11-39-1999 2:b7PM f=ROP, . <br /> 4, Rer)1mtFn INSPEfTT' ONS <br /> vote: The connector's PHS-EHD approved plans of the UST installation shall be retained at the <br /> job sate and trust be shover, to the PHS-EHD inspector upon request. in addition, the <br /> applicable fire department shall approve the UST installation prior to commencement of <br /> work <br /> ,all appointments for inspections must be made at least 48 hours in advance_ Below are the <br /> minimum required inspections: <br /> a. Before installation, the tank shall be tested for tightness at the insmiiation site in accordance <br /> with the manufacnlrer's written.guidelines. If there are no guidelines, the primary and <br /> secondary containment shall be tested for tightness with air pressure between 3 and 5 pounds <br /> per-square inch. In lieu of a pressure rest, a vacuum expressed in inches of mercury in the <br /> interstitial space of the w-condwy containment, is acceptable. The pressure (or vacuum in <br /> the interstitial space) shall be tnainrained for a minimum of 30 minutes. <br /> b. All new primary pipin,g and secondary containment systems shall be tested for tightness aper <br /> nstallation in accordance with manufacturer's guidelines. Primary pressurized piping shall <br /> be hydrostatically tested at 150 petcear of design operating pressure or pneumatically at 110 <br /> Percent of design operating pressure. If the calculated rest pressure for pressurized piping is <br /> less than 40 psi, 40 psi shall be used as the test pressure. The pressure shall be Tainiained <br /> for a minimus of 30 minutes and all joints shall be soap rested. If there are no <br /> manufacturer's guidelines, secondary containment systems shall be tested using an applicable <br /> method specified in an industry code or engineering standard. <br /> C. All tires other tltatr pressure piping shall be pressure tested at not less than 3 p.s.i. and not <br /> more than 5 p.s.i_ for a minimum of 30 minutes and soap tested white under pressure. <br /> d. Containment sumps shall pass a 24 hour hydrostatic leak test. <br /> e. The spill container shall be shown to be capable of draining liquid 'back into the fuel tanks. <br /> f. The monitoring system shall pass a functional test The functional test shall consist of the <br /> activation of the alarm via all monitoring probeslsensors. <br /> Final inspection and approval to operate will be granted after the above requirements are <br /> satisfied and a hard copy of the tank integrity test (as required by Section 2635 (a) (5)] is <br /> submitted to the inspector at the site. <br /> If you aced further assistance, or wish to schedule an appointment to discuss the plan review <br /> or field inspection, piease contact our Underground Storage Tank Staff at (209) =68-342''. <br /> z <br />