UST SYSTEM PRINTSET INFORMATION <br />1. Four complete sets of plans (To include specification sheets and/or equipment brochures if not on file). <br />2. Plans drawn to scale in non -erasable print. <br />3. Plot plan to show location and nuiber of tanks. <br />4. Tank cross-sectional diagram included on prints submitted. <br />5. Detail of tank, piping system, excavation and cover. <br />6. Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Subchapter 16, <br />Article 3, Sec. 2631 (r) & 26351 <br />7. Verification of product compatibility with the tank(s), piping, monitoring <br />device(s), epoxy or silicone glues, etc. (Section 2635 (b) (2)] <br />8. Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. (Section 2635 (b) (5)] <br />9. Tightness Test (NFPA 30) is required on both primary (10) and secondary (20) containment systems before covering. <br />[Section 2635 (b) (6) & (7)] <br />10. Double walled tanks using pressure or vacuum testing to monitor the anular space. [Section 2635 (b) (7)) <br />11. NFPA 329 "Precision Test" required upon completion of installation with tank in operating condition. Test results to <br />be submitted directly to PHS/EHD from the testing company or owner of facility. [Health & Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (g)) <br />nIU M V Vvic1-4nrt rrnr,Vc Tn Romain <br />TANK # <br /># <br />N <br />R <br /># <br /># <br />CAPACITY <br />12,000 <br />12,000 <br />MANUFACTURER <br />Xerxe.5 <br />XerxesXerxes <br />COMPOSITION <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />MODEL <br />PRODUCT <br />Re lar <br />Super <br />Mid— ade <br />CORROSION PROTECTION <br />N/A <br />N A <br />N/A <br />U.L. LISTED <br />Yes <br />Yes <br />Yes <br />COMPATIBILITY WITH 100% <br />METHANOL <br />Yes <br />Yes <br />Yes <br />13. TANK(s) TO BE INSTALLED PIPING ONLY Fxisting Tanks To Remain <br />_ A. Steel -clad with fiberglass reinforced plastic. <br />B. Holiday test required immediately before "setting" tank(s) (35,000 - 40,000 volts). [Section 2635 (b) Ml <br />C. Fiberglass [Sections 2635 (3) and 2631 (p)3 <br />(1) Striker plate dimensions and materials. <br />_ (2) Striker plate under sit accessible openings. <br />(3) Installation Instructions require an air test and soap bubble test prior to installation. <br />Non -clad steel tank [Section 2635 (b)] <br />_ (1) Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />etc.). <br />(2) Approved by a corrosion engineer or N.A.C.E. technician. <br />(3) Document stating inspection method and frequency (minimum semi-annual inspection requirement). <br />F1 <br />