My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
816
>
2300 - Underground Storage Tank Program
>
PR0231470
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 2:09:29 PM
Creation date
11/5/2018 10:33:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231470
PE
2361
FACILITY_ID
FA0003911
FACILITY_NAME
VAN DE POL ENTERPRISES INC
STREET_NUMBER
816
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102010
CURRENT_STATUS
01
SITE_LOCATION
816 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\816\PR0231470\COMPLIANCE INFO\2016 - PRESENT.PDF
QuestysFileName
2016 - PRESENT
QuestysRecordDate
9/22/2016 7:01:58 PM
QuestysRecordID
3006673
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Califomia95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.siaov.orD/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENTE 6ES INC 816 E FRONTAGE RD, RIPON -ary 31. 2017 <br /> On Site Records <br /> 204 CCR 27120 Current monitoring plan approved by the EHD not found on site u V u R u COS <br /> 205 CCR 2712(1) Failure to have an approved UST response plan available onsite in V ❑R ❑COS <br /> 206 CCR 2712 Failure to comply with USToperating permit conditions o V ❑R ❑COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment ❑V in R ❑COS <br /> 208 CCR 2650(e) Failed to notify the EHD of a reportable unauthorized release ❑V ❑R ❑COS <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed ❑V ❑R ❑COS <br /> 210 CCR 2715(e) Designated operator monthly Inspection reports not maintained on site for at least 12 months ■V ■R ❑COS <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept ❑V ❑R o COS <br /> 212 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD ❑V oft o COS <br /> 213 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually Inspected at least dally or log not kept ❑V ❑R ❑COS <br /> 214 HSC 25281.5(b)(3) 1 Unburied emergency generator fuel piping not visually inspected at least monthly or log kept ❑V ❑R ❑COS <br /> UST System Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills ❑V ❑R D COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) ❑V ❑R ❑COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) in V ❑R ❑COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) o V o R in COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained ❑V ❑R in COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity ■V ❑R in COS <br /> 307 j CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained ❑V ❑R ❑COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm ❑V ❑R o COS <br /> 309 CCR 2636(f)(1) Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product o V o R ❑COS <br /> 310 CCR 2636(1)(5) Piping is not fall-safe outside UDCs or fails to stop flow of product at dispenser Inside UDCs o V ❑R ❑COS <br /> 311 CCR 2638(a),26410) Failed to properly program or operate leak detection equipment ❑V o R ❑COS <br /> 312 CCR 2638(f) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced ❑V ❑R ❑COS <br /> 313 HSC 25290.1,25290.2, Failure to construct,operate,and maintain primary containment as product-tight ■V ❑R ❑COS <br /> 25291 <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not tight n m oCOS <br /> 25291 <br /> 315 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) ■V ❑R ■COS <br /> 316 HSC 25290.1(0), Secondary containment not constructed to prevent water intrusion(after Jul 2003) ❑V ❑R in COS <br /> 25290.2(c3) <br /> 317 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 318 CCR 2636(1)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V ❑R o COS <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep 0 empty ❑V ❑R ❑COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden o V in R ❑COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V ❑R ❑COS <br /> FA0003911 PRO231470 SC001 01/31/1017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.