INSTALL_2000 TANK TOP UPGRADE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3518
>
2300 - Underground Storage Tank Program
>
PR0232337
>
INSTALL_2000 TANK TOP UPGRADE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 4:30:07 PM
Creation date
11/5/2018 11:31:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2000 TANK TOP UPGRADE
RECORD_ID
PR0232337
PE
2361
FACILITY_ID
FA0003599
FACILITY_NAME
ARCO AM PM #5569
STREET_NUMBER
3518
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
13002001
CURRENT_STATUS
02
SITE_LOCATION
3518 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\3518\PR0232337\TANK TOP UPGRADE 2000.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11-3®-1999 2t65PM FROM <br /> PUBLIC HEALTH SERVICtS '°rt <br /> SANJOAQUIIN COUNTY �' A m <br /> ENVIRONMENTAL HEALTH r)MSION <br /> Ernest M. Fujimoto, M. D.,M.F.H., Acting Health Officer * <br /> 304 E. Weber Ave.,Third Floor • P. O. Box 388 • Stockton, CA 95201-0388 <br /> 2091468-3420 <br /> TO: INSTALLERS AND OWN"r,RS OF NEW UNDERGROUND STORAGE TANKS <br /> San Joaquin County Public Health Services-Envimnmentat Health Division(PHS-EHD) has establ o�monllowingoring guidelines <br /> to assist you in the completion of your construction project. The guidelines <br /> in�specify �s� n <br /> necessary to complete our review of your proposed underground <br /> 1. C�IBMt'TT�SS <br /> INSTALLATION: <br /> a. Submit 3 complete sets of drawings illustrating the locations of all existing-, and proposed <br /> structures, including- existing UST(s), in non-erasable print to PHS-ice, upon approval, <br /> one set will be retained by PHS-EHD and the other two will be returned. <br /> D. Include equipment and material specification sheets and Manufacturer's broctrsres describing <br /> field testing procedures, operating and monitoring systems and listing numbers or other <br /> evidence of a nationally recognized resting organization approval. All proposed leak <br /> detection methods and equipment must meet the requirements specified in 40 CFR 280.40 <br /> and have been reviewed by the State Water Resources Controi Board Staff. <br /> c. All interstitial rnonimrs must perform according to manufacturer's standards. and must be <br /> tested annually in accordance with section 2630 (d), California Code of Regulations (CCR), <br /> Title 23 Waters, Division 3. Chapter 16. <br /> d. Tnclude a detailed monitoring and response plan in accordance with section 2632 (d) (1) & <br /> (2), CCR, Title 23 waters, Division 3, Chapter 16. <br /> e. The plans should include a cross sectional diagram of the tank and piping system including <br /> secondary containment, overflow protection equipment, and extension or all pipes and/or <br /> ports from below grade to finish grade. <br /> F. Submit a completed "PHS-EHD Service Request" form and the State Water Resources <br /> Control Board "Facility Permit (A)" and "Tank Permit (B)" application forms_ <br /> SITE MITIGATION: <br /> a. in the event contamination is observed, confirmed or suspected as a result of a leaking UST <br /> system it is the responsibility of the owner or operator to submit a workplan to PHS-EBD <br /> Site Mitigation Visit prior to initiating any assessment or remediation activities. To Minimize <br /> delays, a Corrective Action Plan may be submitted concurrent with tank CIO= or <br /> insmilation plans. Address one copy of the Corrective Action Plan to the Site Mitigation <br /> Unit for review. For funher assistance contact the Sim Mitigation Unit at (209) 468-3450. <br /> ,i OiVlSion of Sin Joagvin County Heeitn C.:re Scn';C" <br /> Post-it'Fax Note 7671 oa+e 1.. -� ; ► <br /> 7 1rn Prwn sea �VI'h <br /> co vwt. c° a<+ID <br /> tnone a anwre x <br />
The URL can be used to link to this page
Your browser does not support the video tag.