My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 3:22:51 PM
Creation date
11/5/2018 10:21:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WF <br /> San Joaquin County 40 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Data: <br /> GEMCO RIPON TRUCK PLAZA INC 1022 E FRONTAGE RD. RIPON March 17. 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days. <br /> Secondary containment testing was scheduled to be pertormed on 6 1X01 Sand a test ren_", <br /> to the EHD. A copy of the test report must be submitted within 30 days of the test. Immediately submit a copy of the <br /> test report to the EHD or schedule this test and provide 48 hours notification to the EHD. <br /> This is a Class II violation. <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 6-29-15 and an inspection report was issued identifying information to be submitted to <br /> hrinn this city loin rmmnlian re Thlc infnrmntinn mwc roruiirAri in ha ci,hrnitl Ari 4n rfavc fmm rereint of tha incnArtinn <br /> report. This information has not been received resulting in a non-compliant status for this facility. An operator that <br /> rwreives an inspection canon shall have 2C. rinds In ciihmit Pcnnncu 0P21 in rindr c a ct alamcn/ rinp.n inntinn <br /> corrective actions taken or proposing corrective actions which will be taken. Ensure that a written response <br /> rinrnmenhnn rnrracliva artinnc taken nr nrnnr,aAd is c,.hunihari ,n,ithm iin rla,rc of rero iv inn an in QnPrIinn rennd RT('. <br /> copy was received at the time of inspection. This was corrected on site. <br /> This is a repeat violation. Class II. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> ivMonitoh Ily lecohus (rnoniiuliny 5ysieni _. . secondary cuniainnieni iesi hepuhis) fuh the 2015 were nui <br /> found on site. These records shall be mair,tclnc c,^, sltc for at least three years. Monitoring records include: (1) date <br /> and lime of all nhunituriny u1 5c <br /> anlpiiny, (2) nluniiwiny equipment caiibla0un and nlainienane heculus, (3)le5uiis of <br /> any visual observations; (4) results of sample analysis performed a tab or in the field, (5) logs of all readings of gauges <br /> of Whet nlumiminy equipmeni, yluunu waiel eievaiiuns, u1 oiihel tesi hesuiis, (6) hesuiis of invenimy heauinys anu <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> siie anu 5ubntii copies iv We EHD. Submit plouf of culretiiun to the EHD. <br /> 11115 is a repeat violation, Cia55 ii. <br /> 201j CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> The designated operator employ, vas not performed. The designated operator shall train <br /> facility employees for which he or she is responsible in the proper operation and maintenance of the UST system once <br /> every 12 months. The training shall include, but is not limited to. <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee s role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact persons) for emergencies and monitoring equipment alarms <br /> nsure that employees have been trained by the designated operator, maintain the list on site, and submit a copy ¢ <br /> training records to the EHD. This was corrected on site. <br /> This is a repeat violation. Class H. <br /> Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.