My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 3:22:51 PM
Creation date
11/5/2018 10:30:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\BILLING 2010-2015.PDF
QuestysFileName
BILLING 2010-2015
QuestysRecordDate
11/30/2017 8:57:54 PM
QuestysRecordID
3740259
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLED PROGRAM CONSOLIDATED FORM J <br /> �./ UNDERGROUND STORAGE TANK Y <br /> MONITORING PLAN (Page 2 of 2) <br /> VL UNDER DISPENSER CONTAINMENT(UDC)MONITORING . Sft <br /> tt1r.rIUDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 4o-5w <br /> pt I.CONTINUOUS ELECTRONIC MONITORING ❑ 2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE <br /> ❑4.NO DISPENSERS ❑99.OTHER IS <br /> PANEL MANUFACTURER: 490'53 MODEL �j <br /> -TL-5 us°C — r0 90-57 _ 49o-sa <br /> 4 <br /> LEAK SENSOR MANUFAC['URER: ee I MODEL M(S): �q <br /> a YES ❑It.NO 490.59 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMSHUTDOWN <br /> �,a YES [I b.NO °9060' <br /> P <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. �,a YES ❑b.NO <br /> 49061 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER a YES ❑b.NO 4906 <br /> 990633 <br /> 2.UDC CONSTRUCFION Is t1.SINGLE-WALLED ❑2.DOUBLE-WALLED <br /> 99a-Ms <br /> IF DOUBLE WALLED: <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: [11.LI UID [12,PRESSURE ❑3.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT'OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS EJa YES ❑b.NO 49°'0+0 <br /> VII,PERIODIC SYSTEM TESTING <br /> LJ 1. ELD TESTING: THIS FACILITY HAS BEEN NOTiFLED BY THE STATE WATER RESOURCES CONTROL DO ARD THAT ENHANCED 49o-Os. <br /> LEAK TE N=0 MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 3 CCR 2644.1) <br /> J.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. °� <br /> .SPILL BUCKETS ARE TESTED ANNUALLY. 49007 <br /> VIIL RECORDKEEPING <br /> The following monitoring/maintemance records are kept for this facility: <br /> �KAlann logs 4906s, 0 Visual Inspection Records 4906sb ❑Tank integrity testing results 49a6ae <br /> ❑SIR testing results(and supporting documentation records). 49MM ❑ Tank gauging results(and supporting documentation records). 49068e <br /> MATO Testing results(and supporting documentation records).490 w ❑ Corrosion Protection 60-day logs 49oeea <br /> CK Equipment maintenance and calibration records. 490 ssh <br /> DL TRAINING <br /> ❑Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 490696 <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)s9 % <br /> OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)4906x <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490.696 <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 49o-Ox <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: `HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"49o09r <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"49069, <br /> ❑ OTHER(Specify):m6w,n <br /> JR This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST system annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> ➢ The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> ➢ Names of contact person(s)for emergencies and monitoring alarms.4w7o <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.49 71 <br /> 61eieOl J ITIAj - Pl ek 0 qs�b <br /> XI.PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that 1)the daily/routine UST monitoring activities and maintenance of UST leak detcc im equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained property. <br /> The followin persons)are respo ible for perS'owning the monitoring and equipmeml maintenance: <br /> NAME 490-n TITLE L5!A.I 490-79 <br /> NAME 490-74 TITLE 490.75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br /> conditions that mad follow-up action. <br /> XII.OWNEWOPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the inf r matio¢.provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE r 49x76 - DATE: I ' a9un <br /> JC1K\N0. <br /> I T to p).A R nl ive ofOwnv ___ <br /> APPLICANT NAME(print): 49a78 APPLICANT TITLE: °90-79 <br /> UPCF UST-D(122007)314 <br />
The URL can be used to link to this page
Your browser does not support the video tag.