My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1995 TANK TOP UPGRADE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3518
>
2300 - Underground Storage Tank Program
>
PR0232337
>
INSTALL_1995 TANK TOP UPGRADE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 4:22:38 PM
Creation date
11/5/2018 11:29:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1995 TANK TOP UPGRADE
RECORD_ID
PR0232337
PE
2361
FACILITY_ID
FA0003599
FACILITY_NAME
ARCO AM PM #5569
STREET_NUMBER
3518
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
13002001
CURRENT_STATUS
02
SITE_LOCATION
3518 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\3518\PR0232337\TANK TOP UPGRADE 1995.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UST SYSTEM PRINTSET INFORMATION <br />1. Four complete sets of plans (To include specification sheets and/or equipment brochures if not on file). <br />2. Plans drawn to scale in non -erasable print. <br />3. Plot plan to show location and nuiber of tanks. <br />4. Tank cross-sectional diagram included on prints submitted. <br />5. Detail of tank, piping system, excavation and cover. <br />6. Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Subchapter 16, <br />Article 3, Sec. 2631 (r) & 26351 <br />7. Verification of product compatibility with the tank(s), piping, monitoring <br />device(s), epoxy or silicone glues, etc. (Section 2635 (b) (2)] <br />8. Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. (Section 2635 (b) (5)] <br />9. Tightness Test (NFPA 30) is required on both primary (10) and secondary (20) containment systems before covering. <br />[Section 2635 (b) (6) & (7)] <br />10. Double walled tanks using pressure or vacuum testing to monitor the anular space. [Section 2635 (b) (7)) <br />11. NFPA 329 "Precision Test" required upon completion of installation with tank in operating condition. Test results to <br />be submitted directly to PHS/EHD from the testing company or owner of facility. [Health & Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (g)) <br />nIU M V Vvic1-4nrt rrnr,Vc Tn Romain <br />TANK # <br /># <br />N <br />R <br /># <br /># <br />CAPACITY <br />12,000 <br />12,000 <br />MANUFACTURER <br />Xerxe.5 <br />XerxesXerxes <br />COMPOSITION <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />MODEL <br />PRODUCT <br />Re lar <br />Super <br />Mid— ade <br />CORROSION PROTECTION <br />N/A <br />N A <br />N/A <br />U.L. LISTED <br />Yes <br />Yes <br />Yes <br />COMPATIBILITY WITH 100% <br />METHANOL <br />Yes <br />Yes <br />Yes <br />13. TANK(s) TO BE INSTALLED PIPING ONLY Fxisting Tanks To Remain <br />_ A. Steel -clad with fiberglass reinforced plastic. <br />B. Holiday test required immediately before "setting" tank(s) (35,000 - 40,000 volts). [Section 2635 (b) Ml <br />C. Fiberglass [Sections 2635 (3) and 2631 (p)3 <br />(1) Striker plate dimensions and materials. <br />_ (2) Striker plate under sit accessible openings. <br />(3) Installation Instructions require an air test and soap bubble test prior to installation. <br />Non -clad steel tank [Section 2635 (b)] <br />_ (1) Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />etc.). <br />(2) Approved by a corrosion engineer or N.A.C.E. technician. <br />(3) Document stating inspection method and frequency (minimum semi-annual inspection requirement). <br />F1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.