My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3518
>
2300 - Underground Storage Tank Program
>
PR0232337
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 3:56:08 PM
Creation date
11/5/2018 11:26:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232337
PE
2361
FACILITY_ID
FA0003599
FACILITY_NAME
ARCO AM PM #5569
STREET_NUMBER
3518
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
13002001
CURRENT_STATUS
02
SITE_LOCATION
3518 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\3518\PR0232337\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/9/2013 8:00:00 AM
QuestysRecordID
162229
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNL' WATER RESOURCES CONTRO' 90ARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROLRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION ° <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. Z <br /> to <br /> MARK ONLY 1 NEW PERMIT ❑3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM F-12 INTERIM PERMIT ❑ 44AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE/ ❑8 TANK REMOVED O/ <br /> 7N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: E,. N/g' E� yt/6, S /�/ FARM TANK-YES❑ NO µ <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY h <br /> A. OWNERS TANK IDM aj B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: 2 � <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,C LETE ITEM D. <br /> A. [:4'1'MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. Erl UNLEADED ❑2 LEADED ❑3 DIESEL <br /> F-] 3 CHEMICAL PRODUCT ❑4 OIL 1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑80 EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,a D <br /> A. TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑4 SECONDARY COMAINMENF ❑99 OTHER <br /> ❑ 1 STEELIIRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/RBERGUSS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑ B 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> ❑ I RUBBER UNED ❑2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> C. INTERIOR <br /> ❑ <br /> LINING 5 GLASS LINING F-16 UNLINED ❑ 95 UNKNOWN ' <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 10D%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ I POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IFABOVEGROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLADW/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S I VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3VADOSEWELLS P 8 4 ELECTRONIC MONITOR P 6 5 GROUNDWATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 6 7 PRESSURETESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MONR) 2. ESTIMATED GUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? [:]YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 6 SIGNATURE) DATE 1i <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERINR ieliviI DATE <br /> CHECKN PERMITAMOUNT SURCHARGE AMT. FEE CODE RECEIPT0 BY: <br /> FORM B(6-29-m) THIS FORM MUST BE ACCOMPANIED V A FACILITY/SITE APPLICATION, FORM 'A',UNLESS l4liff FORMA' HAS BEEN FILED - <br />
The URL can be used to link to this page
Your browser does not support the video tag.