COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 11:13:49 AM
Creation date
11/5/2018 11:20:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
202
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: <br /> Costco Wholesale#38 Phone:Facility Date: <br /> Facility Address: (209)47 <br /> March 01, 2018 <br /> 1616 E Hammer Ln, Stockton, CA 95210 CERS ID: <br /> 10146199 <br /> Inspection Contact: Title: Phone: <br /> Raj Mohan Supervisor <br /> Inspection Type: (209)475-9180 <br /> Program: <br /> ROUTINE INSPECTION-Operating Permit 2371 -UST FACILITY-1702 COMPLIANT <br /> Consent For: Consent Given By: <br /> O Ins ection O Photos 0 Sam les Raj Mohan, Supervisor <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Isaac Anderson 06/15/2018 Kaylynn Rammell 06/15/2018 <br /> Service Technician Manufacturers Training: <br /> VR, 09/26/18;VMI, 04/07/19 <br /> CCR=CalHomia Cade of Regulations HSC=ii and Safety Cade CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees o V o R o COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system o V QR o COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted o V o R o COS <br /> 104 CCR 2711 UST operating permit application for fatality and tank information not submitted or current o V in R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan o V a R o COS <br /> 2634(d <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan o V o R o COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V o R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prorto conducting testing o V o R3CO S <br /> 109 CCR 2637 Failed to test secondary containment o V o RS <br /> 110CCR 2637(e) Failed to submit secondary containment test report within 30 days o V o R n COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V o R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V o R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days <br /> mV o R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br /> OV OR o COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change vein 30 days o V OR o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V o R o COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br /> QV o R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to Conduct proper tests o V o R o COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V a R o COB <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification o V o R COOS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V OR o COS <br /> 122 CCR 26316) Failure to submit and maintain UST system component statement of compatibility for substance stored o V o R o COS <br /> On Site Records <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records o V o R o COS <br /> 202 CCR 2712(b) Failed to maintain Cathodic protection test records on site for at least 6 1/2 years c V OR o COS <br /> FA0001705 PRO518624 Scoot 03/012018 <br /> EHD 23-01 Rev.09122/16 Page t of 4 Underground Storage Tank Program OIR <br /> 9171 9690 0935 0159 9051 78 <br />
The URL can be used to link to this page
Your browser does not support the video tag.