3/4" CONDUIT FCR PUMP POWER "---'— - --" --""-".,3AJ/NCIIGN CO DUIT To FILL SUMP 90 MECHANICAL'LINE LEAK CEIECTOR"•+—V'�. ��"'�_�" aM ii <br /> BOX <br /> i0 ELECT. PANEL - 1 PER TANK •-------- f" CONDUIT TO INTRINSICALLY <br /> SAFE CUTTER AT MONITOR 59 42" MANHOLE ------ 3/4" EXPLOSION + ' <br /> CONTROL PANEL (1 PER TANK) PEA GRAVEL PROOF 45' ELBOW <br /> 2" BLACK IRON NIPPLE - 24x 1'-O"x 1'-0" STYROFOAM <br /> 61 2" BALL VALVE— --- 2" BLACK IRON ELL ,. , <br /> \ EXPLOSION PROOF ' <br /> / \ JUNCTION BOX <br /> 3" PVC PIPE OPEN AT BOTTOM, ` t Z x " r <br /> 41 F.R.P, CONTAINMENT SUMP 14 <br /> NOTE,. ` FUEL-GUARD <br /> 36' MULTIPORT MANHOLE STEEL RISERS MUST BE 16' O.C. TRUE (90 MECHANICAL LINE \ - / FILTER SEPARATOR 62 04 <br /> AND PLUMB. USE PHIL-PTE FILL-VAPOR RISER J - I — N CONTAINMENT SUMP REDUCER, <br /> 22' FUEL TANK MANWAY _ <br /> SUPPORT BRACKET 81600 AS REQUIRED. LEAK DETECTOR 2" BLACK IRON NIPPLE 56 TURBINE PUMP FIBERGLASS REDUCER ON THE OUTSIDE <br /> TO ENSURE WATER TIGHTNESS <br /> PIPE CAP WITH HOLE <br /> PENETRATION BOOT � 1 2" NIPPLE <br /> 14 48"o F,R.P. CONTAINMENT SUMP - <br /> O 1 60 (F BALL VALVE <br /> 2" BLACK IRON ELL FOR CONTROL WIRES <br /> 37 36" MULTIPORT MANHOLE ( ( (FULL PORT) 1 JUNCTION BOX <br /> SUMP PENETRATION BOOT 12 CONTAINMENT SUMP -- nl /^ 2" NIPPLE (EXPLOSION PROOF) <br /> 10 3" 45' GALVANIZEDf / \ 1/2" BALL VALVE 1 <br /> STEEL ELBOW 3/4" CONDUIT TO ELECT. <br /> n ^ / 1/2" BRAIDED STAINLESS STEEL PANEL (PUMP POWER) <br /> 2" F.R,P, VENT LINE / \ 3" F R.P VAPOR LINE / \ / > TUBING DRAIN LINE 1" CONDUIT TO SEAL OFF <br /> 2'x 1'-0"x l'-0" / / \ 2"x 1'-0"x 1'-0' / / \ \ \ f--1/2" BLACK IRON STREET ELL INTRINSICALLY SAFE <br /> 56 TURBINE PUMP \ GUTTER AT MONITOR _ I <br /> STYROFOAM �/ - \ STYROFOAM \ O / <br /> CONTROL PANEL 1 3" PVC PIPE OPEN AT <br /> \ / ` < \ / \ 2' E4"B FLEXIBLE r_ I <br /> 1' J" BELLxMALE F.R.P. 65 I BOTTOM. <br /> 2" BELLxMALE F.R.P. THREACED ADAPTOR —rte— FILL \ / s- / O 3/4" CONDUIT TO 1 <br /> THREADED ADAPTOR �— / —� O l 2" SCH. 40 FRP. FILL SUMP J-BOX 2" FRP BELL x MALE <br /> BELL x MALE THREADED ADAPTOR <br /> \ 3" x 12" FLEXIBLE \ 61 2" BALL VALVE THREADED ADAPTER 0 0 PENETRATION .BOOT <br /> 2" x 18' FLEXIBLE 42 \ \ / 43 CONNECTOR -- --- \ \ / 2" BLACK IRIN4 9D' ELL - (FOR CONDUIT) 3"x2 800T'W'"' 74 <br /> CONNECTOR V / s/ / v' 2" SCH, 40 FRP. l TEST PORT .O <br /> MALE SWIVEL%FEMALE TLM / �M <br /> /'�I�— 3" STEEL UNION <br /> _ _ ___ NOTE ON RED JACKET TURBINE, TRANSDUCER 45' ELBOW PENETRATION BOOT <br /> {—{-1 OF TANK —� } � 1— OF TANK SCREWS INTO SWIFT CHECK ON NRBINE HEAD. 3"z2° BOOT WITH TEST PORT 74 <br /> PENETRATION 0® \V ) 1 .3" FRP 419 58 2"x18" MxF FLEXIBLE <br /> BOOT ^ \ O CONNECTOR FIBERGLASS CONTAINMENT SUMP RE TANK <br /> PLAN 2" FRP 18 MANUFACTURERS DO <br /> NOT <br /> TSEXCFED 1 WATER TIGHTNESS <br /> ESSDE D OUT TO INSURE <br /> 2" F,R.P. VAPOR LINE \ 2" F.R.P. VENT LINE \ / ^ - <br /> / \ SUMP PENETRATION / \ 1/4" BRAIDED STAINLESS STEEL 1/2" BALL VALVE J ` PIPE IN 3" FRP OO <br /> 2" BELLxMALE F,R,P. < — 0' - TUBING VENT LINE--- BEND RADIUS. 2" FRP PRODUCT 18 19 <br /> O BOOT 1/2" BLACK IRON NIPPLE 4" STEEL TUBE RISER SECONDARY CONT, <br /> THREADED ADAPTOR / 2" BELLxMALE F.R.P. \ \ / / 59 42" MANHOLE PRIMED & WRAPPED PIPE <br /> 1/2" TO 1/4" REDUCING STREET ELL - DISCRIMINATING SENSOR 88 <br /> \ / THREADED ADAPTOR / <br /> 2" x 78" FLEXIBLE 56 TURBINE PUMP <br /> CONNECTOR / \ / � \ / 2"x 1'-0'x 1'-0" STYROFOAM 4' N,P,T, <br /> MALE SWIVEL%FEMALE 42 \v/ \v/ 42 MALE 1SMVELxF18MAL ONNECTO \y / / \ r 4" N.P.T. PLUGGED <br /> 2" 90' GALVANIZED — OPW 233VM-6045 <br /> - ELEVATION <br /> CPW 233VM STEEL ELBOW EXTRACTOR FITTING , . TURBINE WITHOUT <br /> -4422 FILTER <br /> ' <br /> EXTRACTOR FITTING . <br /> 1. Z <br /> 2" 90' GALVANIZED <br /> STEEL ELBOW SUPREME, PLUS UNLEADED PLAN REGULAR UNLEADED EXPLOSION PROOF <br /> IN <br /> - JUNCTION BOX r <br /> CONTAINMENT SUMP REDUCER, - <br /> T 3/4" EXPLOSION FIBERGLASS REDUCER ON THE OUTSIDE <br /> PROOF ELBOW TO ENSURE WATER TIGHTNESS <br /> SEAL OFF <br /> I _ 2 1/2"FROM TOP OF <br /> SPILL BUCKET 65 2"x24" FLEXIBLE i OF N H L SLEEVE <br /> O TOP <br /> 2'N24`_FLE MALE BY I - 2" BLACK IRON 90' ELL (MAN HOLE) - - - _—== <br /> ' MALE SWIVEL <br /> 3/4" CONDUIT TO j O ' - J C y4/2" o <br /> FILL SUMP JUNCTION 1 --- <br /> BOX FUEL-GUARD \OVERLAP FINISHED <br /> 1" CONDUIT TO O FILTER SEPARATOR b2 GRAPE <br /> 'INTRINSICALLY SAFE - .a <br /> GUTTER AT MONITOR i 0 —1/2" BLACK IRON ELL <br /> 36' MULTI PORT MANHOLE WITH <br /> 37 LIQUID TIGHT FILL BOX OPER TANK)NTROL - SUMP <br /> 12" BALL VALVE 61O SHEILD <br /> — JUNCTION BOX (EXPLOSION PROOF) 3/4" CONDUIT FOR j TANK BUNG WITH 1/2" PORT TOP OF F,R.P. <br /> 28 29 VAPOR RECOVERY ADAPTOR SEAL OFF EPUMP LECT POWER TO CONTAINMENT SUMP <br /> AND <br /> ELECT. <br /> TANK FIBERGLASS CONTAINMENT SUMP TO TANK - - <br /> TUM PROBE MOUNTING FITTING 84 - COLLAR INSIDE AND OUT TO INSURE WATERTIGHTNESS - <br /> - <br /> ® SUMP SHIELD 4" CAP ON RISER ® 1/2" BRAIDED STAINLESS STEELDISCRIMINATING SENSOR - TUBING DRAIN LINE <br /> 3" PVC PIPE OPEN AT ELEVATION FILTER MOUNTNC NATES: <br /> JUNCTION BOX BOTTOM. ATTACH TO STEEL RISER BRACKET FOR 4' PIPE 64 1. RISER PIPES MUST BE 16" O.C. TRUE & PLUMB. a <br /> 31 API COLORED REFLECTOR WITH UNISTRUT FOR SUPPORT TURBINE WITH FILTER O USE PHIL-TITE FILL-VAPOR SUPPORT BRACKET 01600 AS REQUIRED. <br /> PIPE CAP WITH HOLE FOR <br /> 2 1/2" FROM TOP OF'" CONTROL INITIS — — 2. ALL OVERLAPS AND DIMENSIONS SHALL BE HELD TRUE' <br /> TO INSURE WATER TIGHT SEALS. <br /> SPILL BUCKET TO TOP ° e. <br /> OF STEEL SLEEVE ° a o ' <br /> (MANHOLE) .d . . .' ° ° d 3 TURBINE SPILL BUCKET DETAIL <br /> do <br /> PEA GRAVEL - - <br /> 2"x 1'-0"x V-0" STYROFOAM <br /> 1 36" MULTIPORT MANHOLE WITH 37 'NSTA ATI 1N INSTRUCTIONS- <br /> 14 CONTAINMENT SUMP REDUCER, ) LIQUID TIGHT FILL BOX A PULL STRING MAY BE IN THE TANK. INSTALL A <br /> FIBERGLASS REDUCER ON THE OUTSIDE SUMP SHIELD 38 NEW PULL STRING IF THE STRING MISSING, LOST <br /> TO ENSURE WATER TIGHTNESS I O OR BROKEN, THE PULL STRING IS NOT A TANK <br /> MANUFACTURER WARRANTY ITEM. INSTALL THE <br /> 07 4"-300j COUPLING I INTERSTITIAL MONITOR AT THE BOTTOM CENTERLINE TANK PLUG - TORQUE TO ISOLATION CAP <br /> m 3/4" CONDUIT FROM ANNULAR SPACE —COLOR CODED PRODUCT COLLAR 30 OF THE FRP TANK. INSERT FISH TAPE THROUGH THE -300 FT.-LBS. PRIOR TO <br /> MONITOR JUNCTION BOX I ANNULAR SPACE, TAG BOTH THE PULL STRING TO THE - INSTALLING ISOLATION CAP TANK FITTING <br /> ti SUMP PENETRATION BOOT O 4" TOP SEAL ADAPTOR AND CAP 26 27 PROBE SIGNAL CABLE AT 12.5 FT. PLUS THE BURIAL <br /> Z: j (FOR CONDUIT 0 <br /> DEPTH. ATTACH THE PULL STRING TO THE PROBE AND G.E. SCS 1202 COMPRESSION RING <br /> E 4" SCH. 40 GALVANIZED RISER i TO THE FISH TAPE AND PULL THE PROBE INTO TANK. JUNCTION BOX SILICONE SEALEANT <br /> N PRIMED AND WRAPPED — — 3/4" CONDUIT TO TURBINE SUMP JUNCTION BOX WHEN THE TAGS ON THE SIGNAL CABLE AND THE PULL ISOLATION <br /> 7 I - 2 1/2" FROM TOP CF STRING MATCH, THE PROBE IS AT THE BOTTOM 18" MANHOLE W TANK FITTING <br /> 4" SCH. 40 GALVANIZED STEEL RISER 34 BASE <br /> 20 2' F,R.P. VENT LINE PRIMED & 'WRAPPED ° ° SPILL BUCKET 70 TOP REMAIN LIN EPLLACE FOR AFUTUEE ACCESSIBILITY.IS 10 / <br /> I ! a OF STEEL SLEEVE SECURED LID O BASE ' <br /> 2"x18" FLEX CONNECTOR ° (MANHOLE) WATER TIGHT <br /> 1 MALE SWIVEL/FEMALE 42 ° ° <br /> � N I < 6 � MONITOR PLUG <br /> tl UNUSED FITTING <br /> 'p - MONITOR TAG & <br /> 2' F.R.P. PHASE It VAPOR RETURN (3" F.R.P. AT PEA GRAVEL <br /> REGULAR UNLEADED) 2"x I'-O"x V-O" STYROFOAM ,° 'I I "' HOLDER <br /> d, }g OR 40 FtBERCLASS CONTAINMENT SUMPCONTAINMENT SUMP REDUCER <br /> - - <br /> , �t <br /> p TO TANK COLLAR INSIDE AND OUTSIDE FIBERGLASS REDUCER ON THE OUTSIDE II 1' MAXIMUM <br /> TO INSURE WATER TIGHTNESS SUMP PENETRATION BOOT 0® TO ENSURE WATER TIGHTNESS 4" SCH. 40 NIPPLE ^ - <br /> 2" 45' F.R.P, 4"-300p COUPLING (GALVANIZED) 1 <br /> EXTRACTOR FITTING 2" BELLxMALE F.RP, v 4'-300# COUPLING TANK FITTING ISOLATION DETAIL <br /> m . - - <br /> 22" TANK MANWAY THREADED ADAPTOR CONTAINMENT SUMP (GALVANIZED) NO SCALE " <br /> d Q <br /> 4" ALUMINUM FILL TUBE 33 Chevron sS.A, Inc. iChevron") owns the electronic <br /> rights to the design in the herein described fueling <br /> 3/4" o CONDUIT <br /> 0. " P A system as embodied in an ton 'able or electronic medium of ex ressi n including II building <br /> 3 VC PIPE OPEN T es y g p o g a il dm <br /> W - TO FILL SUMP J-BOK <br /> ly, BOTTOM. ATTACH R STEEL RISER designs, architectural plops and drawings. The copyrighted material includes the overall farm as weu os <br /> WITH UNISTRUT FOR SUPPORT � 4" SCH. 40 GALVANIZED RISER the arrangement and composition of spaces and elements in the design, but does not Induce Ind vldual. <br /> 41 3" 98% FLOAT VENT/VAPOR _ PRIMED AND WRAPPED standard features. Anyone who wishes to copy, distribute or sell this drawing or any derivative works <br /> VALVE —� DISCRIMINATING SENSOR 88 based hereon most have the prior written consent of Chevron, except for copies mode for the sole <br /> —.4" SCH, 40 GALVANIZED Purpose of preparing construction drawings for Chevron branded facilities and all such copies shall be <br /> returned to Chevron upon request. - { <br /> PRODUCT FLOAT 84 TANK FITTING - PIPE RISER - Fn <br /> �- - ' PRIMED &.WRAPPED Q1995 Chevron U.S.A, Inc. All rights reserved. <br /> 1. PERPENOICULAR PENETRATIONS OF CONTAINMENT WATER FLOAT FIBERGLASS CONTAINMENT SUMP The drawings, calculations, and any specific reference to equipment, materials or components, 11l'jy't1 <br /> SUMPS PREFERRED. 20' MAXIMUM ALLOWABLE TO TANK COLLAR INSIDE AND OUT if included herein, are generic and not designed for site specific applications. Chevron does not warronl <br /> PENETRATION ANGLE. I. BOTTOM LOCKING NUT - TO INSURE WATER TIGHTNESS 4" SCH. 40 GALVANIZED or guaranty the accuracy, completeness, merchantability, intended use or opplicobility of such draWngs,' - <br /> PIPE RISER calculations, and any referenced equipment, materials or components, to the requirements or <br /> 2. USE SUMP PENETRATION BOOTS AT ALL I - SEAL AT PLATE CONNECTION PRIMED & WRAPPED needs of your site or local area. Consult a registered architect or professional engineer to determine <br /> PENETRATIONS OF SUMP, 22" TANK MANWAY any site 6 TANK FITTING al applicable ific design.federaal, state applicability. <br /> local statutes, lrulesuiland9regulati regulations <br /> dict requirements and any and <br /> 3.' ALL JUNCTION BOXES ARE TO BE PLACED WITHIN _ __ which may affect your site, <br /> 1'-0" OF THE TOP OF SUMP. <br /> STEEL PLATE AT TANK BOTTOM 0® Chevron does not provide these services, Q <br /> ti. <br /> POSITIVE SHUT OFF DEVICEt W <br /> / TLIFONE AND RLL DETAILS <br /> Y <br /> ELEVATION <br /> caPAc TYlg <br /> T 95% OF TANK <br /> a NOTES i <br /> r�/. .pp <br /> �r/�r11 1. PERPENDICULAR PENETRATIONS OF CONTAINMENT Che9-427.5 <br /> ✓1 <br /> PENETRATION RED, 20' MAXIMUM ALLOWABLE SIDE VIEW AT TANK BOTTOM <br /> N Marketing 2905 W. BENJAMIN HOLT DR. <br /> - 2. USE SUMP PENETRATION BOOTS AT ALL STOCKTON, CA. T <br /> o PENETRATIONS OF SUMP. �.•+"' <br /> U 3, ALL JUNCTION BOXES ARE TO BE PLACED WITHIN WRE INSTALLATION CABLE RBV�Of18 <br /> LL -0' OF THE TOP OF SUMP. B6 - - 7/ <br /> / i' .. SCALE- 114'-1'-0' DAT'Er 1CSEP96 <br /> SENSOR <br /> OR CH. APP, `? <br /> 6 FILL, TLM, VAPOR AND VENT 5 FILL DETAIL '4 ANNULAR SPACE MONITOR 5C <br /> 8235.21 <br /> FOR REFERENCE ONLY, EXISTING TANKS TO REMAIN <br /> OCT 0 9 1996 <br />