COMPLIANCE INFO 2004-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO 2004-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 4:46:00 PM
Creation date
11/5/2018 11:19:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2006
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\COMPLIANCE INFO 2004-2006.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page B of/0 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested 0 <br /> Test Method Developed By: ❑Sump Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: <br /> Fill Sum F11 Sump# ? Fill Sump# t Fill Sum #IM <br /> Sump Diameter: ^ ti <br /> Sump Depth: S C� <br /> Height from Tank Top to Top of �7 21 "' 2 ,Z <br /> Highest Piping Penetration: 22 <br /> Height from Tank Top to Lowest2 z t� 3 z� <br /> Electrical Penetration: J <br /> Condition of sump prior to /^ `` <br /> testing: ce Deo I1 <br /> Portion of Sump Tested Above highest Above highest Above highest Above highest <br /> netratlon netration Penetration nehatlon <br /> SumpMaterial: 1 <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(RO: 0l Z 2. lei" Z . /y rp <br /> Test End Time: % <br /> Final Reading(RF): 180 <br /> Test Duration: Z.Ay'.✓ ti <br /> Chane in Reading(RF-R,): . 00'040.0 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: Pass ❑Fail 6,Pass ❑Fail A Pass D Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? X Yes D No X Yes D No X Yes ❑No X Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is 0 Yes D No X NA ❑Yes ❑No X NA ❑Yes ❑No X NA ❑Yes ❑No X NA <br /> detected? <br /> Was sensor removed for testing? X Yes D No DNA X Yes ❑No DNA X Yes ❑No DNA X Yes D No DNA <br /> Was sensor properly replaced and X_Yes D No DNA X Yes D No DNA X_Yes ❑No [INA X Yes ❑No DNA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> SB 989 6 no. test <br /> WO#: 040920-117 <br /> Costco#38 <br /> 1616 E. Hammer Lane &vJest <br /> Stockton, CA 95210 <br />