My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1986
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4343
>
2300 - Underground Storage Tank Program
>
PR0232095
>
REMOVAL_1986
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2021 1:29:09 PM
Creation date
11/5/2018 10:08:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1986
RECORD_ID
PR0232095
PE
2381
FACILITY_ID
FA0010425
FACILITY_NAME
Pacific Paper Tube
STREET_NUMBER
4343
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
4343 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\4343\PR0232095\REMOVAL 1986.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
If If If If <br /> ° SAFE HANDLING PAGE 1 OF 2 SAFE HANDLING PAGE 2 of 2 <br /> AND AND <br /> DISPOSAL INFORMATION DATE:OS/S4 DISPOSAL INFORMATION DATE:OS/84 <br /> SUPERSEDES:03/76 ° SUPERSEDES:03/76 <br /> ZEP MANUFACTURING COMPANY (EQUIVALENT TO U.S. DEPT. PRODUCT NO.0306 ZEP MANUFACTURING COMPANY (EQUIVALENT TO U.S. DEPT. PRODUCT NO. 0306 <br /> RSI/N MAINTENANCE AND SANITAl10N OF LABOR OSHA FORM 20. ) ZEPSTART FIpSTIN MAINTENANCE AND SANITATION DF LABOR OSHA FORM 20. ) ZEPSTART <br /> CTION I — E M E R O E N C Y C 0 N T A C T S SECTION VI — REACT I V I T Y D A T A <br /> P MANUFACTURING COMPANY NON—OFFICE HOURS.WEEKENDS,HOLIDAVS: STABILITY: STABLE <br /> O. BOX 2015 (404)252-1587,(404)435-2973, (404)351-2952(404)971-3367 INCOMPATIBILITYf AVOID): STRONG OXIDIZERS AND CERTAIN PLASTICS <br /> LANTA.GEORGIA 30301 LOCAL POISON CONTROL CENTER TELEPHONE.. . ... . ... POLYMERIZATION: WILL NOT OCCUR <br /> LEPHONE(404)352-1680 TRANSPORTATION EMERGENCY HAZARDOUS DECOMPOSITION: <br /> TWEEN 8:ODA,M. -5:OOP.M. CHEMTREC: TOLL FREE 1-800-424-9300 ALL CALLS RECORDED CO2 <br /> ASTERN TIME ZONE) DISTRICT OF COLUMBIA (202)483-7616 ALL CALLS RECORDED <br /> CTION 11 — H A Z A R D O U S I N G R E D I E N T S CAS REGISTRY NO. % SECTION VII — S P I L L D R L E A K P R 0 C E D U R E S <br /> ETHYL ETHER 60-29-7 > 90 STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED <br /> LARGE SPILLS ARE UNLIKELY DUE TO AEROSOL PACKAGING. IF SPILLED, ABSORB WITH <br /> AN ABSORBENT MATERIAL (i. e. ZEP—O—ZORD)I PICK UP AND DEPOSIT IN SEALABLE <br /> CONTAINER FOR DISPOSAL AS HAZARDOUS WASTE. THOROUGHLY CLEAN SPILL AREA WITH <br /> DETERGENT SOLUTION. RINSE THOROUGHLY WITH CLEAN WATER. <br /> WASTE DISPOSAL METHOD <br /> PRODUCT IS CONSUMED IN USE. WHEN DISPOSING OF SPENT CONTAINERS, DO NOT CRUSH, <br /> PUNCTURE OR INCINERATE. IN MOST STATES, QUANTITIES TOTALING LESS THAN 2.200 <br /> POUNDS OF HAZARDOUS MATERIALS PER MONTH CAN BE DISPOSED OF IN A CHEMICAL LAND— <br /> CTION III — P H Y S I C A L D A T A ( FOR FILL MATERIAL ONLY > FILL WITHOUT BEING DECLARED A HAZARDOUS WASTE. SINCE REGULATIONS VARY CONCERN— <br /> ING THE DISPOSAL OF THESE CHEMICALS CONSULT LOCAL. STATE AND FEDERAL AGENCIES <br /> ILINO POINT(F): 94F SPECIFIC GRAVITY: 0.71 FOR PROPER DISPOSAL METHOD IN YOUR AREA. <br /> AOR PRESSURE(MMHG. ):442 Q20C PERCENT VO_ATILE.BY VOLUME(%): 100 <br /> AOR DENSITY(AIR-1): 2. 56 EVAPORATION RATE( <br /> -1): RAPID <br /> LUBILI TY IN WATER: SLIGHT PH(COMX:ENTRATE): N/A <br /> PH(USE DILUTICN OF ):N/A <br /> PEARANCE & ODOR :A CLEAR. COLORLESS LIQUID WITH A PIERCING AROMATIC ODOR <br /> CTION IV — FIRE AND E XP LOS3 DN DATA FEDERAL HAZARDOUS WASTE NUiBER(S):DOO1 <br /> ASH POINT (METHOD USED):EXTREMELY FLAMMABLE (OSHA FLAME E%TENSION TEST) SECTION VIII — SPECIAL PROTECTION INFORMATION <br /> AMMABLE LIMITS : LEL 27. UEL 48% RESPIRATORY PROTECTION: NONE REQUIRED <br /> TINGUISHINC MEDIA: CO2, FOAM, DRY CHEMICAL VENTILATION: LIMITED USE PRECLUDES VENTILATION PRECAUTIONS. <br /> ECIAL FIRE FICHTING:DIRECT STREAM OF WATER ONTO INTACT CONTAINERS PERSONAL PROTECTIVE EOUI P.:DO NOT SPRAY NEAR FACE OR EVES. <br /> USUAL FIRE WIZARDS: CONTAINERS MAY BURST IF EXPOSED TO /EAT ABOVE 120F. NONE <br /> CTION V — HEALTH HAZARD DATA SECTION IX — S P E C I A L P R E C A U T I O N S <br /> SYMPTOMS <br /> .IN; CAN CAUSE IRRITATION UPON PROLONGED CONTACT. PRECAUTIONS TO BE TAKEN WHEN HANDLING AND STORING: <br /> ES: CAN BE IRRITATING UPON CONTACT. <br /> HALE:CAN CAUSE DIZZINESS AND NAUSEA UPON PROLONGED EXPOSURE. STORE BELOW 12OF AWAY FROM HEAT AND OUT OF DIRECT SUNLIGHT. <br /> IGEST:CAN CAUSE NAUSEA AND VOMITING. DO NOT DISCHARGE AEROSOL IN THE PRESENCE IF OPEN FLAMES. <br /> FIRST AID OTHER PRECAUTIONS: <br /> AN: WASH FROM SKIN WITH SOAP AND WATER. <br /> ES: FLUSH IMMEDIATELY WITH PLENTY OF WATER FOR 15 MINUTES. CONSULT PHYSICIAN. EXTREMELY FLAMMABLE! <br /> HALE:MOVE TO FRESH AIR. ADMINISTER ARTIFICIAL RESPIRATION. IF NEEDED. SEE DOCTOR. KEEP OUT OF REACH OF CHILDREN. <br /> GEST:DO NOT INDUCE VOMITING, SEEK MEDICAL ATTENTION IMMEDIATELY. <br /> V: 400 PPM <br />
The URL can be used to link to this page
Your browser does not support the video tag.