My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
517
>
2300 - Underground Storage Tank Program
>
PR0501895
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2021 9:12:48 AM
Creation date
11/5/2018 10:10:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0501895
PE
2381
FACILITY_ID
FA0005258
FACILITY_NAME
GUARDINO-CRAWFORD CO
STREET_NUMBER
517
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13721410
CURRENT_STATUS
02
SITE_LOCATION
517 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\517\PR0501895\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/2/2013 8:00:00 AM
QuestysRecordID
143753
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI WATER RESOURCES CONTRC OARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWINP INFORMATION FOR EACH TANK. Qp z <br /> 10 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWALPERMIT Yr5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> W <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: W. — FARM TANK-VES❑ NO W <br /> 1. TANKDESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY (� <br /> A. OWNERSTANKIDN Vk I B. MANUFACTURED BY: Or- <br /> C. <br /> C. YEAR INSTALLED U r-_ D. TANK CAPACITY IN GALLONS: <br /> II. TANK PONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUMC. 1 UNLEADED ❑2 LEADED ❑ 3 DIESEL <br /> F] B.3 CHEMICAL PRODUCT ❑ 4 OIL 1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS j <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.R C.A.S.N. <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&O <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM �INGLE WANED ❑/SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEEUIRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK <br /> MATERIAL F-15 CONCRETE ❑6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑8189%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR F-1i RUBBER UNED ❑2 ALKYD LINING ❑3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING D'>UNLINED ❑95 UNKNOWN � <br /> ❑ )SEINING MATERIAL COMPATIBLE WITH IM%METHANOL4 ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHLBIE WRAP ❑ 2T OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 1 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION1 SINGLE WALLED A U 2 DOUBLEWALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 5 1 VISUAL CHECK P i t INVENTORY RECONCILIATION P 8 3 VAOOSE WELLS P S O ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> ,nl'-1 D 8 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE D S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED)MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS I <br /> INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION k AGENCY M FACILITY ID R TANK ID B <br /> E= I I I I / <br /> CURRENT LOCAL AGENCY FACILITY ID 8 APPROVED BY NAME PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK N PERM IT AMOUNT SURCHARGE AMT. FEE CODE gECEIPTk BY: <br /> FORM B(6-2988) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESS=")-.'; CCPv 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.