My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 3:22:51 PM
Creation date
11/5/2018 10:30:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\BILLING 2010-2015.PDF
QuestysFileName
BILLING 2010-2015
QuestysRecordDate
11/30/2017 8:57:54 PM
QuestysRecordID
3740259
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NUN", lSgUnCGs <br /> $TATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY I NEW PERMIT 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM 2 INTERIM PERMIT 4 AMENDED PERMIT <br /> 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br /> DEA OR FACILITY NAME WHERE TANK IS INSTALLED: j 1 fmc—o T"C K �L Z <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.# l B. MANUFACTURED BY: VA/K-,/pl,�/h1 <br /> C. DATE INSTALLED(MOIDAYNEAR) /'j V_A o" D. TANK CAPACITY IN GALLONS', -7` SQA <br /> 11.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A � 1 MOTOR VEHICLE FUEL 4 OIL B. 0 ❑ is REGULAR UNLEADED 3 DIESEL ❑ 6 AVIATION GAS <br /> F72 PETROLEUM 80 EMPTY 1 PRODUCT ❑ 1b PREMIUM UNLEADED [_] 4 GASAHOL ❑ 7 METHANOL <br /> 1c MIOGRADE UNLEADED F-] 5 JET FUEL � 8 M55 <br /> 3 CHEMICAL PRODUCT 95 UNKNOWN 2 WASTE 2 LEADED E:1 99 OTHER(DESCRIBE IN ITEM D.BELOM <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.tl' <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF }❑ 1 DOUBLE WALL 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT a 99 OTHER <br /> B. TANK 1 BARE STEEL 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL 5 CONCRETE 6 POLYVINYL CHLORIDE E] 7 ALUMINUM ❑ H 100% METHANOL COMPATIBLE W1FRP <br /> (Primary Tank) ❑ 9 BRONZE 10 GALVANIZED STEEL 95 UNKNOWN 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED 2 ALKYD LINING 3 EPDXY LINING 4 PHENOLIC LINING <br /> LINING OR F] 5 GLASS LINING 6 UNLINED ❑ 95 NKNOWN 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES NO_ <br /> D.EXTERIOR 1 POLYETHYLENE WRAP 2 COATING VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION a 91 NONE eD ��91 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,etc. SPILL CONTAINMENT I ALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) Lj Cm) <br /> DROP TUBE YES NO STRIKER PLATE YESy NO DISPENSER CONTAINMENT YES NO <br /> N. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH TF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 1001/6 METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> MECHANICAL LINE LEAN 2 LINE TIGHTNESS 3 CONTINUOUS INTERSTITIAL 4 ELECTRONIC LINE 5 AUTOMATIC PUMP 99 OTHER <br /> D. LEAK DETECTION jllfDETECTOR ❑ TESTING MONITORING ❑ LEAK DETECTOR SHUTI)M" El <br /> V.TANK LEAK DETECTION <br /> El 1 VISUAL CHECK ❑ 2 MANUAL RECONCILIATION MONITORING <br /> 3 MAO ORING 4 AUTOMATGAUGING MONITORING <br /> TANK O 5 GROUND MONITORINGTER 6' TETANK <br /> STING <br /> 7 CONTINUMONITOR U INTERSTITIAL 8 SIR ❑ 9 WEEKLY MANUAL O 10 STINGY TANK 95 UNKNOWN 99 OTHER <br /> TANV1.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST USED(MOiDAYNR) J� 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH Y <br /> J" A- SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER P LTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE//�� <br /> (PPINTEoa SIGNATURE) M(K67 t- LL( t q N�rj <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW (J' T V <br /> COUNTY# JURISDICTION# FACILITY 4 TANK# <br /> STATE I.D.# <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PE=RMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLAN. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) <br />