My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2000 PIPING REMOVAL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3518
>
2300 - Underground Storage Tank Program
>
PR0232337
>
REMOVAL_2000 PIPING REMOVAL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 4:55:57 PM
Creation date
11/5/2018 11:34:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2000 PIPING REMOVAL
RECORD_ID
PR0232337
PE
2361
FACILITY_ID
FA0003599
FACILITY_NAME
ARCO AM PM #5569
STREET_NUMBER
3518
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
13002001
CURRENT_STATUS
02
SITE_LOCATION
3518 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\3518\PR0232337\PIPING REMOVAL 2000.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC HVALTH SERVI1 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DIVISION <br /> Karen Furst, M.D., M.P.H., Health Officer <br /> 4CiFp PN\ <br /> 304 East Weber Avenue, Third Floor • Stockton, C 52 <br /> 209/465-3420 <br /> APPLICATION FOR PERMIT TO CLOSE <br /> UNDERGROUND STORAGE TANKS STORING HAZARDOUS MATERIALS <br /> 1. GENERAL INSTRUCTIONS: <br /> Ipl 1. Submit all information in triplicate. Answer all questions, leaving no blanks. One copy will be returned <br /> 4J' to the applicant with comments.. II <br /> Include a detailed C 9$p A 9eparatII <br /> e)eet of paper, showing the location of the tanks(s), piping, <br /> streets, adjacent properties (north toward the top of the page), nearby septic tanks, leachfields, water <br /> wells, buildings, underground public utility lines (including water, sanitary sewer and storm sewer), and <br /> distance of piping from tank to dispensers. If underground utilities are not included on the site map, you <br /> ust state in writing that USA Dig will be contacted prior to excavation activities.CO'N 3omplete page 3, "Application for Underground Storage Tank Closure Permit". Not : Sampling- <br /> firm shall be an independent third party from the contractor. <br /> 4./ Complete page 9, "Authorization to Release". This form must be signed and dated by the <br /> (( pWNER/OPERATOR of the facility. <br /> d14, 5. 1/ /Submit the appropriate fees and complete page 11, the "Underground Storage Tank Program Fee <br /> Worksheet". <br /> l 6.� Complete all questions on page 10, the Public Health Services-Environmental Health Division (PHS- <br /> EHD) "Underground Storage Tank Disposition Tracking Record", except those requiring a signature <br /> and date of tank removal. The holder of the permit shall be responsible for ensuring that this form is <br /> completed and returned to PHS-EHD within 30 days of the tank removal. ,s Wyf J4iyµp�:h <br /> 7. Submit a "Site Health & Safety Plan" as an addendum to this application, to address all potential <br /> hazards for this specific job site. Refer to the Site Safety Plan Guidance Document for specifics. <br /> �jl 8 If facility is located outside of the city limits, submit a "Backfill Excavation Certificate" as required by <br /> IV the County of San Joaquin Building Department and the incorporated City Building Departments, <br /> /// pursuant to the Uniform Building Code STD 70-11. <br /> 9. Obtain a "Grading and Excavation Permit" from the City of Tracy Building Division prior to PHS- <br /> I✓/ EHD approval of the closure plan. <br /> 10. r The maximum review time for Closure Plans is 15 working days from receipt of the adequately <br /> completed plan. If gross deficiencies are identified, an addendum will be required with a 578.00/hour <br /> fee and the review will begin on the date of resubmittal. <br /> co 11. Submit verification of the fire permit from the appropriate fire district at the removal inspection. <br /> 12. Advance inspection notice of at least 48 hours is required by PHS-EHD. <br /> [ <br /> 13. Submit Contingency Plan for over-excavation at time of UST removal (if planning to over-excavate). <br /> See "III. SITE MITIGATION" on Page 2. <br /> EH 23 046 (Revised 08/13/99) Page 1 <br /> A Division of San Joaquin County Health Care Services <br />