My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3518
>
2300 - Underground Storage Tank Program
>
PR0232337
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 3:56:08 PM
Creation date
11/5/2018 11:26:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232337
PE
2361
FACILITY_ID
FA0003599
FACILITY_NAME
ARCO AM PM #5569
STREET_NUMBER
3518
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
13002001
CURRENT_STATUS
02
SITE_LOCATION
3518 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\3518\PR0232337\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/9/2013 8:00:00 AM
QuestysRecordID
162229
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL PnARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGr-rAM <br /> a <br /> TANK TANK PERMIT APPLICATION INFORMATION ` <br /> �CCOMMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ANEW PERMIT ❑3 RENEWAL PERMIT 5CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSEOTAN <br /> ONE ITEM F--] 2 INTERIM PERMIT F-14 AMENDEDPERMIT 616 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED IN <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ARCO AM/PM MinimaTt - Facility # FARM TANK-YES❑ NO ® l <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY O <br /> A. OWNERS TANK ID# NO. 1 B. MANUFACTURED BY: Xerxes <br /> C. YEAR INSTALLED 1988 D. TANK CAPACITY IN GALLONS: 12,000 <br /> N <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. ul <br /> A. ® 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. © 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑4 OIL X❑ i PRODUCT ❑ 4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS v <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> .III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,S D <br /> A.TYPE OF ® i DOUBLE WALLED ❑3 SINGLE WALLED WITH EXIENIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEUIRON ❑ 2 STAINLESS STEEL ®3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑ 5 CONCRETE ❑6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑B 100%MEIHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR F-11 RUBBER LINED E]2 ALKYD LINING F-13 EPDXY LINING F-] 4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ® 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP '❑2 TAR OR ASPHALT ❑3 VINYL WRAP ®4 FIBERGLASSREINFORCEDPLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION p 02 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A to 2 DOUBLE WALLED A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELARON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A 0 <br /> 4 FIBERGLASS PIPE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLADW/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> _f P 8 1 VISUAL CHECK P 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS(!)S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTI NG P S 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? E]YES E] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> P. B. TobinG <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> o '�' 3 3 0 1C) 10 1 / <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BYA M PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE / PERMIT EXPIRATION DATE <br /> CHECK# MRMITAMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(3-7-BB) THIS FORM MUST BE ACCOMPANIbmfflPWACILITY/SRE APPLICATION, FORM 'A',UNLES FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.