sf 24' BELOW GRADE BACKFILL IN 6" (HICK, PROPERLY. t <br /> MOISTENED LAYERS, SOLIDLY PACKED AND IRON TAMPED f0 A DENSITY NO! I 1 <br /> LESS THAN THAT OF ADJACENT, UNDISTURBED EARTH RESTORE SURFACES, 1 <br /> ROADWAYS, WALKS, CURBS. WALLS, EXISTING UNDERGROUND INSTALLATIONS TO I 5 <br /> ORIGINAL CONDITION IN AN ACCEPTABLE MANNER. ��, <br /> 12. MINIMUM CONDUIT SIZE FOR SITE LIGHTING SHALT_ BE 3/4• .AND MINIMUM <br /> WIRE SIZE SHALL BE #10 UNLESS OTHERWISE SHOWN. (�,yyf <br /> • I"-- " - -- "--- """- '� ELECTRICAL CONTRAQT R 4,NALL,COORDINATE_ WITH <br /> hh - p I• <br /> THE OWNERS:NEON $iGN-LIGHTING SUPPLIER. <br /> t7 C� <br /> COORDINATE WITIH OWNS 'THE INSTALLATION <br /> OWER N 4F TH 3^+ <br /> - I ev § <br /> J NEON PRIOR TO BID: ; MAKE ALL POWER y7s. <br /> CONNECTIONS OP �iDIL EI.ECTR CALF"6ISOLATF.O I ur <br /> f_- t2-20 WIRE IN A JUNGT)ON BOX BEHIND THE PARAPIT <br /> - _ FOR CONN0TICN PY, TAE NEON SUPPLIER, <br /> \4 - tVi <br /> C'T.T <br /> I <br /> R Rt <br /> 4Lt <br /> �� <br /> +- <br /> CONTRACTOR TO PROVIDE, <br /> - TRANSFORMER PqqD AND BARRIER <br /> UTILITY COMPANY REQUIREMENTS POSTS PER PC, E. RED'TS \ <br /> Lz-t7.ztas <br /> NEUTRAL+2#10 GNU " r .. _. ._. _ �. •- `� - --'•' A': <br /> COMPAN R AI. UT!LITYREPRESENTATIVES <br /> cpMPANYCOOR REQUCOORDINATE <br /> AND Px 'MD, UTILITY / THE CONTRACTOR SHALL COORDINATE ______. — <br /> ("Y l -- - - {1 WITH P,G,&F., PAC BELL AND CABLE <br /> COMPANY REPRESENTATIVES. C(`ORO,NAfF ANO PA'v OWNEF/SER`dCE LZ 18 <br /> • Ft <br /> — STARTUP axD POWER LL _ __ __J 1V COMPANY TO RELOCATE. EXISTING -- <br /> ELECTRICAL CONTRACTOR TO MAKE ALL ,� OVERHEAD WIRE TO AVOID CROSSING <br /> 0,. . FOR BJI ON <br /> --_ POWER CONNECTIONS (0 THE UNION 76 �- -' � � , • 't'• t°u" <br /> X UTILITY PACIFIC CAS AND ELECTRIC SIGN. COORDINATION INSTALLATION OF ._/ CENTER OF PROPERTY AND PARKING I �J �, " � (2)5"CO <br /> W ADDRESS. 4040 WEST LANE - THE SIGN WITH THE GENERAL AND THE �� AREA. ---- {}-.. -_..__._-_.___. ty) <br /> �-{ <br /> ADDRESS: STOCKTON, CA OWNER P1 112 CO TELEPHONE 'f ✓r - <br /> O CONTACT: PAUL GOMEZ `'� 17_2 <br /> II 2"CO CABLE TV <br /> d PHONE 209-342-1M194 (E) StREET LIGHT � I <br /> = UTILITY PACIFIC BELL <br /> OK p <br /> //`<l —DRIVE-iHRU Slr„lI <br /> ADDRESS. 44 W. YOKUTS, IST FLOOR � C\ � �J 1-2-24 <br /> � t <br /> O \ / <br /> ADDRESS STOCKTON, CA 95207 / 111 <br /> CONTACT JOHN KOZINA - `- - -- .- - - P2 _ -. - O4'C-2 H10+i 10 GND I - - rJ rx• <br /> (\ 374335 -� - _. - . ... . _ l� P1 7 SWITCH AT RIVE UP 2 <br /> \\\/ <br /> F- PHONE: (209) 474-4727 (E) PAYPHONES PND i �o -. <br /> TRAFRCE CONTROL BOXES - - <br /> x/250 W <br /> UTILITY: MEDIA ONE a <� 1`CO <br /> ADDRESS: 6505 TAM O•SHANTER DRIVE STUB UP AND �`- <br /> ADDRESS STOCKTON, CA 95210 <br /> m CAP TOR FUTURE <br /> a CONTACT: DOUG KYLER <br /> v PHONE: <br /> ---` - ”—'—'----'--- �.J �— EXISTING •JOINT UTILITY POLE 3/4"C -2))10}1#10 GN O x' - - - i <br /> TYPICAL FOR ALL \ 0 <br /> ____ _\� <br /> SITE LIGHTING CONDUITS - DRIV[-THRU SIGN � _ � <br /> \-- EXISTING STREET O R® STREET tL x TrdS1 <br /> LIGHT TO REMAIN <br /> 4 <br /> $ 9 2-2. -G8 1 a <br /> Na. 114303 <br /> CAO. 6...30-Ot * GATE 5- , <br /> �T9l YeCTR\OP��S '�CNf. <br /> `^O!''CAUf04A AS NOTED hx� <br /> GRAwNELK <br /> HCS ENGINEERING, INC. °B 97311 <br /> (`'''�� fin\ d r. <br /> Al _EL. _E_C_TR_ ! CAL I � PLAN <br /> , �� CONSULTING ELECTRICAL ENGINEERS <br /> QUAIL LAKE=5 DRIVE <"1 � <br /> 1 �=10, REFERENCES 16000 <br /> 4651 QST'OCKTON, CA 95207 (209)47$` $270 e <br /> 2F SHEETS SR . <br /> (:\MILLER KLEIN GREWALS\Et DWa) <br /> 4 <br />