Laserfiche WebLink
4.0 DRILLING AND SOIL TESTING <br /> Drilling and sampling were performed to determine the presence of any <br /> contamination to the surrounding soil should the tank have leaked. Four <br /> borings were drilled at each corner around the tank periphery. The drilling <br /> was performed after visual inspection of the tank indicated no apparent <br /> leakage from or damage to the tank. The age of the tank is estimated to be ? I9"lam <br /> about six years old. Drilling permits were obtained from the San Joaquin <br /> County Health District. Copies are provided in Appendix V. As required by <br /> the permit, a copy of this report is provided to the client for forwarding to <br /> ` the local Health Authority. <br /> The borings were drilled on a 15° angle from vertical to intercept the <br /> backfill of the tank and obtain samples from the area directly beneath the <br /> ` tank. The sampling scheme is shown in Figure 4. The borings were backfilled <br /> with a concrete grout and finished to conform with the surface grade. Boring <br /> logs are presented in Appendix IV. <br /> ` The samples were sent to the IT Stoner Laboratory, Santa Clara, California for <br /> analysis. The results indicated high levels of contamination which were <br /> inconsistent with visual observation. The client was informed of this fact <br /> and that a laboratory mix-up was suspected. A decision was therefore made to <br /> ` redrill four more borings in order to obtain new samples. <br /> All samples were taken by using a 2" diameter standard penetrating sampler <br /> with brass liners, driven 18-inches. The samples were taken at depths of <br /> ` approximately 10, 15 and 20 feet as shown on the boring logs. The samples <br /> were packed in ice and shipped to the IT-Stoner laboratory, Santa Clara, <br /> California, under standard chain-of-custody procedures. The samples were <br /> analyzed for total petroleum hydrocarbons by solvent extraction and gas <br /> chromatography. The samples were analyzed for lead by McIntosh Laboratories <br /> and none was detected. The certified analytical results appear in Appendix VI <br /> and Table I. <br /> 4 <br /> ENG:0551/02246 <br />