My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO 2004-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 4:46:00 PM
Creation date
11/5/2018 11:19:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2006
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\COMPLIANCE INFO 2004-2006.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
41ar 24 05 10: 53a MikDotten (209) 533-2650 P. 1 <br /> i <br /> Alltech <br /> 17759 Buttercup Circle, Sonora, CA 95370 <br /> Phone: 209-532-7320; Fax: 209-533-2650 <br /> California Contractor 623541 A-Haz <br /> Afike@AlltechPetro.com �Fal <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: Costco # 038 Stockton Date of Testing/Servicing: March 22,2005 <br /> Facility Address:1616 W. Hammer Lane, Stockton CA <br /> Facility Contact Person: Rich Medeiros(Ser. Sta. Supervisor); Facility Phone: (209)478-2040 <br /> LIA: San Joaquon Health; Inspector: Michelle Le;LIA Phone: (209) 468-9847; LIA Fax: (209) 468-3433 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> B. Invento of Equipment Tested/Certified: <br /> Tank ID:Regular 1 Tank Tank ID:Regular 2 Tank <br /> N ht-Tank Gauging Probe. Model:Mag 1 N In-Tank Gauging Probe. Model:Mag 1 <br /> ®Annular Space Sensor. Model:Single-Float Brine ®Annular Space Sensor. Model:Single-Float Brine <br /> N Brine level:6.25" Adjusted to: N Brine level:7"" Adjusted to: <br /> ®Piping Sump Sensor(s). Model:Discriminating Sensor ®Piping Sump Sensor(s). Model:Discriminating Sensor <br /> ®Fill sump sensor(s). Model:Discriminating Sensor ®Fill Sump Sensm(s). Model:Discriminating Sensor <br /> N Electronic Line leak Detector. Model:PLLD N Electronic Line Leak Detector. Model:PLLD <br /> ®Tank Overfill/High-Level Sensor. Madel:V.R Audible N Tank Overfill/High-Level Sensor. Model:V-R Audible <br /> N Fillspill Bucket Tested: ®Pass ❑Fail N Fillspill Bucket Tested: ®Pass []Fail <br /> ® Fire extinguishers inspected and tagged: NOK ❑Not OK N Fire extinguishers inspected and tagged: NOK ❑Not OK <br /> Tank ID:Premimn Tank: Tank ID:None <br /> N In-Tank Gauging Probe. Model:Mag 1 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space Sensor. Model:Single-Float Brine ❑Annular Space Sensor, Model: <br /> N Brine level:7.5" Adjusted to: ElBrine level: 11Adjusted to: <br /> ®Piping Sump sensor(s). Model:Discriminating Sensor ❑Piping Sump Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model:Discriminating Sensor ❑Fill Sump Sensor(s). Model: <br /> ®Electronic Line Leak Detector. Model:PLLD ❑ Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model:V-R Audible ❑Tank Overfill/High-Level Sensor. Model: <br /> ® <br /> Fillspill Bucket Tested ®Pass []Fail ❑Fillspill Bucket Tested: ❑Pass []Fail <br /> ® Fire exon uishers cted and ed: NOK ❑Not OK ❑ Fire exon fishers in ected and to ed []OK ❑Not OK <br /> Dispenser D} 1&2 N Sump:®Dry❑Water❑Product Dispenser ID:3&4 N Sump:®Dry❑Water❑Product <br /> ®Dispenser Containment Sensor(s). Model:Non-Discriminating N Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) N Shear Valve(s) (Functional test) <br /> ® Fire a 'sher ins ted and to : NOK ❑Not OK ® Fireexon 'skier ted and ed: ®OK ❑Nat OK <br /> Dispenser ID:5&6 N Sump:®Dry❑Water❑Product Dispenser ID:7&8 N Sump: NDry[]Water❑Product <br /> ®Dispenser Containment Sensor(s). Model:Non-Discriminating N Dispenser Containment Senscr(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) N Shear Valve(s) (Functional test) <br /> ® Fire er in cted and tagged. ®OK ❑Not OK ® Fire extinguisher inspected and ed: NOK []Not OK <br /> Dispenser ID:9&10 N Sump:NDry❑Water❑Product Dispenser ID: 11&12 N sump:NDry❑Water❑Product <br /> N Dispenser Containment Sensor(s). Model:Non-Discriminating ®Dispenser Contaimnent Sensor(s). Model:Non-Discrim ating <br /> ®Shear Valves) (Functional test) N Shear Valve(s) (Functional test) <br /> ® Fire extin 'sher= cted and ed: NOK ❑Not OK ® Fire extin isher' ted and ted NOK []Not OK <br /> Dispenser ID: ❑Sump:[]Dry[]Water[-]Product Dispenser 1D: ❑Stump:❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s) (Functional test) ❑Shcar Valve(s) (Functional test) <br /> ❑ Fire 'skier j ected and tagged: ❑OK []Not OK ❑ Fre extin rusher ins ted and!Med: ❑OK ❑Not OK <br /> G Certification-I certify that the equipment identified In this document ass impeded/serviced in accordance with the manufacturers'guidelines. Attached <br /> to this Certification n a Plot Plan showing the layout of monitoring equipment For anyequipment capable of generating Tach reports,I have also attached <br /> a copy of the mport ®System set-up ®Alarmlarm_Mstory report <br /> Technician: 14"9 Y J�LrIJW— Mike Dotten,California Contractor 623541 A-Haz <br /> Certification:Veeder-Root:006-05-0789;Level 4. <br />
The URL can be used to link to this page
Your browser does not support the video tag.